When a beam framing into an HSS column also carries an axial force, for a drag strut, a collector or a braced bay, the single plate has to pass that force into the tube wall as well as the end shear. To AISC 360-16 this adds a set of checks to the shear tab design: bearing and tear-out in the axial direction, block shear under axial load, tracción y compresión de la placa, combined interaction, beam web block shear and beam tension rupture, y, most important, the strength of the HSS wall under a force pulling or pushing straight on it.
This page works through one example: a W18x35 beam into the 6 en pared de columna HSS8x6x1/2, con 32 cizalla kip y 93 kip axial (tensión y compresión) under LRFD, diez 1 in A490-SC bolts in two columns and a 3/4 in Grade 50 placa. The shear-only version of this connection is covered in Single Plate to HSS Column Connection Design, so here the shear checks are kept short and the page concentrates on what the axial force adds. Every number comes from the SkyCiv Connection Design calc sheet.
What does the axial force change in a single plate to HSS connection?
A shear tab on its own is a simple conexión a cortante and the HSS wall only sees an eccentric vertical load. An axial force acts at right angles to the wall. In tension it pulls the plate away from the tube and the wall bends like a plate between the corners; in compression it pushes the plate in. Because a tube wall is thin and flexible out of its plane, this is usually where a shear and axial tab on an HSS runs out of strength, long before the bolts or plate do.
The axial force also changes which way the bolts bear. In tension they bear toward the free ends, the end of the plate and the end of the beam; in compression they bear toward the support and the span. The software checks both directions and combines each with the shear. You can run the connection in the calculadora de conexión de placa única.

Elevación de la conexión de ejemplo., with the shear and the axial tension and compression acting at the bolt group.

Sección A-A. La placa tiene orificios horizontales con ranuras cortas y un 1/2 en soldadura de ángulo en ambos lados.

3Vista D de la conexión en SkyCiv Connection Design.
Los pasos de un vistazo
The report runs 28 comprobaciones. The ones in bold are added, or changed, by the axial force:
- Detailing limits at the beam.
- Bolt group in slip, under the resultant of shear and axial.
- Ductilidad de la placa.
- Bearing and tear-out on the plate, el cortante.
- Bearing and tear-out on the plate, tensión axial.
- Bearing and tear-out on the plate, compresión axial.
- Shear and axial interaction, cojinete de placa.
- Bearing and tear-out on the beam web, el cortante.
- Bearing and tear-out on the beam web, tensión axial.
- Bearing and tear-out on the beam web, compresión axial.
- Shear and axial interaction, beam web bearing.
- Block shear of the plate, el cortante.
- Block shear of the plate, axial.
- Shear and axial interaction, plate block shear.
- Shear yielding and rupture of the plate.
- Flexión de la placa.
- Plate tension yielding and rupture.
- Cortante, tension and flexure interaction, fluencia.
- Cortante, tension and flexure interaction, ruptura.
- Compresión de placa.
- Cortante, compression and flexure interaction.
- Cortante en bloque del alma de la viga, axial.
- Ruptura de tensión de la viga.
- Detallando límites en la pared HSS.
- Soldar para desarrollar la placa..
- Weld to the HSS wall, under the resultant.
- Punzonado de pared HSS.
- HSS wall under the axial force.
Entradas de diseño para este ejemplo
El código de diseño es AISC. 360-16 LRFD. The beam and column are the same as in the shear-only example; los tornillos, plate and weld are larger to carry the axial force. How the loads are entered is explained in cargas y combinaciones de cargas.
