This page walks through the isolated footing design checks that SkyCiv Foundation performs to ACI 318-19: rolamento do solo, cisalhamento unidirecional, punching shear and flexure, with the equations used, plus the stability checks (forças de elevação, overturning and sliding). Flexure is described with the default Strip average method, quanto pelo Peak wood-armer method is summarized for comparison.
A fundação é um sistema de construção essencial que transfere as forças da coluna e da parede para o solo de suporte. O engenheiro pode optar por um sistema de fundação raso ou profundo com base nas características do solo e nas cargas do edifício.. SkyCiv Foundation designs isolated footings (sapatas isoladas) to the American code ACI 318-19. To use it, selecione American Concrete Institute as the Design Code and ACI 318 (2019) as the Version when you start a new file, then pick Sapata isolada.

The example shown on this page is the default pad footing (1500 × 1500 × 500 mm footing, 300 × 300 mm column, #5 bars at 150 mm each way) with a dead load of 400 kN and a live load of 250 kN on the column.
Design Settings for ACI 318-19
The methods used for the checks are set in Edit Design Settings (Details tab). For ACI 318-19, a Moment Demand Calculation offers the Strip average method (padrão) quanto pelo Peak wood-armer method. The settings also hold the Perform One-Way Shear Check toggle and the Punching Shear Edge Factor (0.5 por padrão).

Um guia passo a passo para projetar uma sapata isolada
Requisitos de dimensões
Para determinar as dimensões de uma sapata isolada, serviço ou cargas não fatoradas, como Morto (D), Viver (L), Vento (C), Sísmica (E), etc. are combined using the load combinations of ACI 318-19 (Tabela 5.3.1). Whichever load combination governs is considered the design load, e é comparado com a pressão do solo permitida, conforme mostrado na Equação 1, as required by Seção 13.3.1.1 de ACI 318-19.
[math] q_{a} = \frac{P_{n}}{A} \quad \text{(Eq. 1)} [math]
quma = Pressão admissível do solo
Pn = Carga de projeto não fatorada
A = área da fundação
As dimensões da sapata podem ser inicialmente estimadas resolvendo a área da fundação (A) usando a Equação 1.
[math] A = \frac{P_{n}}{q_{a}} \quad \text{(Eq. 1a)} [math]
In SkyCiv Foundation, the footing dimensions are inputs (Geometry tab). The software checks them with the soil pressures from the finite element analysis, as described in Pressão do solo.
Cisalhamento unidirecional
O estado limite de cisalhamento unidirecional, também conhecido como cisalhamento de viga, recognizes that the footing may fail in shear similar to a wide beam along a critical section located at a distance “d” da face da coluna (Figura 1). SkyCiv Foundation checks it in both directions (along x and along z). It can be turned off with Perform One-Way Shear Check in the design settings (ativado por padrão).

Figura 1. One-way shear diagram (Resultados, Diagrams button)
A One-way Shear Demand ou \( V_{u} \) is taken from the strip shear diagram of the footing: the shear forces of the finite element analysis are summed across the full width of the footing, along a strip through the column, and read at the two critical sections. The larger absolute value of the ultimate load combinations is used, em cada direção.
A Capacidade de cisalhamento unilateral ou \( \phi V_{c} \) is calculated with Equation 2 (Tabela 22.5.5.1(c), for members without shear reinforcement), with the full width of the footing perpendicular to the direction checked. The size effect factor \( \lambda_{s} \) is neglected for footings, as permitted by Seção 13.2.6.2.
