SkyCiv文档

SkyCiv 软件指南 — 教程, 使用指南和技术文章

AS 柔性端板连接设计 4100

To design a flexible end plate connection to AS 4100, you follow the beam end shear from the beam web, through the fillet welds and the end plate, into the bolts and the support. That means checking the welds to the beam web, the bolts in shear and in bearing, the end plate in shear and block shear, and the beam web along the weld. The detailing limits on pitch, gauge, edge distance and plate depth come first, because the end plate only behaves as a simple connection if it is thin and has a wide enough gauge to flex.

本页从头到尾介绍一个示例: 一个 460 UB 82.1 beam framing into the flange of a 310 加州大学 158 柱子, with a design shear of 150 千牛, eight M20 8.8/S bolts and a 10 mm AS/NZS 3678 Gr.250 end plate, designed to AS 4100:2020. 每个方程都用它的数字写出来, in the same order as the calculation report that the SkyCiv Connection Design 模块为其生成. It uses the same beam, column and design shear as the web side plate example, so you can compare the two connections check by check. The scope and conventions of the AS 4100 module are on the design of steel connections using AS 4100:2020 页.

What is a flexible end plate connection?

A flexible end plate connection is a thin plate fillet welded across the end of the beam web in the shop and bolted to the supporting member on site. The plate is shallower than the beam and is welded to the web only, not to the flanges, so the beam end can rotate as the plate bends between its two bolt lines. That is what makes it a simple connection: it carries the beam end shear and almost no end moment.

It is a popular shear connection in Australian building frames because the beam arrives on site already fitted with its plate, and the site work is bolting to a flat face. The beam has to be cut to an accurate length, as there is no slack between the plate and the support. In the AS 4100 module it sits beside the web side plate, which is welded to the support and bolted to the beam, and the single and double angle cleats, which are bolted on both sides.

In this example the end plate has two vertical lines of four bolts at a 140 mm gauge, bolted to the flange of the column.

Flexible end plate elevation: 460 UB 82.1 beam with a 10 mm end plate bolted with M20 8.8/S bolts to a 310 加州大学 158 法兰

示例连接的标高. The end plate is welded to the beam web with a 6 mm E49XX fillet weld on both sides.

A-A部分: PL 10x240x325 AS/NZS 3678 Gr.250 end plate with eight M20 8.8/S bolts at 75 毫米间距和 140 mm gauge

A-A部分, looking at the end plate. Four rows at 75 毫米间距, two columns at a 140 mm gauge, 和 50 mm edge distances all round.

SkyCiv 连接设计装配选项卡: 柔性端板 240 x 325 X 10 毫米, AS / NZS 3678 Gr.250, shown in the 3D view

SkyCiv 连接设计中的相同连接, with the end plate selected on the Assembly tab.

Flexible end plate connection design: 步骤一目了然

  1. Check the connection detailing limits: 沥青, gauge, edge distances and end plate depth.
  2. 检查最小角焊缝尺寸, then the design capacity of the weld to the beam web.
  3. Check the design capacity of the bolt group in shear.
  4. Check the bolt group in bearing on the end plate and on the column flange.
  5. Check the end plate in shear.
  6. Check the end plate in block shear.
  7. Check the beam web in shear along the weld.
  8. Check the supported member (光束) 剪切力.

本示例的设计输入

The design code is AS 4100:2020, with section properties from the Australian section database. The yield strength of each part follows its grade and thickness: 300 MPa for the beam, 280 MPa for the column with its 25 mm flange, 和 260 MPa for the 10 mm AS/NZS 3678 Gr.250 end plate.