| Artículo | Símbolo | Valor |
|---|---|---|
| corte factorizado | [mathin] V_{u} [mathin] | 32 kip |
| Tensión axial factorizada | [mathin] T_{u} [mathin] | 93 kip |
| Compresión axial factorizada | [mathin] C_{u} [mathin] | 93 kip |
| Beam | A18x35, ASTM A992 (d = 17.7 in, tw = 0.3 in, un = 10.3 pulgadas², año fiscal / Fu = 50 / 65 ksi) | |
| Columna | HSS8x6x1/2, ASTM A500 Gr.. C (año fiscal / Fu = 50 / 62 ksi) | |
| HSS wall width / design thickness / workable flat | [mathin] b,\ t,\ W_{flat} [mathin] | 6 in / 0.465 in / 4.875 in |
| Artículo | Símbolo | Valor |
|---|---|---|
| plato único | PL 3/4 x 6 1/2 x 15, ASTM A572 Gr.. 50 (año fiscal / Fu = 50 / 65 ksi) | |
| Pernos | 1 en A490-SC, Superficie de contacto clase A | |
| Bolt shear stress / tensión de tracción | [mathin] F_{nv},\ F_{nt} [mathin] | 68 ksi / 113 ksi |
| agujeros | Placa: horizontal de ranura corta (HSSL). viga web: para el (ETS) | |
| Soldar a pared HSS | 1/2 en filete por ambos lados, E70XX | |
| Filas de pernos / espaciado entre filas | [mathin] n_{r},\ s_{r} [mathin] | 5 / 3 in |
| Columnas de pernos / espaciado de columnas | [mathin] n_{c},\ s_{c} [mathin] | 2 / 3 in |
| Weld line to first bolt line | [mathin] a [mathin] | 2 in |
| Edge distances, plate and beam | 1.5 in | |
| Excentricidad del diseño (Mesa manual 10-9) | [mathin] e [mathin] | 3.5 in |
Paso 1: Detallando límites en el lado de la viga (AISC 360-16 J3.3, J3.4)
The same limits as for the shear-only connection, now for a 1 en perno: 2.667 in minimum spacing, 1.25 in minimum edge from Table J3.4, y 1.375 in at the plate’s slotted horizontal edge.
| Límite de detalles | Límite (in) | Actual (in) | DCR | Resultado |
|---|---|---|---|---|
| Minimum bolt row / espaciado de columnas | 2.667 | 3.000 | 0.889 | PASAR |
| Maximum bolt row / espaciado de columnas | 6.000 | 3.000 | 0.500 | PASAR |
| Distancia mínima al borde vertical de la placa | 1.250 | 1.500 | 0.833 | PASAR |
| Distancia mínima al borde horizontal de la placa | 1.375 | 1.500 | 0.917 | PASAR |
| Distancia mínima al borde horizontal de la viga | 1.250 | 1.500 | 0.833 | PASAR |
| Profundidad mínima de conexión | 7.750 | 15.000 | 0.517 | PASAR |
| Profundidad máxima de conexión | 16.000 | 15.000 | 0.938 | PASAR |
[math] DCR = \frac{15\,in}{16\,in} = 0.938 [math]
DCR = 0.938 < 1.0, OK
Paso 2: Bolt group in slip under shear and axial (AISC 360-16 J3.8)
With slip-critical bolts the group is designed against slip, Eq. J3-4, for the resultant of the shear and the axial force. La excentricidad es 3.5 in from Manual Table 10-9, and the ICOR coefficient for the inclined load on the 2 x 5 group is C = 8.41 (the IC converges at x = -0.78739 in, y = 13.997 in).
