SkyCivドキュメント

SkyCivソフトウェアのガイド — チュートリアル, ハウツーガイドと技術記事

ASCE 7-22 地震荷重の計算

SkyCiv Load Generator calculates ASCE 7-22 seismic loads for buildings with the Equivalent Lateral Force (ELF) 手順. It looks up the seismic design parameters for your site, then gives you the seismic base shear, the vertical distribution of forces per floor, the diaphragm forces and the design response spectrum. This page explains each input in the seismic workflow and how the calculation uses it.

Free accounts can try the workflow with limited solves. With a Professional Account or the スタンドアロンの負荷ジェネレータモジュール, you get unlimited use of every feature, including the detailed seismic calculation report.

Workflow Overview

The workflow follows the same top-to-bottom order as the rest of the SkyCiv Load Generator:

  1. 選択する ASCE 7-22 as the design code and the unit system (ヤード・ポンド法またはメートル法).
  2. に サイトデータ, enter the location, the Risk Category and the Site Class.
  3. に 構造データ, を選択 建物 structure and enter its dimensions.
  4. 開いた 地震荷重 and define the seismic parameters.
  5. クリック 荷重の計算 and review the results.

地形係数を計算することにより、構造物の風荷重に対する地形の影響について説明します。 7-22, the seismic calculation is available for the 建物 構造. For the ASCE 7-16 バージョン, which also covers solar panels and rooftop equipment, 見る ASCE 7-16 地震荷重の計算.

サイトデータ: Seismic Design Parameters

プロジェクトのアドレスを入力してください (or drop a pin on the map) そして、 リスクカテゴリー. 下 For Seismic Load, を選択 サイトクラス from the ASCE 7-22 リスト:

  • Default Site Conditions
  • あ – Hard rock
  • B – Medium hard rock
  • 紀元前 – Soft rock
  • C – Very dense sand or hard clay
  • CD – Dense sand or very stiff clay
  • D – Medium dense sand or stiff clay
  • DE – Loose sand or medium stiff clay
  • E – Very loose sand or soft clay

The Site Class follows Table 20.2-1 ASCEの 7-22. SkyCiv then fetches the seismic hazard values for the location and shows them under USGS地震データ:

パラメータ 意味 How it is used
\( S_{1} \) Mapped maximum considered earthquake (MCE) spectral response acceleration at a 1 s period Hazard input at long periods
\( T_{L} \) 長期移行期間 Sets where the design response spectrum changes from constant velocity to constant displacement
\( S_{DS} \) Design spectral response acceleration at short periods Controls the plateau of the design spectrum and the short-period seismic response coefficient
\( S_{D1} \) Design spectral response acceleration at a 1 s period Controls the long-period branch of the spectrum
\( T_{0} = 0.2 S_{D1} / S_{DS} \) Start of the spectrum plateau Defines the shape of the design response spectrum

You can edit any of these values if your project uses site-specific results, for example from a site response analysis. All of them, together with the Site Class, must have a value before the seismic calculation can run.

Seismic Load Parameters for Buildings

クリック 地震荷重 to open the seismic parameters. The seismic checkbox beside the button is checked automatically when the site values are complete. These are the building inputs:

  • Structure System: the lateral system of the building (steel moment-resisting frames by default, concrete moment-resisting frames, steel eccentrically braced frames, steel buckling-restrained braced frames, or all other structural systems). It sets the coefficients \( C_{t} \) と \( x \) of Table 12.8-2, which are shown in the dropdown for the unit system you selected.
  • 構造物の基本周期, T (または \( T_{a} \)): when you pick a Structure System, SkyCiv fills this field with the approximate period \( T_{a} = C_{t} h_{n}^{x} \), using the roof mean height from Structure Data as \( h_{n} \). You can overwrite it with a period from a dynamic analysis, 例えば SkyCiv S3D Dynamic Frequency Analysis. A longer period lowers the base shear, so check any value you override.
  • 応答修正係数, R: デフォルトは 3.5. Take the value for your seismic force-resisting system from Table 12.2-1 (or Tables 12.14-1, 15.4-1 と 15.4-2 where they apply). The base shear is inversely proportional to R.
  • Redundancy Factor, r: 選択する 1.0 (デフォルト) または 1.3 according to Section 12.3.4. It is used in the diaphragm force calculation.
  • フロアウェイト: a table of Level, Elevation and Weight for each floor. 使用する Add Floor Weights Data to add rows and 晴れ to empty the table. The total weight gives the seismic base shear, and each floor’s weight and height drive the vertical distribution of forces.

How the Parameters Work Together

In the Equivalent Lateral Force procedure, the Site Class and the hazard values \( S_{DS} \) と \( S_{D1} \) define the design response spectrum. The period \( T \) is read on that spectrum to get the seismic response coefficient \( C_{s} \), which is reduced by \( R \) and increased by the importance of the building (from the Risk Category). The seismic base shear is then:

[math] V = C_{s} W [math]

どこ \( W \) is the effective seismic weight from the Floor Weights table. The base shear is distributed over the height of the building in proportion to the weight and elevation of each floor, which gives the force at each level. The redundancy factor \( ρ \) is applied when the diaphragm forces are calculated.

Calculate Loads and Review the Results

クリック 荷重の計算 at the upper right.    地震荷重 results tab shows:

  • Seismic Parameters: every input and derived value used in the calculation.
  • 地震力の鉛直分布: the force at each floor and the base shear.
  • Diaphragm forces: the floor diaphragm design forces.
  • 応答スペクトル: the design response spectrum generated for your site.

始めましょう

自分で試してみたい?

SkyCiv を今すぐ無料でお試しください!

無料でサインアップ

Detailed Seismic Calculation Report

   Detailed Seismic Calculation Report is a Premium feature. It lists every equation, parameter and assumption used in the calculation, so you can check the result and attach it to your design documentation. It is available with a Professional Account or the standalone Load Generator module.

For wind loads on the same project, 見る ASCE 7-22 風荷重の計算.

お手伝いできることはありますか?

×

トップへ戻る