To design a web side plate connection to AS 4100, you check every part of the load path from the beam web to the support: the bolts in shear and in bearing, the plate in shear, bending and block shear, the fillet welds to the support, 和梁腹板的剪力. The detailing limits on pitch, 螺栓的剪切强度, plate depth and clearance come first, because the capacity equations assume a connection that can be built and that rotates as a simple connection.
本页从头到尾介绍一个示例: 一个 460 UB 82.1 beam framing into the flange of a 310 加州大学 158 柱子, with a design shear of 150 千牛, eight M20 8.8/S bolts and a 10 mm Grade 250 盘子, designed to AS 4100:2020. 每个方程都用它的数字写出来, in the same order as the calculation report that the SkyCiv Connection Design 模块为其生成. The scope and conventions of the AS 4100 module are on the design of steel connections using AS 4100:2020 页.
What is a web side plate connection?
A web side plate connection is a flat plate fillet welded to the supporting member in the shop and bolted to the web of the supported beam on site. It carries the beam end shear and is detailed as a simple connection: the thin plate and the bolts let the beam end rotate, so the joint takes almost no end moment. It is also called a fin plate or a shear tab.
It is one of the most common shear connections in Australian building frames. The beam can be lowered into place between the columns without spreading them, and the only site work is bolting. The other shear connections in the AS 4100 module do the same job with a different load path: the flexible end plate is welded to the beam and bolted to the support, and the single and double angles are bolted on both sides. 这个你可以直接在 web side plate calculator.
In this example the plate is welded to the flange of the column and has two vertical lines of four bolts, so the bolt group is eight bolts on a 75 mm grid.

示例连接的标高. The beam stops 20 mm short of the column flange, 第一个螺栓列是 70 mm from the face of the support.

A-A部分. 该 10 mm plate sits on one side of the beam web, with an 8 mm E49XX fillet weld on both sides of the plate at the column.

SkyCiv 连接设计中的相同连接, with the plate selected on the Assembly tab.
Web side plate connection design: 步骤一目了然
- Check the connection detailing limits: 沥青, 边缘距离, plate depth and clearance.
- 检查最小角焊缝尺寸.
- Check the design capacity of the weld to the supporting member.
- Check the design capacity of the bolt group in shear, by the instantaneous centre of rotation.
- Check the bolt group in bearing on the plate and on the beam web.
- Check the web side plate in shear.
- Check the web side plate in bending.
- Check the web side plate in block shear.
- Check the supported member (梁网) 剪切力.
本示例的设计输入
The design code is AS 4100:2020, with section properties from the Australian section database. The yield strength of each part follows its grade and thickness: 的 16 mm beam flange gives 300 MPa for the beam, 的 25 mm column flange gives 280 MPa for the column, 和 10 mm Grade 250 plate gives 260 兆帕.
| 物品 | 象征 | 值 |
|---|---|---|
| Design shear (design action effect) | [mathin] V^{*} [mathin] | 150 千牛 |
| Beam | 460 UB 82.1, AS / NZS 3679.1 Gr.300 | |