| Tornillo | R (kip) | Rx (kip) | Ry (kip) | Minnesota (pollo en) |
|---|---|---|---|---|
| 1 | 18.06 | 18.03 | 1.01 | 253.19 |
| 2 | 17.66 | 17.62 | 1.26 | 194.75 |
| 3 | 16.84 | 16.76 | 1.65 | 135.35 |
| 4 | 15.09 | 14.91 | 2.35 | 76.35 |
| 5 | 11.07 | 10.30 | 4.06 | 23.76 |
| 6 | 18.10 | 17.47 | 4.73 | 262.47 |
| 7 | 17.77 | 16.80 | 5.79 | 206.67 |
| 8 | 17.13 | 15.48 | 7.33 | 151.58 |
| 9 | 15.97 | 12.73 | 9.65 | 100.15 |
| 10 | 14.35 | 6.69 | 12.69 | 61.43 |
[math] R_{u} = \sqrt{V_{u}^{2} + T_{u}^{2}} = \sqrt{32^{2} + 93^{2}} = 98.351\,kip [math]
[math] \phi R_{n} = \phi\, \mu\, D_{u}\, h_{f}\, T_{b}\, N_{s}\, C = (0.85) \times (0.3) \times (1.13) \times (1) \times (64\,kip) \times (1) \times (8.41) = 155.09\,kip [math]
DCR = 98.351 kip / 155.09 salto = 0.634 < 1.0, OK
Paso 3: Ductilidad de la placa (Página del Manual AISC 10-89)
Unlike the shear-only example, this layout does need the check. The moment coefficient of the group is C’ = 38.669 in:
[math] M_{max} = \frac{F_{nv}}{0.9}\, \frac{\pi}{4} d_{b}^{2}\, C’ = \frac{68\,ksi}{0.9} \times \frac{\pi}{4} (1\,in)^{2} \times (38.669\,in) = 191.22\,kip\text{-}ft [math]
[math] t_{max} = \frac{6 M_{max}}{F_{yp} d_{p}^{2}} = \frac{6 \times (191.22\,kip\text{-}ft)}{(50\,ksi) \times (15\,in)^{2}} = 1.2238\,in [math]
DCR = 0.75 in / 1.2238 en = 0.613 < 1.0, OK
Paso 4: Plate bearing and tear-out under shear (AISC 360-16 J3.10)
As in the shear-only example, con [mathin] d_{h} = 1.125\,in [mathin], an edge clear distance of 0.9375 en y 1.875 in between bolts, scaled by C over the five bolts in a line:
[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.75 \times 65 + \min(1.2 \times 1.875, 2.4) \times 0.75 \times 65 \times 4 \right] \times \frac{8.41}{5} = 622.67\,kip [math]
DCR = 32 kip / 622.67 salto = 0.051 < 1.0, OK
Paso 5: Plate bearing and tear-out under axial tension (AISC 360-16 J3.10)
Under tension the bolts bear on the plate toward its free end. The hole dimension along the slot is [mathin] d_{h} = 1.3125\,in [mathin], entonces las distancias claras son:
[math] l_{c1} = L_{eh\_pl} – \frac{d_{h}}{2} = 1.5 – 0.65625 = 0.84375\,in, \qquad l_{c2} = s_{c} – d_{h} = 1.6875\,in [math]
Along the axial direction there are two bolts in each row, the outer one at the edge and the inner one behind it. The sum is scaled by C over the two bolt columns:
[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.84375, 2.4) \times 0.75 \times 65 + \min(1.2 \times 1.6875, 2.4) \times 0.75 \times 65 \times (2 – 1) \right] \times \frac{8.41}{2} = 467\,kip [math]
DCR = 93 kip / 467 salto = 0.199 < 1.0, OK
Paso 6: Plate bearing and tear-out under axial compression (AISC 360-16 J3.10)
Under compression the bolts bear on the plate toward the support. The edge distance for the bolt nearest the wall is the 2 en la distancia de soldadura a perno:
[math] l_{c1} = a – \frac{d_{h}}{2} = 2 – 0.65625 = 1.3438\,in, \qquad l_{c2} = 1.6875\,in [math]
[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 1.3438, 2.4) \times 0.75 \times 65 + \min(1.2 \times 1.6875, 2.4) \times 0.75 \times 65 \times (2 – 1) \right] \times \frac{8.41}{2} = 559.25\,kip [math]
DCR = 93 kip / 559.25 salto = 0.166 < 1.0, OK
