Конструкция соединения торцевой пластины на сдвиг

Shear end plate connection design to AISC 360 covers two sides of one plate. На балке, you check the fillet welds that join the plate to the beam web and the beam web itself in shear. At the support, you check bolt shear, bolt bearing and tear-out on the end plate and the column flange, сдвиг блока, shear yielding and rupture of the plate, plate flexure, and shear and moment interaction. Detailing limits on depth, интервал, edge distance and gage apply on both sides.

На этой странице от начала до конца работает один реальный пример.: a W18x50 beam framing into the flange of a W14x90 column with a 150 kip LRFD reaction. The connection is a 5/16 в х 8 1/2 в х 15 in A36 end plate, welded to the beam web with 1/4 in fillets on both sides and bolted to the column with ten 3/4 in A325-N bolts in two columns of five. Дизайн соответствует AISC 360-16 и Руководство AISC, 15-е издание.. Каждое уравнение записано с его номерами, в том же порядке, что и расчетный лист AISC, в котором SkyCiv Connection Design модуль выдает для этого соединения.

What is a shear end plate connection?

A shear end plate connection is a single plate shop welded square to the end of the beam web and field bolted to the support. The plate fits within the flat part of the beam web, with one column of bolts on each side of the web. It carries the beam’s end shear and is a simple connection under AISC 360-16 Б3.4. The plate is kept thin so it can flex as the beam end rotates, which keeps moment out of the support.

It is different from a moment end plate. А момент связи such as a flush or extended end plate welds the plate to the beam flanges too and uses a much thicker plate. A shear end plate is welded to the web only. It is one type of сдвиговое соединение, alongside the одиночная пластина (shear tab) связь, в double angle connection и single angle connection. Вы можете проверить этот пример непосредственно в end plate connection calculator.

Shear end plate connection design example elevation: A992 W18x50 beam with a PL 5/16 x 8 1/2 Икс 15 A36 end plate welded with 1/4 in E70XX fillets and bolted to the flange of an A992 W14x90 column, Vu = 150 кип

Высота примера соединения. The end plate is welded to the beam web in the shop and bolted to the column flange in the field.

Section A-A through the shear end plate connection showing the PL 5/16 x 8 1/2 Икс 15 end plate with ten 3/4 in A325N bolts in horizontal short-slotted holes at a 5 1/2 в калибре и 3 in row spacing

Section A-A. Two columns of five bolts at a 5 1/2 в норме, с участием 1 1/2 in edge distances all round the plate.

How do you design a shear end plate connection? The steps at a glance

  1. Check the detailing limit at the beam side: the minimum plate depth.
  2. Check the fillet welds from the end plate to the beam web.
  3. Check the beam web in shear yielding.
  4. Check the detailing limits at the support side: интервал, edge distances and gage.
  5. Check the bolt group in shear.
  6. Check bolt bearing and tear-out on the end plate.
  7. Check bolt bearing and tear-out on the column flange.
  8. Combine shear, bearing and tear-out per bolt for the effective group strength.
  9. Check block shear of the end plate.
  10. Check shear yielding and shear rupture of the end plate.
  11. Check end plate flexure using the double coped procedure.
  12. Check shear and moment interaction of the end plate.

Проектирование входных данных для этого примера

Код дизайна: AISC. 360-16 LRFD. Свойства раздела взяты из руководства AISC..

Вещь Символ Стоимость
Factored vertical shear [mathin] V_{u} [mathin] 150 кип
Луч Вы можете заметить, что основное отличие заключается в соединении полок балки с опорной колонной., A992
Beam depth [mathin] d_{bm} [mathin] 18 в
Beam web thickness [mathin] t_{wb} [mathin] 0.355 в
Beam flange width / толщина [mathin] b_{fb},\ t_{fb} [mathin] 7.5 в / 0.57 в
Beam T dimension / kdet [mathin] T_{bm},\ k_{det,bm} [mathin] 15.5 в / 1.25 в
Beam area [mathin] A_{bm} [mathin] 14.7 дюйм²
Beam yield / растягивающее напряжение [mathin] F_{yb},\ F_{ub} [mathin] 50 KSI / 65 KSI
Столбец в., A992
Глубина колонны / толщина полотна [mathin] d_{sup},\ t_{ws} [mathin] 14 в / 0.44 в
Ширина полки колонны / толщина [mathin] b_{fs},\ t_{fs} [mathin] 14.5 в / 0.71 в
Область столбца [mathin] A_{sup} [mathin] 26.5 дюйм²
Выход колонки / растягивающее напряжение [mathin] F_{ys},\ F_{us} [mathin] 50 KSI / 65 KSI
Модуль упругости [mathin] E [mathin] 29000 KSI

 