| 波束深度 | [mathin] d_{bm} [mathin] | 460 毫米 |
| 梁腹板厚度 | [mathin] t_{wb} [mathin] | 9.9 毫米 |
| 梁翼缘宽度 / 厚度 | [mathin] b_{fb},\ t_{fb} [mathin] | 191 毫米 / 16 毫米 |
| 光束产率 / 抗拉强度 | [mathin] f_{yb},\ f_{ub} [mathin] | 300 兆帕 / 440 兆帕 |
| 柱 | 310 加州大学 158, AS / NZS 3679.1 Gr.300 | |
| 柱深 / 腹板厚度 | [mathin] d_{sup},\ t_{ws} [mathin] | 327 毫米 / 15.7 毫米 |
| 柱翼缘宽度 / 厚度 | [mathin] b_{fs},\ t_{fs} [mathin] | 311 毫米 / 25 毫米 |
| 柱产量 / 抗拉强度 | [mathin] f_{ys},\ f_{us} [mathin] | 280 兆帕 / 440 兆帕 |
| 弹性模量 | [mathin] E [mathin] | 200000 兆帕 |
| 物品 | 象征 | 值 |
|---|---|---|
| Web side plate | PL 10 X 200 X 320, AS / NZS 3678 Gr.250 | |
| 板宽 / 深度 / 厚度 | [mathin] b_{i},\ d_{i},\ t_{i} [mathin] | 200 毫米 / 320 毫米 / 10 毫米 |
| 板材产量 / 抗拉强度 | [mathin] f_{yp},\ f_{up} [mathin] | 260 兆帕 / 410 兆帕 |
| 螺栓 | M20 8.8/S, threads included in the shear plane | |
| 螺栓直径 / minimum tensile strength | [mathin] d_{f},\ f_{uf} [mathin] | 20 毫米 / 830 兆帕 |
| Holes in beam web and plate | [mathin] d_{h} [mathin] | 标称, 22 毫米 |
| Weld to column flange | 8 mm fillet both sides, E49XX, SP | |
| 焊缝尺寸 / weld metal strength | [mathin] t_{ww},\ f_{uw} [mathin] | 8 毫米 / 490 兆帕 |
| 几何 | 象征 | 值 |
|---|---|---|
| 螺栓排 / row pitch | [mathin] n_{p},\ s_{p} [mathin] | 4 / 75 毫米 |
| 螺栓柱 / column pitch | [mathin] n_{g},\ s_{g} [mathin] | 2 / 75 毫米 |
| Beam end clearance to column flange | [mathin] clr [mathin] | 20 毫米 |
| Support face to first bolt column | [mathin] l [mathin] | 70 毫米 |
| 梁腹板上水平边距 | [mathin] l_{eh\_w} [mathin] | 50 毫米 |
| 板材垂直边距 | [mathin] l_{ev\_wp} [mathin] | 47.5 毫米 |
| 板材水平边距 | [mathin] l_{eh\_wp} [mathin] | 55 毫米 |
| 螺栓组偏心率 | [mathin] e_{b} [mathin] | 107.5 毫米 |
| Weld group eccentricity | [mathin] e_{w} [mathin] | 0 毫米 |
The bolt group eccentricity is the distance from the face of the support to the centroid of the bolt group, 70 mm to the first bolt column plus half the 75 mm column pitch. The support is treated as flexible, so the weld group takes the shear with no eccentricity.
Design shear (作为 4100 条款 9.1.4)
作为 4100 条款 9.1.4 sets a minimum design action for a simple connection. 设计剪力不小于以下较小者 0.15 times the design shear capacity of the beam and 40 千牛. The beam capacity is the uncoped web shear capacity, which Step 9 uses again:
[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (460\ \text{mm}) \times (9.9\ \text{mm}) = 737.75\ \text{kN} [math]
[math] V^{*}_{min} = \min\left( 0.15\, \phi V_{vo},\ 40\ \text{kN} \right) = \min\left( 0.15 \times (737.75\ \text{kN}),\ 40\ \text{kN} \right) = 40\ \text{kN} [math]
[math] V^{*} = \max\left( V^{*},\ V^{*}_{min} \right) = \max\left( 150\ \text{kN},\ 40\ \text{kN} \right) = 150\ \text{kN} [math]
该 150 kN entered is well above the minimum, so it is the design action effect for every check below.
步骤 1: 连接详细限制 (作为 4100 条款 9.5)
Before any capacity check, the bolt layout has to be buildable and match the assumptions behind the capacity equations. Bolts too close together tear between the holes, edges too close tear out, and a plate that is too shallow or too deep changes how the connection rotates and whether it fits between the beam root radii.