[math] \phi V_{c} = \phi_{\text{shear}} \times 8 \lambda \left( \rho_{w} \right)^{1/3} \sqrt{f’_{c}} \times b_{w} \times d \quad \text{(Eq. 2, Table 22.5.5.1(c), Imperial)} [math]
ou
[math] \phi V_{c} = \phi_{\text{shear}} \times 0.66 \lambda \left( \rho_{w} \right)^{1/3} \sqrt{f’_{c}} \times b_{w} \times d \quad \text{(Eq. 2, Table 22.5.5.1(c), Metric)} [math]
[math] \rho_{w} = \frac{n \times A_{b}}{b_{w} \times d} [math]
ϕo cisalhamento = Shear strength reduction factor, 0.75 (Tabela 21.2.1)
λ = Modification factor for lightweight concrete
ρC = Ratio of the bottom bars in the direction checked
n, Ab = Number and area of these bars
f’c = Resistência específica do concreto, (psi, MPa)
bC = Width of the footing perpendicular to the direction checked, (no, milímetros)
d = Effective depth of the bottom bars in the direction checked, (no, milímetros)
A demanda de cisalhamento e a capacidade de cisalhamento devem atender à seguinte equação para atender aos requisitos de projeto da ACI 318-19:
[math] V_{u} \leq \phi V_{c} \quad \text{(Eq. 3, Section 7.5.1.1(b))} [math]
SkyCiv Foundation, em conformidade com a equação 3, calcula a taxa de utilidade de cisalhamento unidirecional (Equação 4) considerando a demanda de cisalhamento sobre a capacidade de cisalhamento. The larger ratio of the two directions is listed as Tesoura unidirecional in the Design Checks Summary.
[math] \text{Utility Ratio} = \frac{\text{Shear Demand}}{\text{Shear Capacity}} \quad \text{(Eq. 4)} [math]
Cisalhamento bidirecional (Puncionadeira)
The two-way shear limit state, também conhecido como punçoamento, has its critical section at a distance “d/2” from the faces of the column, around the perimeter of the column (Figura 2). Its length is the critical perimeter \( b_{o} \).

Figura 2. Critical perimeter of two-way shear (Resultados, Diagrams button)
When a column face is closer to a footing edge than the Punching Shear Edge Factor vezes d (design settings, 0.5 por padrão), the perimeter on that side extends to the footing edge and is not counted in \( b_{o} \). The column is then classified as an interior, edge or corner column, which sets \( \alpha_{s} \) = 40, 30 ou 20 (Seção 22.6.5.3). If the column is close to two opposite edges, the punching shear check is skipped, as one-way shear governs.
A Two-way Shear Demand is calculated at the critical perimeter with the mesh-based method, from the finite element analysis of the footing. The upward force from the soil pressure inside the critical perimeter, \( F_{q} \), is the sum of the forces of the mesh elements in that area, and it is subtracted from the factored column load. The maximum shear stress \( v_{u} \) on the critical perimeter also includes the unbalanced moments transferred by eccentric shear (ACI 421.1R-20):
[math] v_{u} = \frac{P_{u} – F_{q}}{b_{o} \times d} + \frac{\gamma_{v,x} \times M_{u,x} \times c_{x}}{J_{c,x}} – \frac{\gamma_{v,z} \times M_{u,z} \times c_{z}}{J_{c,z}} \quad \text{(Eq. 5)} [math]
Pvocê = Factored column load
cv = Fraction of the unbalanced moment transferred by eccentric shear
Mvocê = Unbalanced moment: column moment, plus column shear times the column height and footing thickness, minus the column load times the offset of the centroid of the critical section (edge and corner columns)
c, Jc = Distance to the point considered and polar moment of inertia of the critical section
D = profundidade efetiva, the average of the effective depths of the bottom bars in both directions
A Capacidade de cisalhamento is the punching shear stress \( \phi v_{c} \), governed by the smallest value of Equations 6, 7 e 8 por Seção 22.6.5.2. Unlike ACI 318-14, a 2019 edition includes the size effect factor \( \lambda_{s} \) (Seção 22.5.5.1.3), which reduces the capacity of footings with an effective depth over 10 no (250 milímetros).