Paso 7: Shear and axial interaction of plate bearing
The axial direction with the larger ratio of load to bearing strength is used, here tension:
[math] \left( \frac{V_{u}}{\phi R_{n,V}} \right)^{2} + \left( \frac{T_{u}}{\phi R_{n,T}} \right)^{2} = \left( \frac{32}{622.67} \right)^{2} + \left( \frac{93}{467} \right)^{2} = 0.042299 [math]
DCR = 0.042 < 1.0, OK
Paso 8: Beam web bearing and tear-out under shear (AISC 360-16 J3.10)
[math] \phi R_{n} = (0.75) \times \min(1.2 \times 1.875, 2.4) \times (0.3\,in) \times (65\,ksi) \times (8.41) = 276.74\,kip [math]
DCR = 32 kip / 276.74 salto = 0.116 < 1.0, OK
Paso 9: Beam web bearing and tear-out under axial tension (AISC 360-16 J3.10)
Under tension the bolts bear on the beam web toward the end of the beam, so the edge bolt uses the 1.5 in beam horizontal edge distance:
[math] l_{c1} = 1.5 – \frac{1.125}{2} = 0.9375\,in, \qquad l_{c2} = 3 – 1.125 = 1.875\,in [math]
[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.3 \times 65 + \min(1.2 \times 1.875, 2.4) \times 0.3 \times 65 \times (2 – 1) \right] \times \frac{8.41}{2} = 207.56\,kip [math]
DCR = 93 kip / 207.56 salto = 0.448 < 1.0, OK
Paso 10: Beam web bearing and tear-out under axial compression (AISC 360-16 J3.10)
Under compression the bolts bear toward the span, donde la web es continua. El perno más lejano no tiene borde más allá, so it takes full bearing, 2.4 d t Fu:
[math] \phi R_{n} = (0.75) \left[ 2.4 \times 1 \times 0.3 \times 65 + \min(1.2 \times 1.875, 2.4) \times 0.3 \times 65 \times (2 – 1) \right] \times \frac{8.41}{2} = 285.97\,kip [math]
DCR = 93 kip / 285.97 salto = 0.325 < 1.0, OK
Paso 11: Shear and axial interaction of beam web bearing
Tension governs again:
[math] \left( \frac{32}{276.74} \right)^{2} + \left( \frac{93}{207.56} \right)^{2} = 0.21414 [math]
DCR = 0.214 < 1.0, OK
Paso 12: Plate block shear under shear (AISC 360-16 J4.3)
The block runs down the two bolt lines and out to the free edge. The report takes [mathin] U_{bs} = 0.5 [mathin] for this two-column layout:
[math] A_{nt} = 1.8281\,in^{2}, \quad A_{gv} = 10.125\,in^{2}, \quad A_{nv} = 6.1172\,in^{2} [math]
[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 6.1172 + 0.5 \times 65 \times 1.8281 \le 0.6 \times 50 \times 10.125 + 0.5 \times 65 \times 1.8281 \right) = 223.49\,kip [math]
DCR = 32 kip / 223.49 salto = 0.143 < 1.0, OK
Paso 13: Plate block shear under axial load (AISC 360-16 J4.3)
Under the axial force the block tears out in the other direction: tension across the bolt rows to one plate edge, and shear along the outer bolt row to the plate end.
[math] A_{nt} = 0.75 \left[ (5 – 1) \times 3 + 1.5 – 4.5 \times (1.1875) \right] = 6.1172\,in^{2} [math]
[math] A_{gv} = 0.75 \left[ 1.5 + (2 – 1) \times 3 \right] = 3.375\,in^{2} [math]
[math] A_{nv} = 0.75 \left[ 6.5 – 2 – 1.5 \times (1.3125 + 0.0625) \right] = 1.8281\,in^{2} [math]
[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 1.8281 + 65 \times 6.1172 \le 0.6 \times 50 \times 3.375 + 65 \times 6.1172 \right) = 351.69\,kip [math]
DCR = 93 kip / 351.69 salto = 0.264 < 1.0, OK
Paso 14: Shear and axial interaction of plate block shear
[math] \left( \frac{32}{223.49} \right)^{2} + \left( \frac{93}{351.69} \right)^{2} = 0.090431 [math]