The minimum pitch is [mathin] 2.5\, d_{f} = 2.5 \times 20\ \text{mm} = 50\ \text{mm} [mathin] (条款 9.5.1). The minimum edge distance for an M20 bolt is 35 毫米, [mathin] 1.75\, d_{f} [mathin] 从表 9.5.2. The maximum edge distance is 12 times the thinner ply, [mathin] 12 \times 9.9\ \text{mm} = 118.8\ \text{mm} [mathin], and the maximum column pitch is 15 times the thinner ply, [mathin] 15 \times 9.9\ \text{mm} = 148.5\ \text{mm} [mathin]. The plate must also be no deeper than the flat of the beam web, [mathin] 405.2\ \text{mm} [mathin], and the beam end must clear the column flange by at least 20 毫米.
| 详细限制 | 限制 (毫米) | 实际的 (毫米) | 直流电 | 结果 |
|---|---|---|---|---|
| Minimum bolt row pitch on plate | 50.000 | 75.000 | 0.667 | 通过 |
| Maximum bolt row pitch on plate | 139.600 | 75.000 | 0.537 | 通过 |
| Minimum bolt column pitch on plate | 50.000 | 75.000 | 0.667 | 通过 |
| Maximum bolt column pitch on plate | 148.500 | 75.000 | 0.505 | 通过 |
| Minimum vertical edge distance on plate | 35.000 | 47.500 | 0.737 | 通过 |
| Minimum horizontal edge distance on plate | 35.000 | 55.000 | 0.636 | 通过 |
| Minimum horizontal edge distance on beam web | 35.000 | 50.000 | 0.700 | 通过 |
| 最小板深 | 230.000 | 320.000 | 0.719 | 通过 |
| 最大板深 | 405.200 | 320.000 | 0.790 | 通过 |
| Minimum clearance | 20.000 | 20.000 | 1.000 | 通过 |
| Maximum edge distance | 118.800 | 55.000 | 0.463 | 通过 |
对于最小限制,该比率是实际值的限制, 对于最大值来说,它实际上超出了限制. The governing row is the clearance between the beam end and the column flange:
[math] DCR = \frac{20\ \text{mm}}{20\ \text{mm}} = 1.000 [math]
DCR = 1.000 ≤ 1.0, 行
正好有一个比例 1.000 这里是正常的. 该 20 mm gap was set at the minimum, so the check sits on its limit without being a strength problem.
步骤 2: 最小角焊缝尺寸 (作为 4100 桌子 9.6.3.2)
对于所连接的零件来说太小的角焊缝冷却得太快并且可能破裂, so AS 4100 桌子 9.6.3.2 sets a minimum size based on the thicker part, 这里的 25 mm column flange. That minimum is 6 毫米, and it may not exceed the thinner part, 的 10 mm plate.
The weld is also sized to develop the plate, so that if the plate yields in bending or shear the weld is not the weak link. The program takes this as three quarters of the plate thickness:
[math] t_{w,pl} = 0.75\, t_{i} = 0.75 \times (10\ \text{mm}) = 7.5\ \text{mm} [math]
[math] t_{w,req} = \max\left( t_{w,pl},\ t_{w,min} \right) = \max\left( 7.5\ \text{mm},\ 6\ \text{mm} \right) = 7.5\ \text{mm} [math]
[math] t_{ww} = 8\ \text{mm} \ge t_{w,req} = 7.5\ \text{mm} [math]
DCR = 7.5 毫米 / 8 毫米= 0.938 ≤ 1.0, 行
This ratio compares weld sizes, not a design action with a capacity. It is high because 8 mm is the next practical size above 7.5 毫米.