[math] \lambda_{s} = \min \left( 1, \sqrt{\frac{2}{1 + d/10}} \right) \quad \text{(Imperial)} \qquad \lambda_{s} = \min \left( 1, \sqrt{\frac{2}{1 + 0.004\,d}} \right) \quad \text{(Metric)} [math]
[math] v_{c} = 4 \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 6, Section 22.6.5.2(a), Imperial)} [math]
[math] v_{c} = \left( 2 + \frac{4}{\beta} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 7, Section 22.6.5.2(b), Imperial)} [math]
[math] v_{c} = \left( 2 + \frac{\alpha_{s} \times d}{b_{o}} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 8, Section 22.6.5.2(c), Imperial)} [math]
ou
[math] v_{c} = 0.33 \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 6, Section 22.6.5.2(a), Metric)} [math]
[math] v_{c} = \left( 0.17 + \frac{0.33}{\beta} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 7, Section 22.6.5.2(b), Metric)} [math]
[math] v_{c} = \left( 0.17 + \frac{0.083 \times \alpha_{s} \times d}{b_{o}} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 8, Section 22.6.5.2(c), Metric)} [math]
[math] \phi v_{c} = \phi_{\text{shear}} \times \min \left( v_{c,a}, v_{c,b}, v_{c,c} \right) [math]
Observação: β é a razão entre o lado longo e o lado curto da coluna (1.0 for a round column, which is treated as an equivalent square), e \( \alpha_{s} \) is given by Section 22.6.5.3. ϕo cisalhamento = 0.75 (Tabela 21.2.1).
λs = Size effect modification factor
λ = Fator de modificação para refletir as propriedades mecânicas reduzidas do concreto leve em relação ao concreto normal com a mesma resistência à compressão
f’c = Resistência especificada do concreto à compressão (psi, MPa)
D = profundidade efetiva, the average of the effective depths of the bottom bars in both directions, (no, milímetros)
bo = Critical perimeter (no, milímetros)
A demanda de cisalhamento e a capacidade de cisalhamento devem atender à seguinte equação para atender aos requisitos de projeto da ACI 318-19:
[math] v_{u} \leq \phi v_{c} \quad \text{(Eq. 9, Section 7.5.1.1(b))} [math]
SkyCiv Foundation, em conformidade com a equação 9, calcula a taxa de utilidade de cisalhamento bidirecional (Equação 10) considerando a demanda de cisalhamento sobre a capacidade de cisalhamento, both as stresses. The result is listed as Puncionadeira in the Design Checks Summary.
[math] \text{Utility Ratio} = \frac{\text{Shear Demand}}{\text{Shear Capacity}} \quad \text{(Eq. 10)} [math]
Flexão
Moment Demand with the Strip Average Method
A Demanda Flexural ou \( M_{u} \) comes from the finite element analysis of the footing. Com o Strip average method (o padrão Moment Demand Calculation), the footing is treated like a wide beam in each direction: the Wood-Armer moments of the plate elements are summed across the full width of the footing, along a strip through the column, which gives the total moment carried by the whole width at each section (Figura 3). This is done for the top and bottom layers, along x and along z, under the ultimate load combinations.
- Bottom layer: \( M_{u} \) is the strip moment at the column faces, the larger of the two faces.
- Top layer: \( M_{u} \) is the largest hogging (negativo) strip moment along the strip.

Figura 3. Strip average moment diagram, bottom layer along X (Resultados, Diagrams button)
The detailed report shows the same diagram for each layer and direction, with a table of the maximum moment, its coordinates and the governing load combination, followed by the utility ratio (Figura 4).

Figura 4. Moment demand and utility ratio in the design report (Ver relatório detalhado)
Peak Wood-Armer Method
Com o Peak wood-armer method, \( M_{u} \) is instead the maximum Wood-Armer moment per unit width found anywhere over the footing, for the top and bottom layers in both directions, and the capacity is calculated per unit width (12 in or 1000 milímetros). Because it uses the peak moment, usually at the column, rather than the moment spread over the full width, it gives a more conservative design. It is described in the Passo a passo do projeto de sapata isolada com ACI 318-14, where it is the only method available.