物品象征值
Design shear (design action effect)[mathin] V^{*} [mathin]150 千牛
Beam460 UB 82.1, AS / NZS 3679.1 Gr.300
波束深度[mathin] d_{bm} [mathin]460 毫米
梁腹板厚度[mathin] t_{wb} [mathin]9.9 毫米
梁翼缘宽度 / 厚度[mathin] b_{fb},\ t_{fb} [mathin]191 毫米 / 16 毫米
光束产率 / 抗拉强度[mathin] f_{yb},\ f_{ub} [mathin]300 兆帕 / 440 兆帕
柱310 加州大学 158, AS / NZS 3679.1 Gr.300
柱深 / 腹板厚度[mathin] d_{sup},\ t_{ws} [mathin]327 毫米 / 15.7 毫米
柱翼缘宽度 / 厚度[mathin] b_{fs},\ t_{fs} [mathin]311 毫米 / 25 毫米
柱产量 / 抗拉强度[mathin] f_{ys},\ f_{us} [mathin]280 兆帕 / 440 兆帕
弹性模量[mathin] E [mathin]200000 兆帕
物品象征值
端板PL 10 X 240 X 325, AS / NZS 3678 Gr.250
板宽 / 深度 / 厚度[mathin] b_{i},\ d_{i},\ t_{i} [mathin]240 毫米 / 325 毫米 / 10 毫米
板材产量 / 抗拉强度[mathin] f_{yp},\ f_{up} [mathin]260 兆帕 / 410 兆帕
螺栓M20 8.8/S, threads included in the shear plane
螺栓直径 / minimum tensile strength[mathin] d_{fw},\ f_{uf} [mathin]20 毫米 / 830 兆帕
Holes in end plate and column flange[mathin] d_{h} [mathin]标称, 22 毫米
Weld to beam web6 mm fillet both sides, E49XX, SP
焊缝尺寸 / weld metal strength[mathin] t_{ww},\ f_{uw} [mathin]6 毫米 / 490 兆帕
几何象征值
螺栓排 / row pitch[mathin] n_{p},\ s_{p} [mathin]4 / 75 毫米
螺栓柱 / column pitch (gauge)[mathin] n_{g},\ s_{g} [mathin]2 / 140 毫米
端板垂直边距[mathin] l_{ev\_ep} [mathin]50 毫米
端板水平边距[mathin] l_{eh\_ep} [mathin]50 毫米

Unlike a web side plate, the end plate has no bolt group eccentricity in this design. The bolts are in the face of the support, so the module takes the design shear at the centroid of the bolt group.

Design shear (作为 4100 条款 9.1.4)

作为 4100 条款 9.1.4 sets a minimum design action for a simple connection. 设计剪力不小于以下较小者 0.15 times the design shear capacity of the beam and 40 千牛. The beam capacity is the uncoped web shear capacity, which Step 8 uses again:

[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (460\ \text{mm}) \times (9.9\ \text{mm}) = 737.75\ \text{kN} [math]

[math] V^{*}_{min} = \min\left( 0.15\, \phi V_{vo},\ 40\ \text{kN} \right) = \min\left( 0.15 \times (737.75\ \text{kN}),\ 40\ \text{kN} \right) = 40\ \text{kN} [math]

[math] V^{*} = \max\left( V^{*},\ V^{*}_{min} \right) = \max\left( 150\ \text{kN},\ 40\ \text{kN} \right) = 150\ \text{kN} [math]

该 150 kN entered is above the minimum, so it is the design action effect for every check below.

步骤 1: 连接详细限制 (作为 4100 条款 9.5)

The bolt layout has to be buildable and has to match the assumptions behind the capacity equations. For an end plate the gauge matters twice: it must be wide enough to clear the beam web and its welds and to let the plate flex, and not so wide that the plate stops behaving as a tied pair of bolt lines.

The minimum pitch is [mathin] 2.5\, d_{f} = 2.5 \times 20\ \text{mm} = 50\ \text{mm} [mathin] (条款 9.5.1). The minimum edge distance for an M20 bolt is 35 毫米, [mathin] 1.75\, d_{f} [mathin] 从表 9.5.2. The maximum edge distance is 12 板厚的倍数, [mathin] 12 \times 10\ \text{mm} = 120\ \text{mm} [mathin], and the maximum column pitch is 15 板厚的倍数, [mathin] 15 \times 10\ \text{mm} = 150\ \text{mm} [mathin]. The other limits in the table, 包括 61.9 mm minimum column pitch, 的 88.7 mm minimum gauge on the column flange and the 230 mm minimum and 405.2 mm maximum end plate depths, are the limits the module applies for this beam and support. 柱翼缘上的边距是 311 mm flange outside the 140 mm gauge, [mathin] (311 – 140) / 2 = 85.5\ \text{mm} [mathin].