步骤 3: Design capacity of the weld to the supporting member (作为 4100 条款 9.6.3.10)
The two fillet welds join the plate to the column flange and carry the whole design shear. The weld is Structural Purpose (SP), so the capacity factor is 0.8 从表 3.4. The design capacity per unit length of an equal-leg fillet weld, with a throat of the leg size over the square root of 2:
[math] \phi v_{w} = \phi\, 0.6\, f_{uw}\, \frac{\sqrt{2}}{2}\, t_{ww}\, k_{r} [math]
[math] \phi v_{w} = (0.8) \times 0.6 \times (490\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (8\ \text{mm}) \times (1) = 1.3305\ \text{kN/mm} [math]
这里 [mathin] k_{r} = 1 [mathin] because the weld is not a long welded lap joint. The weld runs the full plate depth on both sides of the plate, [mathin] l_{w} = d_{i} = 320\ \text{mm} [mathin], and the support is flexible, so there is no eccentricity on the weld group:
[math] \phi V_{w} = 2\, l_{w}\, \phi v_{w} = 2 \times (320\ \text{mm}) \times (1.3305\ \text{kN/mm}) = 851.51\ \text{kN} [math]
[math] V^{*} = 150\ \text{kN} \le \phi V_{w} = 851.51\ \text{kN} [math]
DCR = 150 千牛 / 851.51 kN = 0.176 ≤ 1.0, 行
步骤 4: Design capacity of the bolt group in shear (作为 4100 Clauses 9.2.2.1, 9.3.1)
The design shear acts at the face of the support, 107.5 mm from the centroid of the bolts, so the bolt group carries a moment as well as the shear. The bolts nearest the corners take the most force. 条款 9.3.1 allows the bolt forces to be found by an analysis of the group, and the module uses the instantaneous centre of rotation (ICOR) 方法, which turns the eccentric group into a bolt group coefficient C.
Design shear capacity of one bolt
The threads are in the single shear plane, so the core area is used: [mathin] n_{n} = 1,\ A_{c} = 225\ \text{mm}^{2} [mathin] 和 [mathin] n_{x} = 0 [mathin]. The capacity factor for a bolt in shear is 0.8:
[math] \phi V_{f} = \phi\, 0.62\, f_{uf}\, k_{rd}\, k_{r}\, \left( n_{n} A_{c} + n_{x} A_{o} \right) [math]
[math] \phi V_{f} = (0.8) \times 0.62 \times (830\ \text{MPa}) \times (1) \times (1) \times \left( (1)(225\ \text{mm}^{2}) + (0)(314.16\ \text{mm}^{2}) \right) = 92.628\ \text{kN} [math]
The reduction factors are both 1: [mathin] k_{rd} [mathin] for ductility, 和 [mathin] k_{r} [mathin] because the joint is not a long bolted lap joint.
Locating the instantaneous centre
螺栓 1 is at the bottom left of the group. The instantaneous centre is found by iteration, as described on the 作为 4100 module page.
| 螺栓 | X (毫米) | 和 (毫米) |
|---|---|---|
| 1 | 0.00 | 0.00 |
| 2 | 0.00 | 75.00 |
| 3 | 0.00 | 150.00 |
| 4 | 0.00 | 225.00 |
| 5 | 75.00 | 0.00 |
| 6 | 75.00 | 75.00 |
| 7 | 75.00 | 150.00 |
| 8 | 75.00 | 225.00 |
The iteration converges with the instantaneous centre, measured from bolt 1, 在:
[math] x_{ic} = -30.727\ \text{mm}, \qquad y_{ic} = 112.5\ \text{mm} [math]
The bolt reactions at that point are:
| 螺栓 | [R (千牛) | 接收 (千牛) | 瑞 (千牛) | 锰 (kn-mm) |
|---|---|---|---|---|
| 1 | 88.65 | 85.52 | 23.36 | 10338.69 |
| 2 | 73.47 | 56.83 | 46.57 | 3562.07 |
| 3 | 73.47 | -56.83 | 46.57 | 3562.07 |
| 4 | 88.65 | -85.52 | 23.36 | 10338.69 |
| 5 | 90.91 | 66.25 | 62.26 | 14035.81 |
| 6 | 88.24 | 29.50 | 83.16 | 9898.73 |
| 7 | 88.24 | -29.50 | 83.16 | 9898.73 |
| 8 | 90.91 | -66.25 | 62.26 | 14035.81 |
Bolt group capacity
The vertical reactions add up to the capacity of the group. The horizontal reactions cancel, 所以 [mathin] \sum R_{x} [mathin] is zero to rounding:
[math] \phi V_{df} = \sqrt{ \left( \sum R_{x} \right)^{2} + \left( \sum R_{y} \right)^{2} } = \sqrt{ (0\ \text{kN})^{2} + (430.69\ \text{kN})^{2} } = 430.69\ \text{kN} [math]
[math] C = \frac{\phi V_{df}}{\phi V_{f}} = \frac{430.69\ \text{kN}}{92.628\ \text{kN}} = 4.6497 [math]
C= 4.65 for eight bolts means the 107.5 mm eccentricity costs the group a little over 40% of its concentric capacity. The same coefficient scales the bearing capacity in Step 5.