Capacidade Flexural
With the strip average method, a Capacidade Flexural ou \( \phi M_{n} \) is calculated for the full width of the footing, with all the bars of the layer across that width, usando a Equação 11.
[math] \phi M_{n} = \phi_{\text{flexure}} \times A_{s} \times f_{y} \times \left( d – \frac{a}{2} \right) \quad \text{(Eq. 11)} [math]
[math] a = \frac{A_{s} \times f_{y}}{0.85 \times f’_{c} \times b} [math]
ϕflexura = flexural strength reduction factor (Tabela 21.2.2)
As = area of the bars of the layer across the width of the footing (no2, milímetros2)
fY = reinforcement strength, (psi, MPa)
d = distância da fibra de compressão extrema ao centroide do reforço de tensão longitudinal (no, milímetros)
a = profundidade do bloco de tensão retangular equivalente (no, milímetros)
b = width of the footing perpendicular to the bars (no, milímetros)
The strength reduction factor depends on the net tensile strain \( \varepsilon_{t} \), found from the neutral axis depth \( c = a/\beta_{1} \) (b1 da mesa 22.2.2.4.3) and a concrete strain of 0.003. ACI 318-19 compares it with the yield strain of the reinforcement \( \varepsilon_{ty} = f_{y}/E_{s} \):
[math] \phi_{\text{flexure}} = 0.65 + 0.25 \times \frac{\varepsilon_{t} – \varepsilon_{ty}}{0.003} \quad \text{(Table 21.2.2)} [math]
with ϕ = 0.90 quando \( \varepsilon_{t} \geq \varepsilon_{ty} + 0.003 \) (tension-controlled) and ϕ = 0.65 quando \( \varepsilon_{t} \leq \varepsilon_{ty} \) (compression-controlled). The report shows a warning when the section is not tension-controlled. When top bars are provided and the tension steel ratio exceeds the balanced ratio, the section is checked as doubly reinforced.
The provided reinforcement is also compared to the minimum area of 0.0018 Ag (Seção 8.6.1.1), in each direction and for each layer. Without top bars, the top face is checked as plain concrete (Seção 14.5.2.1):
[math] \phi M_{n} = \phi \times 5 \lambda \sqrt{f’_{c}} \times S \quad \text{(Imperial)} \qquad \phi M_{n} = \phi \times 0.42 \lambda \sqrt{f’_{c}} \times S \quad \text{(Metric)} [math]
ϕ = 0.60 for plain concrete
S = section modulus of the full width of the footing (b × h2/6)
A Demanda de Momento e a Capacidade de Momento devem atender à seguinte equação para atender aos requisitos de projeto da ACI 318-19:
[math] M_{u} \leq \phi M_{n} \quad \text{(Eq. 12, Section 7.5.1.1(a))} [math]
SkyCiv Foundation, em conformidade com a equação 12, calcula a taxa de utilidade flexural (Equação 13) tomando Flexural Demand em vez de Flexural Capacity. The Flexure ratio in the Design Checks Summary is the largest of the top, bottom and minimum reinforcement ratios. In the example, the bottom layer along X has a ratio of 121.5/203.01 = 0.598, and the Flexure ratio of 0.671 comes from the minimum reinforcement check.
[math] \text{Utility Ratio} = \frac{\text{Flexure Demand}}{\text{Flexure Capacity}} \quad \text{(Eq. 13)} [math]
Verificações adicionais
Outras verificações não mencionadas no código, incluindo verificações de pressão do solo, forças de elevação, e outras verificações de estabilidade também são verificadas. The Design Checks Summary also lists Transferência de Carga (bearing at the column base), Processo de fluxo de trabalho de design de sapata espalhada e Detalhamento. The development length checks are explained in the ACI 318 (2019) Guia de verificação de comprimento de desenvolvimento.