Вещь Символ Стоимость
Торцевая пластина PL 5/16 Икс 8 1/2 Икс 15, A36
End plate width / глубина / толщина [mathin] b_{p},\ d_{p},\ t_{p} [mathin] 8.5 в / 15 в / 0.3125 в
End plate yield / растягивающее напряжение [mathin] F_{yp},\ F_{up} [mathin] 36 KSI / 58 KSI
Bolts at the column 3/4 in A325-N, single shear
Диаметр болта [mathin] d_{b} [mathin] 0.75 в
Bolt nominal tensile / напряжение сдвига [mathin] F_{nt},\ F_{nv} [mathin] 90 KSI / 54 KSI
Shear planes [mathin] N_{s} [mathin] 1
Holes in end plate / колонка Short-slotted horizontal (HSSL) / стандарт (ЗППП)
Weld at the beam 1/4 в филе, both sides of the web, Е70ХХ
Размер сварного шва / прочность наполнителя [mathin] W,\ F_{EXX} [mathin] 0.25 в / 70 KSI

 

Геометрия Символ Стоимость
Ряды болтов / междурядье [mathin] n_{r},\ s_{r} [mathin] 5 / 3 в
Болтовые колонны / калибр [mathin] n_{c},\ g_{s} [mathin] 2 / 5.5 в
Total number of bolts [mathin] N_{V} [mathin] 10
Vertical edge distance on end plate [mathin] L_{ev} [mathin] 1.5 в
Horizontal edge distance on end plate [mathin] L_{eh} [mathin] 1.5 в

The plate dimensions add up from the drawing. The width is the two 1.5 in edge distances plus the 5.5 в норме, 8.5 в. The depth is the two 1.5 in edge distances plus four 3 в пространствах, 15 в.

шаг 1: Detailing limit at the beam side

The end plate has to be deep enough to brace the beam end against rotation about its own axis and to give the welds enough length. The minimum is half the beam’s T dimension, so for a W18x50 with T = 15.5 in it is 7.75 в.

Лимит детализации Лимит (в) Действительный (в) DCR результат
Minimum connection depth 7.750 15.000 0.517 ПРОХОДЯТ

[math] DCR = \frac{d}{c} = \frac{(7.75)}{(15)} = 0.51667 [math]

Прочность на единицу размера сварного шва 0.517 < 1.0, Прочность на единицу размера сварного шва

шаг 2: Fillet weld from the end plate to the beam web (Aisc 360-16 Дж2.4)

The whole reaction passes from the beam web into the end plate through the two fillet welds, one on each face of the web. Their strength depends on size and length, and the base metal on either side of the weld can limit how much of the weld size counts.

Предел основного металла по размеру сварного шва (Ручное уравнение AISC. 9-2)

This is the largest weld size, in sixteenths of an inch, that the connected parts can support. Each weld line has the full end plate behind it, but the beam web carries a weld on both of its faces, so only half the web thickness is available to each weld. С [mathin] t_{p} = 0.3125\,in [mathin], [mathin] F_{up} = 58\,ksi [mathin], [mathin] t_{wb} = 0.355\,in [mathin] и [mathin] F_{ub} = 65\,ksi [mathin]:

[math] D_{max} = \frac{t_{p} F_{up} \le \frac{t_{wb}}{2} F_{ub}}{3.09\,kip/in \times F_{EXX}/F_{E70XX}} [math]

[math] D_{max} = \frac{(0.3125\,in) \times (58\,ksi) \le (0.1775\,in) \times (65\,ksi)}{(3.09\,kip/in) \times (1)} [math]

[math] D_{max} = 3.7338 [math]

The beam web side gives the smaller value, so only 3.7338/16 в, о 0.233 в, из 1/4 in weld can be counted.

Эффективная длина сварного шва

The weld can only run along the flat part of the web, so its length is the least of the plate depth, the beam’s T dimension, and the beam depth less the cope or kdet zone at the top and bottom. There is no cope, so the kdet of 1.25 in applies at each end. Each of the two weld lines is then reduced by 2W for the end returns. С [mathin] W = 0.25\,in [mathin], [mathin] d_{p} = 15\,in [mathin], [mathin] T_{bm} = 15.5\,in [mathin], [mathin] d_{bm} = 18\,in [mathin] и [mathin] k_{det,bm} = 1.25\,in [mathin]:

[math] L_{w} = 2 \left[ \min\left( d_{p},\, T_{bm},\, d_{bm} – \max\left(D_{ct}, k_{det,bm}\right) – \max\left(D_{cb}, k_{det,bm}\right) \right) – 2W \right] [math]

[math] L_{w} = 2 \times \left[ \min\left( (15\,in),\, (15.5\,in),\, (18\,in) – \max\left((0\,in), (1.25\,in)\right) – \max\left((0\,in), (1.25\,in)\right) \right) – 2 \times (0.25\,in) \right] [math]

[math] L_{w} = 29\,in [math]

Прочность сварного шва

The load runs parallel to the welds, так [mathin] \theta = 0 [mathin] и нет направленного увеличения. С [mathin] F_{EXX} = 70\,ksi [mathin] и [mathin] \phi = 0.75 [mathin]:

[math] \phi R_{n} = \phi\, 0.6\, F_{EXX} \frac{\sqrt{2}}{2} \left( W \le \frac{D_{max}}{16} \right) \left[ 1 + 0.5 \left( \sin\theta \right)^{1.5} \right] L_{w} [math]

[math] \phi R_{n} = (0.75) \times 0.6 \times (70\,ksi) \times \frac{\sqrt{2}}{2} \times \left( (0.25\,in) \le \frac{(3.7338)}{(16)} \right) \times \left[ 1 + 0.5 \times (\sin(0))^{1.5} \right] \times (29\,in) [math]

[math] \phi R_{n} = 150.74\,kip [math]

Прочность на единицу размера сварного шва 150 кип / 150.74 кип = 0.995 < 1.0, Прочность на единицу размера сварного шва

This is the governing check. The weld is only just enough, and making it bigger would not help, because the 0.355 in beam web already limits the usable size to 0.233 в.