[math] V^{*} = 150\ \text{kN} \le \phi V_{df} = 430.69\ \text{kN} [math]
DCR = 150 千牛 / 430.69 kN = 0.348 ≤ 1.0, 行
步骤 5: Bolt group in bearing on the plate and the beam web (作为 4100 条款 9.2.2.4)
Each bolt bears on the side of its hole in the plate and in the beam web. A ply can fail by crushing at the hole, 上限为 [mathin] 3.2\, d_{f}\, t_{p}\, f_{up} [mathin], or by tearing out to an edge or to the next hole, which depends on [mathin] a_{e} [mathin]. Under ICOR the bolt forces act in different directions, so the least distance in any direction governs each ply.
Bearing on the web side plate
[mathin] a_{e} [mathin] is the distance from the edge of the hole to the edge of the ply, or to the next hole, 加上螺栓直径的一半. 和 [mathin] d_{h} = 22\ \text{mm} [mathin]:
[math] a_{e1} = l_{ev\_wp} – 0.5\, d_{h} + 0.5\, d_{f} = (47.5\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 46.5\ \text{mm} [math]
[math] a_{e2} = s_{p} – d_{h} + 0.5\, d_{f} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]
[math] a_{e3} = l_{eh\_wp} – 0.5\, d_{h} + 0.5\, d_{f} = (55\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 54\ \text{mm} [math]
[math] a_{e4} = s_{g} – d_{h} + 0.5\, d_{f} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]
[math] a_{e} = \min\left( 46.5,\ 63,\ 54,\ 63 \right)\ \text{mm} = 46.5\ \text{mm} [math]
The capacity factor for a ply in bearing is 0.9:
[math] \phi V_{b} = \phi \min\left( 3.2\, d_{f}\, t_{i}\, f_{up},\ a_{e}\, t_{i}\, f_{up} \right) [math]
[math] \phi V_{b,pl} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (10\ \text{mm}) \times (410\ \text{MPa}),\ (46.5\ \text{mm}) \times (10\ \text{mm}) \times (410\ \text{MPa}) \right) = 171.59\ \text{kN} [math]
The edge distance term governs, so the vertical edge distance at the top and bottom of the plate controls the plate’s bearing capacity.
梁腹板上的轴承
The beam is uncoped, so there is no vertical edge on the beam web near the bolts. The distances are to the next hole and to the end of the beam:
[math] a_{e5} = s_{p} – d_{h} + 0.5\, d_{f} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]
[math] a_{e6} = l_{eh\_w} – 0.5\, d_{h} + 0.5\, d_{f} = (50\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 49\ \text{mm} [math]
[math] a_{e7} = s_{g} – d_{h} + 0.5\, d_{f} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]
[math] a_{e} = \min\left( 63,\ 49,\ 63 \right)\ \text{mm} = 49\ \text{mm} [math]
[math] \phi V_{b,beam} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (9.9\ \text{mm}) \times (440\ \text{MPa}),\ (49\ \text{mm}) \times (9.9\ \text{mm}) \times (440\ \text{MPa}) \right) = 192.1\ \text{kN} [math]
Bolt group bearing capacity
The weaker ply per bolt, scaled by the bolt group coefficient from Step 4:
[math] \phi V_{b} = \min\left( \phi V_{b,pl},\ \phi V_{b,beam} \right) C = \min\left( 171.59\ \text{kN},\ 192.1\ \text{kN} \right) \times (4.6497) = 797.82\ \text{kN} [math]
[math] V^{*} = 150\ \text{kN} \le \phi V_{b} = 797.82\ \text{kN} [math]
DCR = 150 千牛 / 797.82 kN = 0.188 ≤ 1.0, 行
The plate governs over the beam web even though the web is slightly thinner, because its 410 MPa tensile strength is lower than the beam’s 440 MPa and its edge distance term is smaller.