DCR = 0.090 < 1.0, OK
Paso 15: Plate shear yielding and rupture (AISC 360-16 J4.2)
[math] \phi R_{n\_sy} = 1.0 \times 0.6 \times 50 \times 11.25 = 337.5\,kip, \qquad \phi R_{n\_sr} = 0.75 \times 0.6 \times 65 \times 6.7969 = 198.81\,kip [math]
DCR = 32 kip / 198.81 salto = 0.161 < 1.0, OK
Paso 16: Flexión de la placa mediante el procedimiento de doble viga recortada. (AISC 360-16 F11.2)
The same procedure as the shear-only example, sobre el 2 desde la soldadura hasta la línea de pernos. With Lb d / t² = 53.333, entre 46.4 y 1102, Eq. F11-2 applies and the plate reaches its plastic moment:
[math] \phi M_{n} = 0.9 \times \min\left[ C_{b} \left( 1.52 – 0.274 \times 53.333 \times \frac{50}{29000} \right) \times 50 \times 28.125,\; 50 \times 42.188 \right] = 158.2\,kip\text{-}ft \;\Rightarrow\; \phi V_{n} = 949.22\,kip [math]
[math] Z_{net} = 25.892\,in^{3}, \qquad \phi M_{n} = 0.75 \times 65 \times 25.892 = 105.19\,kip\text{-}ft \;\Rightarrow\; \phi V_{n} = 631.11\,kip [math]
DCR = 32 kip / 631.11 salto = 0.051 < 1.0, OK
Paso 17: Plate tension yielding and rupture (AISC 360-16 J4.1)
The plate is a tension member for the axial force, checked on its full 15 a fondo:
[math] \phi R_{n\_ty} = 0.9 \times F_{yp}\, t_{p}\, d_{p} = 0.9 \times 50 \times 0.75 \times 15 = 506.25\,kip [math]
[math] \phi R_{n\_tr} = 0.75 \times F_{up}\, t_{p} \left[ d_{p} – n_{r} (d_{h} + 0.0625) \right] = 0.75 \times 65 \times 0.75 \left[ 15 – 5 \times (1.1875) \right] = 331.35\,kip [math]
DCR = 93 kip / 331.35 salto = 0.281 < 1.0, OK
Paso 18: Cortante, tension and flexure interaction, fluencia (Parte del manual AISC 10)
[math] \left( \frac{T_{u}}{2 \phi R_{n\_ty}} + \frac{V_{u}}{\phi V_{n}} \right)^{2} + \left( \frac{V_{u}}{\phi R_{n\_sy}} \right)^{2} = \left( \frac{93}{2 \times 506.25} + \frac{32}{949.22} \right)^{2} + \left( \frac{32}{337.5} \right)^{2} = 0.024756 [math]
DCR = 0.025 < 1.0, OK
Paso 19: Cortante, tension and flexure interaction, ruptura (Parte del manual AISC 10)
[math] \left( \frac{T_{u}}{\phi R_{n\_tr}} + \frac{8 V_{u}}{9 \phi V_{n}} \right)^{2} + \left( \frac{V_{u}}{\phi R_{n\_sr}} \right)^{2} = \left( \frac{93}{331.35} + \frac{8 \times 32}{9 \times 631.11} \right)^{2} + \left( \frac{32}{198.81} \right)^{2} = 0.13202 [math]
DCR = 0.132 < 1.0, OK
Paso 20: Compresión de placa (AISC 360-16 J4.4)
KL/r of the plate is no more than 25, entonces ecuación. J4-6 applies with no buckling reduction:
[math] \phi R_{n} = 0.9\, F_{yp}\, t_{p}\, d_{p} = 0.9 \times 50 \times 0.75 \times 15 = 506.25\,kip [math]
DCR = 93 kip / 506.25 salto = 0.184 < 1.0, OK
Paso 21: Cortante, compression and flexure interaction (Parte del manual AISC 10)
[math] \left( \frac{C_{u}}{2 \phi R_{n}} + \frac{V_{u}}{\phi V_{n}} \right)^{2} + \left( \frac{V_{u}}{\phi R_{n\_sy}} \right)^{2} = \left( \frac{93}{2 \times 506.25} + \frac{32}{949.22} \right)^{2} + \left( \frac{32}{337.5} \right)^{2} = 0.024756 [math]
DCR = 0.025 < 1.0, OK
Paso 22: Beam web block shear under axial load (AISC 360-16 J4.3)
The tension force can also tear a block out of the beam web: tension across the five bolt rows and shear along the top and bottom rows to the beam end.