шаг 3: Beam web in shear yielding (Aisc 360-16 J4.2)

The reaction travels along the beam web into the welds, so the web itself has to carry the full shear without yielding. The beam is not coped, so the full depth of the beam acts.

[math] A_{gv} = d_{bm}\, t_{wb} = (18\,in) \times (0.355\,in) = 6.39\,in^{2} [math]

С [mathin] F_{yb} = 50\,ksi [mathin] и [mathin] \phi = 1 [mathin]:

[math] \phi R_{n,sy} = \phi\, 0.6\, F_{yb} A_{gv} = (1) \times 0.6 \times (50\,ksi) \times (6.39\,in^{2}) = 191.7\,kip [math]

Прочность на единицу размера сварного шва 150 кип / 191.7 кип = 0.782 < 1.0, Прочность на единицу размера сварного шва

шаг 4: Detailing limits at the support side (Aisc 360-16 J3.3, J3.4, J3.5)

Расположение болтов должно быть поддающимся сборке и соответствовать предположениям, лежащим в основе уравнений прочности.. Болты, затянутые слишком близко, рвутся между отверстиями., края, которые расположены слишком близко, вырываются, and the gage has to leave room for the beam web, the welds and the bolt heads.

Для 3/4 в болте минимальное расстояние составляет [mathin] 2\tfrac{2}{3} d_{b} = 2\,in [mathin] (J3.3) а минимальное краевое расстояние равно 1 в (Таблица J3.4). The end plate has horizontal short slots, and its horizontal edge distance is measured from the end of the slot, поэтому приращение таблицы J3.5 1/8 in raises its minimum to 1.125 в. On the column flange, the horizontal edge distance is what is left of the flange outside the bolts, [mathin] (b_{fs} – g_{s})/2 = (14.5 – 5.5)/2 = 4.5\,in [mathin].

Лимит детализации Лимит (в) Действительный (в) DCR результат
Минимальное расстояние между рядами болтов 2.000 3.000 0.667 ПРОХОДЯТ
Максимальное расстояние между рядами болтов 6.000 3.000 0.500 ПРОХОДЯТ
Plate minimum vertical edge distance 1.000 1.500 0.667 ПРОХОДЯТ
Plate minimum horizontal edge distance 1.125 1.500 0.750 ПРОХОДЯТ
Support minimum horizontal edge distance 1.000 4.500 0.222 ПРОХОДЯТ
Minimum bolt gage at support 4.375 5.500 0.795 ПРОХОДЯТ
Minimum bolt gage at end plate 2.355 5.500 0.428 ПРОХОДЯТ

Для минимального предела соотношение превышает фактическое значение., а для максимума это актуально сверх лимита. The governing row is the minimum bolt gage at the support:

[math] DCR = \frac{d}{c} = \frac{(4.375)}{(5.5)} = 0.79545 [math]

Прочность на единицу размера сварного шва 0.795 < 1.0, Прочность на единицу размера сварного шва

шаг 5: Bolt group shear at the support side (Aisc 360-16 J3.6)

The bolts sit at the face of the column, in line with the reaction, and the two bolt columns are symmetric about the beam web. So the bolt group carries pure shear with no eccentricity, and every bolt takes an equal share.

куда [mathin] \phi = 0.75 [mathin], [mathin] F_{nv} = 54\,ksi [mathin], [mathin] d_{b} = 0.75\,in [mathin], [mathin] N_{s} = 1 [mathin], [mathin] N_{V} = 10 [mathin] и [mathin] h_{f} = 1 [mathin] потому что нет наполнителей (J5.2(а )):

[math] \phi R_{n} = \phi\, F_{nv}\, \frac{\pi}{4} \left( d_{b} \right)^{2} N_{s}\, N_{V}\, h_{f} [math]

[math] \phi R_{n} = (0.75) \times (54\,ksi) \times \frac{\pi}{4} \times \left( (0.75\,in) \right)^{2} \times (1) \times (10) \times (1) [math]

[math] \phi R_{n} = 178.92\,kip [math]

Прочность на единицу размера сварного шва 150 кип / 178.92 кип = 0.838 < 1.0, Прочность на единицу размера сварного шва

шаг 6: Bolt bearing and tear-out on the end plate (Aisc 360-16 J3.10)

Each bolt bears on the edge of its hole in the end plate. The plate either deforms at the hole (несущий, capped at 2.4 Поскольку расстояние до края меньше, чем соседнее расстояние до следующего отверстия под болт) or tears a strip out to the next hole or to the plate’s end (tear-out, 1.2 Поскольку расстояние до края меньше, чем соседнее расстояние до следующего отверстия под болт). The bolt nearest the end of the plate has the shortest clear distance, so it is the weak one.