详细限制限制 (毫米)实际的 (毫米)直流电结果
Minimum bolt row pitch50.00075.0000.667通过
Maximum bolt row pitch140.00075.0000.536通过
Minimum bolt column pitch61.900140.0000.442通过
Maximum bolt column pitch150.000140.0000.933通过
Minimum vertical edge distance on end plate35.00050.0000.700通过
Minimum horizontal edge distance on end plate35.00050.0000.700通过
Minimum horizontal edge distance on column flange35.00085.5000.409通过
Minimum bolt gauge on column flange88.700140.0000.634通过
Minimum end plate depth230.000325.0000.708通过
Maximum end plate depth405.200325.0000.802通过
Maximum edge distance120.00050.0000.417通过

对于最小限制,该比率是实际值的限制, 对于最大值来说,它实际上超出了限制. The governing row is the bolt column pitch, 的 140 mm gauge against the 150 mm maximum:

[math] DCR = \frac{140\ \text{mm}}{150\ \text{mm}} = 0.93333 [math]

DCR = 0.933 ≤ 1.0, 行

A wide gauge is what you want on a flexible end plate, so a ratio close to this limit is not a problem. It is the opposite end of the range that would make the plate stiff.

步骤 2: Weld to the supported member (作为 4100 Clauses 9.6.3.10, 9.7.1)

The end plate is welded to the beam web with a fillet weld on each side, running the full depth of the plate. These two welds carry the whole design shear out of the beam web. The report checks the minimum weld size first, then the weld capacity.

最小角焊缝尺寸 (桌子 9.6.3.2)

对于所连接的零件来说太小的角焊缝冷却得太快并且可能破裂, so AS 4100 桌子 9.6.3.2 sets a minimum size for the thicker part, not exceeding the thinner part. Here the thicker part is the 10 mm end plate, which gives a minimum of 4 毫米:

[math] t_{ww} = 6\ \text{mm} \ge t_{w,min} = 4\ \text{mm} [math]

DCR = 4 毫米 / 6 毫米= 0.667 ≤ 1.0, 行

The summary of the report lists this as its own row. It compares weld sizes, not a design action with a capacity.

焊接能力

The weld is Structural Purpose (SP), so the capacity factor is 0.8 从表 3.4. The design capacity per unit length of an equal-leg fillet weld, with a throat of the leg size over the square root of 2, 和 [mathin] k_{r,weld} = 1 [mathin] because it is not a long welded lap joint:

[math] \phi v_{w} = \phi\, 0.6\, f_{uw}\, \frac{\sqrt{2}}{2}\, t_{ww}\, k_{r,weld} [math]

[math] \phi v_{w} = (0.8) \times 0.6 \times (490\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (6\ \text{mm}) \times (1) = 0.99787\ \text{kN/mm} [math]

The weld runs the full end plate depth, [mathin] d_{i} = 325\ \text{mm} [mathin], on both sides of the web:

[math] \phi V_{w} = 2\, d_{i}\, \phi v_{w} = 2 \times (325\ \text{mm}) \times (0.99787\ \text{kN/mm}) = 648.61\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{w} = 648.61\ \text{kN} [math]

DCR = 150 千牛 / 648.61 kN = 0.231 ≤ 1.0, 行

步骤 3: Design capacity of the bolt group in shear (作为 4100 Clauses 9.2.2.1, 9.3.1)

The threads are in the single shear plane, so the core area is used: [mathin] n_{n} = 1,\ A_{c} = 225\ \text{mm}^{2} [mathin] 和 [mathin] n_{x} = 0 [mathin]. The capacity factor for a bolt in shear is 0.8, and the reduction factors [mathin] k_{rd} [mathin] 和 [mathin] k_{r,bolt} [mathin] are both 1:

[math] \phi V_{f} = \phi\, 0.62\, f_{uf}\, k_{rd}\, k_{r,bolt}\, \left( n_{n} A_{c} + n_{x} A_{o} \right) [math]

[math] \phi V_{f} = (0.8) \times 0.62 \times (830\ \text{MPa}) \times (1) \times (1) \times \left( (1)(225\ \text{mm}^{2}) + (0)(314.16\ \text{mm}^{2}) \right) = 92.628\ \text{kN} [math]

For an end plate the module takes the load at the centroid of the bolt group, so every bolt carries an equal share and the group capacity is the bolt capacity times the number of bolts, [mathin] n_{b} = 8 [mathin]:

[math] \phi V_{df} = n_{b}\, \phi V_{f} = (8) \times (92.628\ \text{kN}) = 741.02\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{df} = 741.02\ \text{kN} [math]

DCR = 150 千牛 / 741.02 kN = 0.202 ≤ 1.0, 行

Compare this with the web side plate example, where the same eight bolts give 430.69 kN because the group is loaded at a 107.5 mm eccentricity.

步骤 4: Bolt group in bearing on the end plate and the support (作为 4100 条款 9.2.2.4)

Each bolt bears on its hole in the end plate and in the column flange. A ply can fail by crushing at the hole, 上限为 [mathin] 3.2\, d_{fw}\, t_{p}\, f_{up} [mathin], or by tearing out in the direction of the force, which depends on [mathin] a_{e} [mathin]. The force is vertical, so the vertical distances govern.

Bearing on the end plate

[mathin] a_{e} [mathin] is the distance from the edge of the hole to the edge of the ply, or to the next hole, 加上螺栓直径的一半. 和 [mathin] d_{h} = 22\ \text{mm} [mathin]:

[math] a_{e1} = l_{ev\_ep} – 0.5\, d_{h} + 0.5\, d_{fw} = (50\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 49\ \text{mm} [math]

[math] a_{e2} = s_{p} – d_{h} + 0.5\, d_{fw} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]

[math] a_{e} = \min\left( a_{e1},\ a_{e2} \right) = \min\left( 49\ \text{mm},\ 63\ \text{mm} \right) = 49\ \text{mm} [math]

The capacity factor for a ply in bearing is 0.9:

[math] \phi V_{b} = \phi \min\left( 3.2\, d_{fw}\, t_{i}\, f_{up},\ a_{e}\, t_{i}\, f_{up} \right) [math]

[math] \phi V_{b,pl} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (10\ \text{mm}) \times (410\ \text{MPa}),\ (49\ \text{mm}) \times (10\ \text{mm}) \times (410\ \text{MPa}) \right) = 180.81\ \text{kN} [math]

Bearing on the column flange

The column runs past the connection, so there is no edge near the bolts in the direction of the force. Only the distance to the next hole applies:

[math] a_{e3} = s_{p} – d_{h} + 0.5\, d_{fw} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]

[math] \phi V_{b,sup} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (25\ \text{mm}) \times (440\ \text{MPa}),\ (63\ \text{mm}) \times (25\ \text{mm}) \times (440\ \text{MPa}) \right) = 623.7\ \text{kN} [math]

Bolt group bearing capacity

The weaker ply per bolt, times the number of bolts:

[math] \phi V_{b} = \min\left( \phi V_{b,pl},\ \phi V_{b,sup} \right) n_{b} = \min\left( 180.81\ \text{kN},\ 623.7\ \text{kN} \right) \times (8) = 1446.5\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{b} = 1446.5\ \text{kN} [math]

DCR = 150 千牛 / 1446.5 kN = 0.104 ≤ 1.0, 行

该 10 mm end plate governs over the 25 mm column flange, and its edge distance term is the smaller one, 所以 50 mm vertical edge distance sets the end plate’s bearing capacity.