[math] A_{nt} = 0.3 \left[ (5 – 1) \times 3 – (5 – 1) \times (1.1875) \right] = 2.175\,in^{2} [math]
[math] A_{gv} = 2 \times 0.3 \left[ 1.5 + 3 \right] = 2.7\,in^{2}, \qquad A_{nv} = 2 \times 0.3 \left[ 3 + 1.5 – 1.5 \times (1.1875) \right] = 1.6313\,in^{2} [math]
[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 1.6313 + 65 \times 2.175 \le 0.6 \times 50 \times 2.7 + 65 \times 2.175 \right) = 153.75\,kip [math]
DCR = 93 kip / 153.75 salto = 0.605 < 1.0, OK
Paso 23: Ruptura de tensión de la viga (AISC 360-16 D3, J4.1)
Sólo la web está atornillada., so shear lag reduces the effective net area of the beam. The report uses U = 0.73655 from Table D3.1 case 2:
[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.73655 \left[ 10.3 – 5 \times (1.125 + 0.0625) \times 0.3 \right] = 305.88\,kip [math]
DCR = 93 kip / 305.88 salto = 0.304 < 1.0, OK
Paso 24: Detallando límites en la pared HSS
The weld-on-flat and slenderness values are the module’s limits for a single plate on an HSS wall.
| Límite de detalles | Límite (in) | Actual (in) | DCR | Resultado |
|---|---|---|---|---|
| Tamaño máximo de soldadura de filete por espacio libre de viga | 0.500 | 0.500 | 1.000 | PASAR |
| Tamaño máximo de soldadura de filete por plano trabajable HSS | 1.538 | 0.500 | 0.325 | PASAR |
| Esbeltez máxima de pared HSS b/t | 33.716 | 9.903 | 0.294 | PASAR |
El 1/2 in weld exactly fills the 1/2 en espacio libre para vigas, lo cual está permitido:
[math] DCR = \frac{0.5\,in}{0.5\,in} = 1.000 [math]
DCR = 1.000, OK
Paso 25: Soldadura necesaria para desarrollar la placa única. (Página del Manual AISC 10-87)
[math] W_{duc} = \frac{5}{8} \times (0.75\,in) = 0.46875\,in [math]
DCR = 0.46875 in / 0.5 en = 0.938 < 1.0, OK
Paso 26: Fillet weld strength to the HSS wall under the resultant (AISC 360-16 J2.4)
The weld now carries the resultant of the shear and the axial force, at an angle to its axis. That angle earns the directional strength increase of Eq. J2-5, which a pure shear load on a vertical weld does not get:
[math] \theta = 71.012^{\circ}, \qquad D_{max} = \frac{(0.375)(65) \le (0.465)(62)}{3.09} = 7.8883, \qquad L_{w} = 2 \left[ 15 – 2 \times 0.5 \right] = 28\,in [math]
[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.5, \frac{7.8883}{16}\right) \times \left[ 1 + 0.5 \sin^{1.5}(71.012) \right] \times 28 = 448.85\,kip [math]
DCR = 98.351 kip / 448.85 salto = 0.219 < 1.0, OK
Paso 27: Punzonado de pared HSS (Ecuación manual AISC. 10-7b, página 10-153)
[math] \phi R_{n} = \frac{0.75 \times 62 \times 0.465 \times 15^{2}}{5 \times 3.5} = 278\,kip [math]
DCR = 32 kip / 278 salto = 0.115 < 1.0, OK
Paso 28: HSS wall under the axial force
This is the check the axial force exists for. The plate pulls (or pushes) on the middle of the tube wall, and the wall resists by forming a yield line pattern across its workable flat. The report uses the yield line expression it attributes to R. Kapp, which is the software’s method for this limit state:
[math] \phi R_{n} = 0.75 \left[ \frac{F_{ys}\, t^{2}\, d_{p}}{0.5 (W_{flat} – t_{p})} + 4 F_{ys}\, t^{2} \sqrt{1 + \frac{t_{p}}{W_{flat} – t_{p}}} \right] [math]
[math] \phi R_{n} = 0.75 \left[ \frac{50 \times 0.465^{2} \times 15}{0.5 \times (4.875 – 0.75)} + 4 \times 50 \times 0.465^{2} \times \sqrt{1 + \frac{0.75}{4.875 – 0.75}} \right] = 94.23\,kip [math]
DCR = 93 kip / 94.23 salto = 0.987 < 1.0, OK
The first term grows with the plate depth and falls as the workable flat gets wider, and both terms grow with the square of the wall thickness. That is why the wall, not the bolts or the plate, sets the axial capacity of this connection.