The slots run horizontally and the load is vertical, so the hole dimension across the member length is the standard [mathin] d_{h} = 0.8125\,in [mathin]. Clear distance for the edge bolt, с участием [mathin] L_{ev} = 1.5\,in [mathin]:

[math] l_{c1} = L_{ev} – \frac{d_{h}}{2} = (1.5\,in) – \frac{(0.8125\,in)}{2} = 1.0938\,in [math]

Свободное расстояние между болтами, с участием [mathin] s_{r} = 3\,in [mathin]:

[math] l_{c2} = s_{r} – d_{h} = (3\,in) – (0.8125\,in) = 2.1875\,in [math]

куда [mathin] t_{p} = 0.3125\,in [mathin], [mathin] F_{up} = 58\,ksi [mathin], [mathin] N_{V} = 10 [mathin], [mathin] n_{r} = 5 [mathin] и [mathin] \phi = 0.75 [mathin]. The bracket is the strength of one line of five bolts, and the factor N_V / n_r = 2 counts both lines:

[math] \phi R_{n,tearout} = \phi \left[ \min\left(1.2\, l_{c1},\, 2.4\, d_{b}\right) t_{p} F_{up} + \min\left(1.2\, l_{c2},\, 2.4\, d_{b}\right) t_{p} F_{up} \left( n_{r} – 1 \right) \right] \left( \frac{N_{V}}{n_{r}} \right) [math]

[math] \phi R_{n,tearout} = (0.75) \times \left[ \min\left(1.2 \times (1.0938\,in),\, 2.4 \times (0.75\,in)\right) \times (0.3125\,in) \times (58\,ksi) + \min\left(1.2 \times (2.1875\,in),\, 2.4 \times (0.75\,in)\right) \times (0.3125\,in) \times (58\,ksi) \times \left( (5) – 1 \right) \right] \times \left( \frac{(10)}{(5)} \right) [math]

[math] \phi R_{n,tearout} = 231.43\,kip [math]

Прочность на единицу размера сварного шва 150 кип / 231.43 кип = 0.648 < 1.0, Прочность на единицу размера сварного шва

Tear-out governs the edge bolt, because 1.2 lc1 is less than 2.4 db. The inner bolts are capped by bearing.

шаг 7: Bolt bearing and tear-out on the column flange (Aisc 360-16 J3.10)

The same check applies to the column flange. The bolts are in the middle of a tall column, with no edge above or below them, so every bolt bears like an inner bolt.

[math] l_{c2} = s_{r} – d_{h} = (3\,in) – (0.8125\,in) = 2.1875\,in [math]

куда [mathin] t_{fs} = 0.71\,in [mathin], [mathin] F_{us} = 65\,ksi [mathin] и [mathin] N_{V} = 10 [mathin]:

[math] \phi R_{n,tearout} = \phi\, \min\left(1.2\, l_{c2},\, 2.4\, d_{b}\right) t_{fs} F_{us}\, N_{V} [math]

[math] \phi R_{n,tearout} = (0.75) \times \min\left(1.2 \times (2.1875\,in),\, 2.4 \times (0.75\,in)\right) \times (0.71\,in) \times (65\,ksi) \times (10) [math]

[math] \phi R_{n,tearout} = 623.03\,kip [math]

Прочность на единицу размера сварного шва 150 кип / 623.03 кип = 0.241 < 1.0, Прочность на единицу размера сварного шва

В 0.71 in column flange is more than twice as thick as the end plate, so bearing on the column is rarely a concern with a thin shear end plate.

шаг 8: Effective strength of the bolt group (Aisc 360-16 J3.6 Commentary)

Срез болта, bearing and tear-out are not really separate checks. Each bolt carries the least of its shear strength and its bearing or tear-out strength in every ply it passes through, and the group strength is the sum of those per-bolt values.

Strength of one bolt in single shear:

[math] \phi r_{v} = \frac{\phi R_{n}}{N_{V}} = \frac{(178.92\,kip)}{(10)} = 17.892\,kip [math]

Bearing and tear-out of one bolt on the end plate, for the edge bolt and an inner bolt:

[math] \phi r_{n1e} = \phi\, \min\left(1.2\, l_{c1},\, 2.4\, d_{b}\right) t_{p} F_{up} = (0.75) \times \min\left(1.2 \times (1.0938\,in),\, 2.4 \times (0.75\,in)\right) \times (0.3125\,in) \times (58\,ksi) = 17.842\,kip [math]

[math] \phi r_{n1i} = \phi\, \min\left(1.2\, l_{c2},\, 2.4\, d_{b}\right) t_{p} F_{up} = (0.75) \times \min\left(1.2 \times (2.1875\,in),\, 2.4 \times (0.75\,in)\right) \times (0.3125\,in) \times (58\,ksi) = 24.469\,kip [math]

Bearing of one bolt on the column flange:

[math] \phi r_{n2} = \phi\, \min\left(1.2\, l_{c2},\, 2.4\, d_{b}\right) t_{fs} F_{us} = (0.75) \times \min\left(1.2 \times (2.1875\,in),\, 2.4 \times (0.75\,in)\right) \times (0.71\,in) \times (65\,ksi) = 62.303\,kip [math]