步骤 6: Web side plate in shear (作为 4100 条款 5.11.3)
The whole design shear passes down through the plate as vertical shear. A rectangular plate does not carry shear uniformly: the stress peaks at mid-depth. 条款 5.11.3 allows for that non-uniform distribution, which for a rectangular section brings the capacity down to 0.5 fy on the gross area, instead of the 0.6 fy used for a beam web:
[math] \phi V_{v} = \phi\, 0.5\, f_{yp}\, d_{i}\, t_{i} [math]
[math] \phi V_{v} = (0.9) \times 0.5 \times (260\ \text{MPa}) \times (320\ \text{mm}) \times (10\ \text{mm}) = 374.4\ \text{kN} [math]
[math] V^{*} = 150\ \text{kN} \le \phi V_{v} = 374.4\ \text{kN} [math]
DCR = 150 千牛 / 374.4 kN = 0.401 ≤ 1.0, 行
This is the highest load ratio in the connection, and it is set by the plate’s grade and size, not the bolts. 一个薄薄的, lower-strength plate like this one yields before the bolts or welds, which keeps the connection flexible.
步骤 7: Web side plate in bending (作为 4100 条款 5.2.1)
The plate is a short cantilever from the face of the column to the bolt group, so the design shear causes bending in the plate at the support. The design section moment capacity of the rectangular plate, using its plastic section modulus:
[math] \phi M_{s} = \phi\, \frac{f_{yp}\, t_{i}\, d_{i}^{2}}{4} [math]
[math] \phi M_{s} = (0.9) \times \frac{(260\ \text{MPa}) \times (10\ \text{mm}) \times (320\ \text{mm})^{2}}{4} = 59.904\ \text{kNm} [math]
Expressed as the shear it can carry at the bolt group eccentricity:
[math] \phi V_{n} = \frac{\phi M_{s}}{e_{b}} = \frac{59.904\ \text{kNm}}{107.5\ \text{mm}} = 557.25\ \text{kN} [math]
[math] V^{*} = 150\ \text{kN} \le \phi V_{n} = 557.25\ \text{kN} [math]
DCR = 150 千牛 / 557.25 kN = 0.269 ≤ 1.0, 行
步骤 8: Web side plate in block shear (作为 4100 条款 9.1.9)
A block of the plate can tear out around the bolts: shear down the outer bolt column to the bottom edge, plus tension across the bolt columns to the free edge of the plate. With two bolt columns this is an L-shaped block.
受拉净面积, along the bottom bolt row:
[math] A_{nt} = \left[ l_{eh\_wp} + (n_{g} – 1)\, s_{g} – (n_{g} – 0.5)\, d_{h} \right] t_{i} [math]
[math] A_{nt} = \left[ (55\ \text{mm}) + (2 – 1)(75\ \text{mm}) – (2 – 0.5)(22\ \text{mm}) \right] \times (10\ \text{mm}) = 970\ \text{mm}^{2} [math]
剪切总面积和净面积, along the bolt column:
[math] A_{gv} = \left[ l_{ev\_wp} + (n_{p} – 1)\, s_{p} \right] t_{i} = \left[ (47.5\ \text{mm}) + (4 – 1)(75\ \text{mm}) \right] \times (10\ \text{mm}) = 2725\ \text{mm}^{2} [math]
[math] A_{nv} = \left[ l_{ev\_wp} + (n_{p} – 1)\, s_{p} – (n_{p} – 0.5)\, d_{h} \right] t_{i} = \left[ (47.5\ \text{mm}) + (3)(75\ \text{mm}) – (3.5)(22\ \text{mm}) \right] \times (10\ \text{mm}) = 1955\ \text{mm}^{2} [math]
The tension stress is uniform, 所以 [mathin] k_{bs} = 1 [mathin], and the capacity factor for block shear is 0.75:
[math] \phi R_{bs} = \phi \min\left( 0.6\, f_{up}\, A_{nv} + k_{bs}\, f_{up}\, A_{nt},\ 0.6\, f_{yp}\, A_{gv} + k_{bs}\, f_{up}\, A_{nt} \right) [math]
[math] \phi R_{bs} = (0.75) \times \min\left( 0.6 \times (410)(1955) + (1)(410)(970),\ 0.6 \times (260)(2725) + (1)(410)(970) \right) \times 10^{-3} = 617.1\ \text{kN} [math]
[math] V^{*} = 150\ \text{kN} \le \phi R_{bs} = 617.1\ \text{kN} [math]
DCR = 150 千牛 / 617.1 kN = 0.243 ≤ 1.0, 行
The second term, shear yielding on the gross area, is the smaller one, so the block would yield along the bolt column before it ruptured.