Resumen de comprobaciones de diseño.
| Verificación de diseño | Demanda | Capacidad | DCR | Resultado |
|---|---|---|---|---|
| Detalle en el lado de la viga | 15 a fondo | 16 en máximo | 0.938 | PASAR |
| Bolt group in slip (resultante) | 98.351 kip | 155.09 kip | 0.634 | PASAR |
| Ductilidad de la placa | 0.75 in | 1.2238 in | 0.613 | PASAR |
| Rodamiento de placa, el cortante | 32 kip | 622.67 kip | 0.051 | PASAR |
| Rodamiento de placa, tensión axial | 93 kip | 467 kip | 0.199 | PASAR |
| Rodamiento de placa, compresión axial | 93 kip | 559.25 kip | 0.166 | PASAR |
| Plate bearing interaction | 0.042 | PASAR | ||
| Cojinete del alma de la viga, el cortante | 32 kip | 276.74 kip | 0.116 | PASAR |
| Cojinete del alma de la viga, tensión axial | 93 kip | 207.56 kip | 0.448 | PASAR |
| Cojinete del alma de la viga, compresión axial | 93 kip | 285.97 kip | 0.325 | PASAR |
| Beam web bearing interaction | 0.214 | PASAR | ||
| Cortante en bloque de la placa, el cortante | 32 kip | 223.49 kip | 0.143 | PASAR |
| Cortante en bloque de la placa, axial | 93 kip | 351.69 kip | 0.264 | PASAR |
| Interacción de corte del bloque de placas | 0.090 | PASAR | ||
| Plate shear yielding and rupture | 32 kip | 198.81 kip | 0.161 | PASAR |
| Flexión de la placa | 32 kip | 631.11 kip | 0.051 | PASAR |
| Plate tension | 93 kip | 331.35 kip | 0.281 | PASAR |
| Interacción, tension yielding | 0.025 | PASAR | ||
| Interacción, tension rupture | 0.132 | PASAR | ||
| Compresión de placa | 93 kip | 506.25 kip | 0.184 | PASAR |
| Interacción, compresión | 0.025 | PASAR | ||
| Cizalla de bloque de alma de viga, axial | 93 kip | 153.75 kip | 0.605 | PASAR |
| Ruptura de tensión de la viga | 93 kip | 305.88 kip | 0.304 | PASAR |
| Detallado en pared HSS | 0.5 en soldadura | 0.5 en máximo | 1.000 | PASAR |
| Soldar para desarrollar placa. | 0.46875 in | 0.5 in | 0.938 | PASAR |
| Soldar a pared HSS (resultante) | 98.351 kip | 448.85 kip | 0.219 | PASAR |
| Punzonado de pared HSS | 32 kip | 278 kip | 0.115 | PASAR |
| HSS wall under axial | 93 kip | 94.23 kip | 0.987 | PASAR |
La conexión pasa todos los controles.. The HSS wall under the 93 kip axial force governs at 0.987, and the next strength checks are the bolt group in slip (0.634) and block shear of the beam web (0.605). Everything in the plate is lightly loaded. The two ratios at 0.938 y 1.000 are detailing and weld sizing rules, not load against capacity.
Qué cambiar si falla un cheque
- HSS wall under axial: this is the usual limit. A thicker HSS wall helps most, because the strength grows with the square of the wall thickness. A deeper plate also helps. If neither can change, the axial force needs a different connection type.