Bolts are numbered from the top of each line, and the report takes bolt 5 as the edge bolt. The top and bottom edge distances are both 1.5 в, so the edge bolt has the same 1.0938 in clear distance whichever end it is at:

[math] \phi r_{eff,1} = \min\left( \phi r_{v},\, \phi r_{n1i},\, \phi r_{n2} \right) = \min\left( (17.892\,kip),\, (24.469\,kip),\, (62.303\,kip) \right) = 17.892\,kip [math]

[math] \phi r_{eff,2} = \min\left( \phi r_{v},\, \phi r_{n1e},\, \phi r_{n2} \right) = \min\left( (17.892\,kip),\, (17.842\,kip),\, (62.303\,kip) \right) = 17.842\,kip [math]

Болт Срез болта (кип ) Несущий / tear-out, торцевая пластина (кип ) Несущий / tear-out, фланец колонны (кип ) Effective strength (кип )
1 17.89 24.47 62.30 17.89
2 17.89 24.47 62.30 17.89
3 17.89 24.47 62.30 17.89
4 17.89 24.47 62.30 17.89
5 17.89 17.84 62.30 17.84

Sum over one line, с участием [mathin] n_{1} = 4 [mathin] bolts at the inner value and [mathin] n_{2} = 1 [mathin] at the edge value:

[math] \sum \phi r_{eff} = n_{1}\, \phi r_{eff,1} + n_{2}\, \phi r_{eff,2} = (4) \times (17.892\,kip) + (1) \times (17.842\,kip) = 89.411\,kip [math]

[math] \phi R_{n,eff} = \left( \frac{N_{V}}{n_{r}} \right) \sum \phi r_{eff} = \left( \frac{(10)}{(5)} \right) \times (89.411\,kip) = 178.82\,kip [math]

Прочность на единицу размера сварного шва 150 кип / 178.82 кип = 0.839 < 1.0, Прочность на единицу размера сварного шва

Bolt shear governs four bolts in each line, and tear-out on the 5/16 in plate governs the edge bolt by 0.05 кип . That is why the effective strength comes out a fraction below the bolt shear strength in Step 5. You can run the same connection in the free connection design calculator and try a larger edge distance to see the two values meet.

шаг 9: Block shear of the end plate (Aisc 360-16 J4.3)

A block of the end plate can tear out on each side of the beam web: shear along the bolt line to the end of the plate, plus tension across to the plate’s outer edge. That makes two L-shaped blocks, one per bolt column, so the areas below use [mathin] 2t_{p} = 0.625\,in [mathin] and count one bolt column on each side.

Чистая площадь в напряжении. The tension plane runs horizontally, along the slots, so it uses the slot length [mathin] d_{h} = 1\,in [mathin], с участием [mathin] n_{c} = 2 [mathin], [mathin] s_{c} = 0\,in [mathin] и [mathin] L_{eh} = 1.5\,in [mathin]. Каждое отверстие добавляет 1/16 за повреждение во время удара кулаком (Б4.3):

[math] A_{nt} = 2t_{p} \left[ \left( \frac{n_{c}}{2} – 1 \right) s_{c} + L_{eh} – \left( \frac{n_{c}}{2} – 0.5 \right) \left( d_{h} + 0.0625\,in \right) \right] [math]

[math] A_{nt} = (0.625\,in) \times \left[ ((1)-1) \times (0\,in) + (1.5\,in) – ((1) – 0.5) \times ((1\,in) + (0.0625\,in)) \right] = 0.60547\,in^{2} [math]

Общая и чистая площади при сдвиге. The shear plane runs vertically, across the slots, so the net area uses [mathin] d_{h} = 0.8125\,in [mathin]:

[math] A_{gv} = 2t_{p} \left[ L_{ev} + (n_{r}-1)\, s_{r} \right] = (0.625\,in) \times \left[ (1.5\,in) + ((5)-1) \times (3\,in) \right] = 8.4375\,in^{2} [math]

[math] A_{nv} = 2t_{p} \left[ d_{p} – L_{ev} – (n_{r} – 0.5)\left( d_{h} + 0.0625\,in \right) \right] [math]

[math] A_{nv} = (0.625\,in) \times \left[ (15\,in) – (1.5\,in) – ((5) – 0.5) \times ((0.8125\,in) + (0.0625\,in)) \right] = 5.9766\,in^{2} [math]

Блок прочности на сдвиг, с участием [mathin] U_{bs} = 1 [mathin] because each block has a single bolt column and the tension is uniform, [mathin] F_{up} = 58\,ksi [mathin], [mathin] F_{yp} = 36\,ksi [mathin] и [mathin] \phi = 0.75 [mathin]:

[math] \phi R_{n} = \phi \left( 0.6\, F_{up} A_{nv} + U_{bs} F_{up} A_{nt} \le 0.6\, F_{yp} A_{gv} + U_{bs} F_{up} A_{nt} \right) [math]

[math] \phi R_{n} = (0.75) \times \left( 0.6 \times (58\,ksi) \times (5.9766\,in^{2}) + (1) \times (58\,ksi) \times (0.60547\,in^{2}) \le 0.6 \times (36\,ksi) \times (8.4375\,in^{2}) + (1) \times (58\,ksi) \times (0.60547\,in^{2}) \right) [math]

[math] \phi R_{n} = 163.03\,kip [math]

Прочность на единицу размера сварного шва 150 кип / 163.03 кип = 0.920 < 1.0, Прочность на единицу размера сварного шва

The shear yielding side of the equation governs. A36 has a low yield-to-tensile ratio, so the gross shear plane yields before the net shear plane ruptures. This is the second highest ratio in the connection.