步骤 9: Supported member in shear (作为 4100 条款 5.11.2)
At the connection the beam web carries the full end shear. The beam is uncoped, so the whole web depth is available. 第一, the web has to be stocky enough to reach shear yield without buckling:
[math] \frac{d_{p}}{t_{w}} = 43.232 \le \frac{82}{\sqrt{f_{y} / 250}} = 74.855 [math]
The web is not slender, so the design shear capacity is the yield capacity of the web:
[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (460\ \text{mm}) \times (9.9\ \text{mm}) = 737.75\ \text{kN} [math]
[math] V^{*} = 150\ \text{kN} \le \phi V_{vo} = 737.75\ \text{kN} [math]
DCR = 150 千牛 / 737.75 kN = 0.203 ≤ 1.0, 行
For a column flange support the module does not run a local check of the supporting member. The column flange enters the design through the minimum weld size in Step 2.
检查摘要
| 设计检查 | Design action effect | Design capacity | 直流电 | 结果 |
|---|---|---|---|---|
| 连接详细限制 | 20 毫米 | 20 毫米 | 1.000 | 通过 |
| Minimum weld size | 7.5 毫米 | 8 毫米 | 0.938 | 通过 |
| Weld to supporting member | 150 千牛 | 851.515 千牛 | 0.176 | 通过 |
| 剪切螺栓组 | 150 千牛 | 430.692 千牛 | 0.348 | 通过 |
| Bolt group in bearing on plate and beam web | 150 千牛 | 797.819 千牛 | 0.188 | 通过 |
| Web side plate in shear | 150 千牛 | 374.4 千牛 | 0.401 | 通过 |
| Web side plate in bending | 150 千牛 | 557.247 千牛 | 0.269 | 通过 |
| Web side plate in block shear | 150 千牛 | 617.1 千牛 | 0.243 | 通过 |
| Supported member in shear | 150 千牛 | 737.748 千牛 | 0.203 | 通过 |
连接通过了每项检查. 两个比例接近 1.0, and neither one compares a design action with a capacity. The detailing check is 1.000 because the beam end clearance was set at the 20 mm minimum, and the minimum weld size check is 0.938 因为 8 mm weld is the next size above the 7.5 mm needed to develop the plate. Of the checks that compare the design shear with a design capacity, the web side plate in shear governs at 0.401, followed by the bolt group in shear at 0.348.
Auto Design is available for the web side plate in the AS 4100 模块. 它改变了螺栓, 板材和焊接直到每项检查都通过, and keeps your members and design actions as entered. 见 汽车设计 page for the AS 4100 preferences it works to.
如果检查失败要更改什么
- 构造限制: adjust the pitch, edge distances or plate depth to the limits in Step 1. A plate deeper than the flat of the beam web will not fit between the root radii, so add a bolt column rather than a row if the depth is maxed out.
- Minimum weld size: increase the fillet weld size to at least 0.75 times the plate thickness and the Table 9.6.3.2 最低.
- 焊接能力: 增加焊缝尺寸, use a stronger electrode, or make the plate deeper to lengthen the welds.