Pressão do solo
A determinação da pressão de base ou da interação entre o solo e a sapata depende principalmente das dimensões da sapata e da excentricidade resultante das cargas aplicadas. Dependendo do posicionamento desta excentricidade resultante, a pressão na base pode induzir compressão total ou parcial na sapata. Esta avaliação permite-nos confirmar se o solo subjacente pode suportar a totalidade das cargas transmitidas pela sapata. SkyCiv Foundation takes the soil pressures from the finite element analysis of the footing.

Para obter um guia detalhado para calcular manualmente a pressão do solo, por favor consulte este link: Distribuição de pressão sob uma sapata de concreto retangular
A taxa de utilidade é avaliada comparando a pressão máxima do solo (estado de utilização) com o Capacidade Bruta Permissível de Suporte do Solo entered in the Soil tab. It is listed as Processo de fluxo de trabalho de design de sapata espalhada in the Design Checks Summary.
[math] \text{Utility Ratio} = \frac{\text{Max. Soil Pressure}}{\text{Gross Allowable Soil Bearing Capacity}} \quad \text{(Eq. 14)} [math]
Arrancamento
Verifica a carga axial governante que atua na sapata, considering axial loads only. Soma todas as cargas verticais, incluindo a carga do usuário e os pesos próprios da coluna, laje de pé, solo, e força de empuxo. Se a coluna sofrer uma força ascendente, os pesos próprios especificados devem contrabalançar a força ascendente; caso contrário, o projeto corre o risco de falhar devido à instabilidade. When no service load combination produces uplift, the check is not needed.
Tombamento
Overturning of the footing is checked by summing up all moments about the toe and the heel of the footing in each direction, including all the forces acting on it. All service load combinations are considered to find the governing overturning moment. The factor of safety (stabilising moment over overturning moment) is compared with the Tombamento factor of safety in the Fatores de projeto aba (2.0 por padrão). If the applied loads produce no overturning moment, the check is not needed.
Deslizamento
To check for sliding in each direction, the sum of the horizontal resisting forces is divided by the horizontal force applied to the footing, taken from the governing service load combination.
- Resisting forces:
- Friction between the footing base and the soil (coefficient of friction times the axial force on the base; none under net uplift)
- Pressão passiva do solo
- Cohesion of the soil
- Força de deslizamento:
- The horizontal (o cisalhamento) load applied to the column
The resulting factor of safety is compared with the Deslizamento factor of safety in the Fatores de projeto aba (1.5 por padrão). Se nenhuma força horizontal estiver atuando na base, verificar se há deslizamento não é necessário.
Módulo SkyCiv Foundation Design
O Foundation Design Module do SkyCiv é integrado à análise de elementos finitos (FEIO), delivering more accurate soil pressure analysis and Wood-Armer moments for the flexural design checks.
Shear and moment diagrams are generated directly from the FEA results using the strip average method, fornecendo uma imagem mais clara das forças internas em toda a base. Open them with the Diagrams button of the Results tab, and pick the Caso, a Diagram (Cisalhamento unidirecional, Punching Shear or Moment), a Combinação de carga, a Camada quanto pelo Direção.
O módulo suporta configurações avançadas de base, incluindo deslocamentos de pilares em qualquer direção para sapatas isoladas e combinadas. Cargas e momentos também podem ser aplicados em qualquer direção, permitindo a modelagem precisa das condições de fundação do mundo real.
Não é um usuário SkyCiv? Inscreva-se para um Gratuita 14 Dia de teste para começar!
Desenvolvedor de produto
bacharelado (Civil), Mestrado (Civil)
Referências
- Requisitos de Código para Concreto Estrutural (ACI 318-19) e Comentário (ACI 318R-19). American Concrete Institute, 2019.
- ACI Committee 421. Guide to Shear Reinforcement for Slabs (ACI 421.1R-20). American Concrete Institute, 2020.