шаг 10: Shear yielding and shear rupture of the end plate (Aisc 360-16 J4.2)

The full reaction passes down through the end plate as vertical shear on two planes, по одному с каждой стороны стенки балки. The gross section must not yield, and the net section through the bolt holes must not rupture.

Shear yielding (уравнение. J4-3)

С [mathin] n_{sp} = 2 [mathin] плоскости сдвига:

[math] A_{gv} = d_{p}\, n_{sp}\, t_{p} = (15\,in) \times (0.625\,in) = 9.375\,in^{2} [math]

[math] \phi R_{n,sy} = \phi\, 0.6\, F_{yp} A_{gv} = (1) \times 0.6 \times (36\,ksi) \times (9.375\,in^{2}) = 202.5\,kip [math]

Shear rupture (уравнение. J4-4)

[math] A_{nv} = n_{sp}\, t_{p} \left[ d_{p} – n_{r}\left( d_{h} + 0.0625\,in \right) \right] = (0.625\,in) \times \left[ (15\,in) – (5) \times ((0.8125\,in) + (0.0625\,in)) \right] = 6.6406\,in^{2} [math]

[math] \phi R_{n,sr} = \phi\, 0.6\, F_{up} A_{nv} = (0.75) \times 0.6 \times (58\,ksi) \times (6.6406\,in^{2}) = 173.32\,kip [math]

[math] \phi R_{n} = \min\left( \phi R_{n,sy},\, \phi R_{n,sr} \right) = \min\left( (202.5\,kip),\, (173.32\,kip) \right) = 173.32\,kip [math]

Прочность на единицу размера сварного шва 150 кип / 173.32 кип = 0.865 < 1.0, Прочность на единицу размера сварного шва

шаг 11: End plate flexure using the double coped procedure (Aisc 360-16 F11.2)

The bolts are 2 3/4 in out from the web on each side, so each half of the end plate bends as a short cantilever from the web to its bolt line. A thin plate can buckle sideways before it yields. The AISC Manual handles this with the procedure for a beam coped at both flanges, treating each half of the plate like a beam web with the flanges cut away. The unbraced length is the distance from the face of the web to the bolt line, [mathin] L_{b} = (g_{s} – t_{wb})/2 = (5.5 – 0.355)/2 = 2.5725\,in [mathin].

Range check

куда [mathin] E = 29000\,ksi [mathin], [mathin] F_{yp} = 36\,ksi [mathin], [mathin] d_{p} = 15\,in [mathin] и [mathin] t_{p} = 0.3125\,in [mathin]:

[math] \frac{L_{b} d}{t^{2}} = \frac{(2.5725\,in) \times (15\,in)}{(0.3125\,in)^{2}} = 395.14 [math]

[math] \frac{0.08 E}{F_{y}} = \frac{0.08 \times (29000\,ksi)}{(36\,ksi)} = 64.444 \qquad \frac{1.9 E}{F_{y}} = \frac{1.9 \times (29000\,ksi)}{(36\,ksi)} = 1530.6 [math]

Так [mathin] \frac{0.08E}{F_{y}} \lt \frac{L_{b} d}{t^{2}} \le \frac{1.9E}{F_{y}} [mathin], Оценка емкости сваи. F11-2 applies.

Section moduli of the end plate

[math] Z = \frac{t_{p} \left( d_{p} \right)^{2}}{4} = \frac{(0.3125\,in) \times ((15\,in))^{2}}{4} = 17.578\,in^{3} [math]

[math] S = \frac{t_{p} \left( d_{p} \right)^{2}}{6} = \frac{(0.3125\,in) \times ((15\,in))^{2}}{6} = 11.719\,in^{3} [math]

Lateral-torsional buckling modification factor (Ручное уравнение AISC. 9-15)

The cope depth is taken as zero, [mathin] d_{ct} = 0\,in [mathin]:

[math] C_{b} = \left[ 3 + \ln\left( \frac{L_{b}}{d_{p}} \right) \right] \left( 1 – \frac{d_{ct}}{d_{p}} \right) \ge 1.84 [math]

[math] C_{b} = \left[ 3 + \ln\left( \frac{(2.5725\,in)}{(15\,in)} \right) \right] \times \left( 1 – \frac{(0\,in)}{(15\,in)} \right) \ge 1.84 [math]

[math] C_{b} = 1.84 [math]

Flexural strength

С [mathin] \phi = 0.9 [mathin], and a factor of 2 for the two halves of the plate:

[math] \phi M_{n} = \phi \left[ C_{b} \left[ 1.52 – 0.274 \left( \frac{L_{b} d}{t^{2}} \right) \left( \frac{F_{yp}}{E} \right) \right] F_{yp} S \le F_{yp} Z \right] 2 [math]

[math] \phi M_{n} = (0.9) \times \left[ (1.84) \times \left[ 1.52 – 0.274 \times ((395.14)) \times \left( \frac{(36\,ksi)}{(29000\,ksi)} \right) \right] \times (36\,ksi) \times (11.719\,in^{3}) \le (36\,ksi) \times (17.578\,in^{3}) \right] \times 2 [math]

[math] \phi M_{n} = 94.922\,kip\text{-}ft \;(1139.1\,kip\text{-}in) [math]

The plastic moment cap [mathin] F_{yp} Z [mathin] governs, so buckling does not reduce the strength over this short length.