- Bolt slip or bearing: add bolt rows or a bolt column, o use un perno más grande. For bearing under tension, a larger edge distance to the free end helps.
- Beam web block shear or beam tension rupture: add bolt rows to lengthen the block and raise U, or use a beam with a thicker web.
- Plate tension, compresión o corte en bloque: hacer la placa más profunda o más gruesa, while keeping the ductility check below 1.0.
- Soldar: a larger weld, as long as it fits within the beam clearance and on the workable flat.
Auto Design is available for the single plate connection to an HSS column with shear and axial load. Cambia los tornillos, placa y soldaduras hasta que pase cada control., y mantiene a sus miembros y cargas como se ingresaron. Ver el Diseño automático página para las preferencias con las que funciona.
Preguntas frecuentes
Why are the bolts slip-critical in this example?
A beam carrying both shear and an axial force that reverses between tension and compression is a typical case for slip-critical bolts, so the joint does not slip back and forth through the hole clearance. The report then checks the group against slip with Eq. J3-4 under the resultant of the two forces.
Why does the report check bearing in two axial directions?
In tension the bolts bear toward the free end of the plate and the end of the beam, where the edge distance is short. In compression they bear toward the support and the span, where the plate edge is the weld line and the beam web is continuous. The two give different tear-out strengths, so both are checked, and the interaction uses the direction with the larger ratio.
Why is the weld stronger under the combined load than under shear alone?
A fillet weld loaded at an angle to its axis is stronger than one loaded along it, por el factor 1 + 0.5 sin^1.5 of the angle in Eq. J2-5. The resultant here is at 71 degrees to the weld, which raises the weld strength by about 46%.
How does the shear-only connection compare?
The shear-only example, Diseño de conexión de placa única a columna HSS, uses three 3/4 in bolts and a 3/8 in plate on the same beam and tube, and is governed by bolt shear at 0.660. The axial force here needs ten 1 in bolts and a 3/4 en plato, and the tube wall becomes the limit.
Can the axial force be larger with this tube?
Not by much. A 93 kip the HSS wall check is already at 0.987. For a larger axial force, use un tubo de paredes más gruesas o una placa más profunda.
Design a shear and axial single plate to HSS column connection for free
Cada número en esta página proviene de una solución.. Elija la conexión de placa única a una columna HSS, entra en tu rayo, tubo, tornillos, carga cortante y axial, y mira cada una de estas comprobaciones en tu navegador. No hay nada que instalar.
El módulo SkyCiv Connection Design es el software de diseño de conexiones detrás de este ejemplo.. Le brinda el informe de cálculo completo con cada ecuación y sus números en ella., como los pasos anteriores, más todas las capacidades y DCR, según AISC 360-22 y AISC 360-16 (LRFD y TEA) y AS 4100:2020. El calculadora de pernos y calculadora de soldadura Cubra el grupo de tornillos y verifique las soldaduras por su cuenta..
Referencias
- AISC 360-16, Especificación para edificios de acero estructural: D3 (Tabla D3.1), F11.2 (Eq. F11-2), J2.4 (Eq. J2-4, J2-5), J3.3, J3.4 (Tabla J3.4), J3.5 (Tabla J3.5), J3.8 (Eq. J3-4), J3.10 (Eq. J3-6a, J3-6c), J4.1 (Eq. J4-1, J4-2), J4.2 (Eq. J4-3, J4-4), J4.3 (Eq. J4-5), J4.4 (Eq. J4-6).
- Manual de construcción en acero AISC, 15ª edición: Parte 9, Eq. 9-2, 9-4 y 9-15; Parte 10, Tabla 10-9, paginas 10-87 y 10-89 (Eq. 10-3, 10-4), Eq. 10-7b (página 10-153); Parte 15, Tabla 15-3.
- HSS wall under axial load: yield line analysis by R. Kapp, as used in the report.
- Cómo diseñar una conexión de corte de placa única (columna en forma de W)
- Diseño de conexiones de acero utilizando AISC. 360-16
Harold Munalem
Gerente de producto, Connection Design
10+ años en el diseño de conexiones de acero
LinkedIn