步骤 5: End plate in shear (作为 4100 条款 5.11.3)

The design shear passes down the end plate on both sides of the beam web, so the module takes two shear planes, each the full depth and thickness of the plate. A rectangular plate does not carry shear uniformly, 和条款 5.11.3 allows for that with 0.5 fy on the gross area:

[math] \phi V_{v} = 2\, \phi\, 0.5\, f_{yp}\, d_{i}\, t_{i} [math]

[math] \phi V_{v} = 2 \times (0.9) \times 0.5 \times (260\ \text{MPa}) \times (325\ \text{mm}) \times (10\ \text{mm}) = 760.5\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{v} = 760.5\ \text{kN} [math]

DCR = 150 千牛 / 760.5 kN = 0.197 ≤ 1.0, 行

步骤 6: End plate in block shear (作为 4100 条款 9.1.9)

A block of the end plate can tear out around each bolt column: shear down the column of bolts to the bottom edge of the plate, plus tension across to the side edge. There are two such blocks, 梁腹板的每一侧, so the areas are doubled.

受拉净面积, across the two bottom bolts to the side edges:

[math] A_{nt} = \left( 2\, l_{eh\_ep} – d_{h} \right) t_{i} [math]

[math] A_{nt} = \left( 2 \times (50\ \text{mm}) – (22\ \text{mm}) \right) \times (10\ \text{mm}) = 780\ \text{mm}^{2} [math]

剪切总面积和净面积, along both bolt columns:

[math] A_{gv} = 2 \left[ l_{ev\_ep} + (n_{p} – 1)\, s_{p} \right] t_{i} = 2 \times \left[ (50\ \text{mm}) + (4 – 1)(75\ \text{mm}) \right] \times (10\ \text{mm}) = 5500\ \text{mm}^{2} [math]

[math] A_{nv} = 2 \left[ l_{ev\_ep} + (n_{p} – 1)\, s_{p} – (n_{p} – 0.5)\, d_{h} \right] t_{i} = 2 \times \left[ (50\ \text{mm}) + (3)(75\ \text{mm}) – (3.5)(22\ \text{mm}) \right] \times (10\ \text{mm}) = 3960\ \text{mm}^{2} [math]

The tension stress is uniform, 所以 [mathin] k_{bs} = 1 [mathin], and the capacity factor for block shear is 0.75:

[math] \phi R_{bs} = \phi \min\left( 0.6\, f_{up}\, A_{nv} + k_{bs}\, f_{up}\, A_{nt},\ 0.6\, f_{yp}\, A_{gv} + k_{bs}\, f_{up}\, A_{nt} \right) [math]

[math] \phi R_{bs} = (0.75) \times \min\left( 0.6 \times (410)(3960) + (1)(410)(780),\ 0.6 \times (260)(5500) + (1)(410)(780) \right) \times 10^{-3} = 883.35\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi R_{bs} = 883.35\ \text{kN} [math]

DCR = 150 千牛 / 883.35 kN = 0.170 ≤ 1.0, 行

The second term, shear yielding on the gross area plus tension rupture, is the smaller one here.

步骤 7: 受剪梁腹板 (作为 4100 条款 5.11.2)

All of the design shear leaves the beam through the welds to the end plate, so the length of beam web that carries it is the end plate depth, not the full beam depth. The design shear capacity of that strip of web:

[math] \phi V_{w} = \phi\, 0.6\, f_{yb}\, d_{i}\, t_{wb} [math]

[math] \phi V_{w} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (325\ \text{mm}) \times (9.9\ \text{mm}) = 521.24\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{w} = 521.24\ \text{kN} [math]

DCR = 150 千牛 / 521.24 kN = 0.288 ≤ 1.0, 行

这是治理强度检查. A deeper end plate lengthens the welds and raises this capacity directly.