Equivalent shear capacity

[math] \phi V_{n} = \frac{\phi M_{n}}{L_{b}} = \frac{(94.922\,kip\text{-}ft)}{(2.5725\,in)} = 442.78\,kip [math]

Прочность на единицу размера сварного шва 150 кип / 442.78 кип = 0.339 < 1.0, Прочность на единицу размера сварного шва

шаг 12: Shear and moment interaction of the end plate (Ручное уравнение AISC. 10-5)

The end plate carries shear and bending at the same section at the same time, so the two have to be checked together. The Manual uses a circular interaction between the shear yielding strength and the flexural strength.

The moment in the plate is the reaction times the unbraced length, с участием [mathin] V_{r} = 150\,kip [mathin] и [mathin] L_{b} = 2.5725\,in [mathin]:

[math] M_{r} = V_{r}\, L_{b} = (150\,kip) \times (2.5725\,in) = 32.156\,kip\text{-}ft [math]

С [mathin] \phi V_{n} = 202.5\,kip [mathin] from shear yielding in Step 10 и [mathin] \phi M_{n} = 94.922\,kip\text{-}ft [mathin] from Step 11:

[math] I_{nt} = \left( \frac{V_{r}}{\phi V_{n}} \right)^{2} + \left( \frac{M_{r}}{\phi M_{n}} \right)^{2} [math]

[math] I_{nt} = \left( \frac{(150\,kip)}{(202.5\,kip)} \right)^{2} + \left( \frac{(32.156\,kip\text{-}ft)}{(94.922\,kip\text{-}ft)} \right)^{2} = 0.66346 [math]

Прочность на единицу размера сварного шва 0.66346 / 1.0 знак равно 0.663 < 1.0, Прочность на единицу размера сварного шва

The short lever arm keeps the moment small, so most of the interaction comes from shear.

Summary of the shear end plate connection design checks

Проверка дизайна требовать Вместимость DCR результат
Detailing limits at beam side 7.750 в 15.000 в 0.517 ПРОХОДЯТ
Weld at beam side 150.000 кип 150.739 кип 0.995 ПРОХОДЯТ
Beam web in shear 150.000 кип 191.700 кип 0.782 ПРОХОДЯТ
Detailing limits at support side 4.375 в 5.500 в 0.795 ПРОХОДЯТ
Bolt group shear 150.000 кип 178.924 кип 0.838 ПРОХОДЯТ
Bolt bearing and tear-out, торцевая пластина 150.000 кип 231.434 кип 0.648 ПРОХОДЯТ
Bolt bearing and tear-out, фланец колонны 150.000 кип 623.025 кип 0.241 ПРОХОДЯТ
Effective strength of bolt group 150.000 кип 178.822 кип 0.839 ПРОХОДЯТ
Block shear of end plate 150.000 кип 163.025 кип 0.920 ПРОХОДЯТ
Shear yielding and rupture of end plate 150.000 кип 173.320 кип 0.865 ПРОХОДЯТ
End plate flexure (double coped procedure) 150.000 кип 442.784 кип 0.339 ПРОХОДЯТ
Shear and moment interaction of end plate 0.663 1.000 0.663 ПРОХОДЯТ

The connection passes every check. The weld at the beam side governs at 0.995, because the 0.355 in beam web limits the usable weld size to about 0.233 в. Block shear of the end plate is next at 0.920, then shear rupture of the end plate at 0.865. Plate flexure is far from critical at 0.339, which is typical for a shear end plate: the bolts sit close to the web, so the lever arm is short.

Что изменить, если проверка не удалась

  • Weld at the beam side: a longer weld helps, so use a deeper end plate, up to the beam’s T dimension. A bigger fillet adds nothing once the beam web base metal limit governs. A beam with a thicker web raises that limit.
  • Beam web shear: pick a beam with a thicker or deeper web. The end plate cannot help this check.
  • Bolt shear or effective strength: add a bolt row or use a larger bolt. A325-X (threads excluded) or A490 bolts raise the shear stress.
  • Tear-out on the end plate: increase the vertical edge distance, or use a thicker plate.
  • Блок сдвиг, shear yielding or shear rupture of the end plate: use a thicker or deeper plate. A longer horizontal edge distance also adds to the block shear tension area.
  • Plate flexure or interaction: reduce the gage so L_b is shorter, or use a thicker plate. Keep the plate thin enough to stay flexible, because a stiff end plate starts to act like a moment connection.
  • Gage or edge distance at the support: adjust the gage within the column flange width. The gage has to clear the beam web and its welds on the plate side and suit the column flange on the support side.