- 剪切螺栓组: 添加螺栓行, 这提高了C, use a larger bolt or a higher bolt grade, or move the bolts closer to the support to reduce the eccentricity.
- Bolt bearing: increase the vertical edge distance on the plate, 使用较厚的板, or add bolts. If the beam web governs, add bolts or use a larger bolt.
- Plate shear, bending or block shear: make the plate deeper, 或更厚. A thicker plate also raises the minimum weld size and makes the connection stiffer, so prefer a deeper plate where the beam web allows.
- 受剪梁腹板: 这仅取决于光束, 所以使用较重的部分.
常见问题
为什么螺栓组设计用于 107.5 mm eccentricity?
The module takes the design shear at the face of the support and designs the bolt group for the full distance from there to the centroid of the bolts: 70 mm to the first bolt column plus half the 75 mm column pitch. The welds are then designed for the shear alone, because the support is treated as flexible. This is the conservative side for the bolts, which are the more brittle part of the load path.
Why does the plate shear check use 0.5 fy and not 0.6 风云?
作为 4100 条款 5.11.3 covers members where the shear stress is not uniform across the section. In a solid rectangle the stress peaks at mid-depth at 1.5 times the average, so the capacity of the plate works out to 0.5 fy on the gross area. A beam web, where the shear stress is close to uniform, 用途 0.6 fy under Clause 5.11.2.
Why was the 150 kN design shear not increased to the Clause 9.1.4 最低?
条款 9.1.4 asks for a simple connection to be designed for at least the lesser of 0.15 times the beam’s design shear capacity and 40 千牛. 为了这 460 UB 82.1 that is the lesser of 0.15 X 737.75 千牛和 40 千牛, 所以最小值是 40 千牛. 该 150 kN entered is larger, so it is used as is. For a lightly loaded beam the minimum can govern, and the report shows it in the same place.
Why is the weld 8 mm when Table 9.6.3.2 only asks for 6 毫米?
桌子 9.6.3.2 sets the smallest weld that can be laid safely on a 25 mm column flange. The connection also needs the weld to be stronger than the plate, so that the plate yields first and the connection stays ductile. The program sizes this at 0.75 板厚的倍数, 7.5 mm for a 10 mm plate, 和 8 mm is the next practical size.
Do I need slip-critical bolts for a web side plate?
没有. A web side plate is a bearing-type connection, and 8.8/S bolts snug tightened are the usual choice, as in this example. If you choose 8.8/TF or 10.9/TF bolts, or use oversize or slotted holes that make the group friction type, the report adds the serviceability check of Clause 9.2.3.1.
此设计中是否检查了该列?
For a column flange support, the column enters through the weld: 的 25 mm flange sets the Table 9.6.3.2 最小焊接尺寸. The module runs a local capacity check of the supporting member only for column web and beam web supports, where a thin web takes the plate’s weld directly.
Design a web side plate connection for free
此页上的每个数字都来自一个解决方案. Pick AS 4100:2020 and the web side plate, 输入你的光束, 支持, bolts and design shear, 并在浏览器中查看每项检查. 没有什么可安装的.
SkyCiv Connection Design 模块是本示例背后的连接设计软件. 它为您提供完整的计算报告,其中包含每个方程和您的数字, 就像上面的步骤一样, plus every design capacity and DCR, 对于作为 4100:2020 剪力连接, moment connections and splices. 该 螺栓计算器 和 焊接计算器 自行覆盖螺栓组和焊接检查.
参考资料
- 作为 4100:2020, 钢结构: Clauses 5.2.1, 5.11.2, 5.11.3, 9.1.4, 9.1.9, 9.2.2.1, 9.2.2.4, 9.3.1, 9.5 (桌子 9.5.2), 9.6.3.10; 桌子 3.4 和 9.6.3.2.
- Design of steel connections using AS 4100:2020
- 汽车设计 SkyCiv 连接设计
哈罗德穆纳勒姆
产品经理, 连接设计
10+ 从事钢结构连接设计多年