步骤 8: Supported member in shear (作为 4100 条款 5.11.2)

Away from the end plate the whole beam web carries the shear. The beam is uncoped, so the full depth is available. 第一, the web has to be stocky enough to reach shear yield without buckling:

[math] \frac{d_{p}}{t_{w}} = 43.232 \le \frac{82}{\sqrt{f_{y} / 250}} = 74.855 [math]

The web is not slender, so the design shear capacity is the yield capacity of the web:

[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (460\ \text{mm}) \times (9.9\ \text{mm}) = 737.75\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{vo} = 737.75\ \text{kN} [math]

DCR = 150 千牛 / 737.75 kN = 0.203 ≤ 1.0, 行

检查摘要

设计检查Design action effectDesign capacity直流电结果
连接详细限制140 毫米150 毫米0.933通过
Minimum weld size4 毫米6 毫米0.667通过
Weld to supported member150 千牛648.615 千牛0.231通过
剪切螺栓组150 千牛741.024 千牛0.202通过
Bolt group in bearing on end plate and support150 千牛1446.48 千牛0.104通过
End plate in shear150 千牛760.5 千牛0.197通过
End plate in block shear150 千牛883.35 千牛0.170通过
受剪梁腹板150 千牛521.235 千牛0.288通过
Supported member in shear150 千牛737.748 千牛0.203通过

连接通过了每项检查. 最高比例, 0.933, does not compare a design action with a capacity: it is the 140 mm gauge against the 150 mm maximum column pitch for a 10 mm plate. The minimum weld size row, 一个 4 mm minimum against the 6 mm weld, 是 0.667. 强度检查, the beam web in shear along the end plate governs at 0.288, followed by the weld at 0.231. The end plate in shear follows at 0.197. The bolts have a large margin at this load, because the bolt group is loaded at its centroid.

Auto Design is available for the flexible end plate in the AS 4100 模块. 它改变了螺栓, end plate and welds until every check passes, and keeps your members and design actions as entered. 见 汽车设计 page for the AS 4100 preferences it works to.

如果检查失败要更改什么

  • 构造限制: adjust the pitch, gauge, edge distances or end plate depth to the limits in Step 1. If the gauge is too narrow for the column flange, widen it, and if it is over the maximum column pitch, use a thicker plate or a narrower gauge.
  • Minimum weld size: increase the fillet weld to the Table 9.6.3.2 minimum for the thicker part.
  • 焊接能力: 增加焊缝尺寸, use a stronger electrode, or make the end plate deeper to lengthen the welds.
  • 剪切螺栓组: 添加螺栓行, 使用更大的螺栓, or a higher bolt grade.
  • Bolt bearing: increase the vertical edge distance or the pitch, or use a thicker end plate. If the support governs, 添加螺栓.
  • End plate in shear or block shear: make the end plate deeper, or use a higher grade. A thicker plate also works but makes the connection stiffer, so prefer a deeper plate.
  • 受剪梁腹板: make the end plate deeper, which lengthens the web strip that carries the shear. If the plate is already at its maximum depth, use a heavier beam.

常见问题

Why is the bolt group not designed for an eccentricity?

The bolts are in the face of the support, 与反应一致, so the module takes the design shear at the centroid of the bolt group and gives each of the eight bolts an equal share.

Why is the beam web checked over the end plate depth and not the full beam depth?

The shear gets out of the beam through the welds, and the welds only run the depth of the end plate. The web above and below the plate carries no shear into the connection, so Step 7 用途 325 毫米. 步骤 8 then checks the full beam section away from the connection.

Why does the end plate shear check have a factor of 2?

The end plate is welded to the beam web on its centreline, so the shear passes down two strips of plate, one on each side of the web, each the full depth and thickness of the plate. The module takes the 0.5 fy capacity of Clause 5.11.3 for each strip.

What makes an end plate flexible?

A thin plate, a wide gauge and a plate that is shallower than the beam and welded to the web only. Those let the plate bend between the bolt lines as the beam end rotates, so the connection carries little moment. A thick plate with a tight gauge, or one welded to the flanges, becomes a moment connection.

Why was the 150 kN design shear not increased to the Clause 9.1.4 最低?

条款 9.1.4 asks for a simple connection to be designed for at least the lesser of 0.15 times the beam’s design shear capacity and 40 千牛. 为了这 460 UB 82.1 那是 40 千牛, 和 150 kN entered is larger, so it is used as is.

此设计中是否检查了该列?

The column flange is checked as a ply in bearing in Step 4, and its width sets the edge distance and gauge limits in Step 1. For a column flange support the module does not run a separate shear check of the column.

Design a flexible end plate connection for free