Часто задаваемые вопросы

What is the difference between a shear end plate and a moment end plate?

A shear end plate is welded to the beam web only, is thin (5/16 здесь), and is designed to flex so the beam end can rotate. A moment end plate, flush or extended, is also welded to the beam flanges, is much thicker, and uses its bolts in tension to resist the beam’s end moment. This example only carries vertical shear, so it is a simple connection.

Why is there no bolt group eccentricity in this example?

The bolts sit at the face of the column, on the line where the reaction is delivered, and the two bolt columns are placed symmetrically on either side of the beam web. So the bolt group carries pure shear and every bolt takes the same share. The bolt group strength is simply the strength of one bolt times the ten bolts.

Why does the beam web, not the end plate, limit the weld?

Ручное уравнение AISC. 9-2 limits the weld size to what the base metal next to it can carry. The beam web has a fillet weld on both of its faces, so each weld is backed by only half the 0.355 в сети. Each weld line has the full 5/16 in end plate behind it. The web gives the smaller value, 3.7338 шестнадцатые, or about 0.233 в, which is less than the 1/4 in weld that was specified.

Why does the end plate have short-slotted holes?

Horizontal short slots in the end plate give the erector some fit-up tolerance across the beam, which helps when the column or the beam length is slightly off. Because the slots are horizontal and the load is vertical, bearing and tear-out use the standard hole dimension across the slot. The slot length only appears in the block shear tension area and in the 1/8 in edge distance increment from Table J3.5.

How thick should a shear end plate be?

Thin enough to rotate. Часть руководства AISC 10 limits end plates in this kind of simple connection to 1/4 в 3/8 Вы можете заметить, что основное отличие заключается в соединении полок балки с опорной колонной., with a gage of 3 1/2 в 5 1/2 в, so the plate can bend as the beam end rotates. A thicker plate or a narrower gage makes the connection stiffer and starts to pull moment into the column. This example uses a 5/16 in plate at a 5 1/2 в норме.

Which check usually governs a shear end plate connection?

On a beam with a thin web, the weld to the beam web often governs, because the web base metal limits the weld size and the weld length is capped by the beam’s T dimension. On a thicker web the end plate itself, through block shear or shear rupture, usually takes over. In this example the weld governs at 0.995, with block shear of the end plate next at 0.920.

Does this example follow the AISC 15th edition or the AISC 16th edition Manual?

It follows AISC 360-16 и Руководство AISC, 15-е издание., which is written around that Specification. The AISC 16th Edition Manual pairs with the later 360-22 Спецификация. The limit states for a shear end plate connection are the same in both, but clause and page references move, so check them against the edition your project uses.

Как это изменится для AISC ASD вместо LRFD??

Предельные состояния и номинальная прочность идентичны.. With AISC ASD you compare the service-level reaction against the nominal strength divided by a safety factor instead of multiplying by a resistance factor. Коэффициент сопротивления 0.75 становится фактором безопасности 2.00, shear yielding’s 1.00 становится 1.50, and flexure’s 0.90 становится 1.67. Сочетания нагрузок тоже меняются., поэтому спрос ниже.

Design a shear end plate connection for free

Каждое число на этой странице получено из одного решения. Pick the end plate configuration, войти в свой луч, колонка, тарелка, болты, weld and reaction, и просмотрите каждую из этих проверок в своем браузере. Нечего устанавливать.

Модуль SkyCiv Connection Design — это программное обеспечение для проектирования соединений, лежащее в основе этого примера.. Он дает вам полный отчет о расчетах с каждым уравнением и вашими числами в нем., как шаги выше, плюс каждая емкость и DCR, для AISC 360-16 (ЛРФД и АСД) и, как 4100:2020. В калькулятор болтов и сварочный калькулятор прикрыть затворную группу и приварить чеки самостоятельно.

Ссылки

  • Aisc 360-16, Спецификация для зданий из конструкционной стали: Б3.4, Б4.3, F11.2 (уравнение. F11-2), Дж2.4 (уравнение. J2-4), J3.3, J3.4 (Таблица J3.4), J3.5 (Таблица J3.5), J3.6 (уравнение. J3-1) and Commentary, J3.10 (уравнение. J3-6а, J3-6c), J4.2 (уравнение. J4-3, J4-4), J4.3 (уравнение. Дж4-5), J5.2(а ).
  • Руководство по стальным конструкциям AISC, 15й выпуск: Часть 9, уравнение. 9-2 Оценка емкости сваи. 9-15 (страница 9-9); Часть 10, длина сварного шва менее 2w на концах, Оценка емкости сваи. 10-5 (страница 10-90).
  • Проектирование стальных соединений с использованием AISC 360-16
  • Болты и сварные швы в дизайне соединений SkyCiv
Гарольд Муналем, Менеджер по продукту по проектированию соединений SkyCiv

Гарольд Муналем
Менеджер по продукту, Дизайн подключения
10+ лет в проектировании стальных соединений
LinkedIn

Как мы можем помочь?

×

Перейти наверх