To design a bolted flange plate moment connection to AS 4100, you turn the beam end moment into a tension and compression force pair at the flanges, then follow each flange force from the beam flange, through the bolts and the flange plate, into the weld and the column. The web side plate is a separate shear connection that carries the vertical shear. Both are checked against their detailing limits first.
Esta página funciona a través de un ejemplo de principio a fin.: a 460 UB 74.6 beam joined to the flange of a 310 UC 158 column with 25 mm Grado 300 placas de ala, eight M20 8.8/S bolts per flange and a 10 mm web side plate. It is designed to AS 4100:2020 por un momento de 70 kNm, una cizalla de 80 kN and an axial envelope of 60 kN tension and 90 kN compression. Cada ecuación está escrita con sus números., en el mismo orden que el informe de cálculo que el SkyCiv Connection Design El módulo produce para ello.. El alcance y las convenciones del AS 4100 módulo están en el diseño de conexiones de acero usando AS 4100:2020 página.
¿Qué es una conexión de momento de placa de brida??
A flange plate moment connection has a plate on the top and bottom flanges of the beam. Each plate is fillet welded to the column flange in the shop and bolted to the beam flange on site, so the flange forces from the moment pass through the plates in tension or compression. A web side plate, welded to the column and bolted to the beam web, soporta el cortante. Because the field joint is bolted, the beam can be erected without site welding.
It is a rigid connection, entonces como 4100 Cláusula 9.1.4 asks for a minimum design moment as well as the design actions from the analysis. The other AS 4100 moment connections in the module do the same job with an end plate welded to the beam. Puedes consultar este directamente en el calculadora de conexión de placa de brida.
In this example each flange plate has four rows of two bolts, con un 75 mm pitch along the beam and a 110 mm gauge across it.

Elevación de la conexión de ejemplo.. The flange plates are welded to the column flange with 10 mm fillets, and the web side plate carries the shear.

Sección A-A, a plan of the flange plate. The first bolt row is 70 mm from the face of the column.

La misma conexión en la vista 3D de SkyCiv Connection Design.
Flange plate moment connection design: los pasos de un vistazo
- Verifique los límites detallados de la placa de brida: paso, indicador, edge distances and weld size.
- Establecer el momento del diseño, no menos que la Cláusula 9.1.4 mínimo, encontrar las fuerzas en las bridas, and check the bolts in shear.
- Check the bolts in bearing on the flange plate and the beam flange.
- Check the weld of the flange plate to the column.
- Check block shear of the flange plate and of the beam flange.
- Check the flange plate in tension and in compression, and the beam flange in tension.
- Check the section moment capacity of the beam at the flange bolt holes.
- Check the column flange and web at the flange plate.
- Check the web side plate shear connection: detallado, soldar, tornillos, plate and beam web.
Entradas de diseño para este ejemplo
El código de diseño es AS. 4100:2020, con propiedades de sección de la base de datos de secciones australiana. El límite elástico de cada pieza depende de su grado y espesor.: 300 MPa para el haz, 280 MPa para la columna con su 25 brida mm, 280 MPa para el 25 mm flange plate and 310 MPa para el 10 mm web side plate.
| Artículo | Símbolo | Valor |
|---|---|---|
| Cortante (año fiscal) | [mathin] V^{*} [mathin] | 80 kN |
| Axial (FX), sobre | [mathin] N^{*}_{t},\ N^{*}_{c} [mathin] | 60 kN tension / 90 kN compression |
| Momento del eje mayor (Mz) | [mathin] M^{*}_{x} [mathin] | 70 kNm |
| Beam | 460 UB 74.6, AS / NZS 3679.1 Gr.300 | |
| Profundidad del haz / espesor de la red | [mathin] d_{bm},\ t_{wb} [mathin] | 457 mm / 9.1 mm |
| Ancho del ala de la viga / grosor | [mathin] b_{fb},\ t_{fb} [mathin] | 190 mm / 14.5 mm |
| Área del haz / módulo de sección plástica | [mathin] A_{bm},\ S_{x} [mathin] | 9520 mm² / 1.66 x 10⁶ mm³ |
| Rendimiento del haz / resistencia a la tracción | [mathin] f_{yb},\ f_{ub} [mathin] | 300 MPa / 440 MPa |
| Columna | 310 UC 158, AS / NZS 3679.1 Gr.300 | |
| Profundidad de la columna / espesor de la red | [mathin] d_{sup},\ t_{ws} [mathin] | 327 mm / 15.7 mm |
| Ancho del ala de la columna / grosor | [mathin] b_{fs},\ t_{fs} [mathin] | 311 mm / 25 mm |
| Radio de raíz de columna | [mathin] r_{s} [mathin] | 16.5 mm |
| Rendimiento de la columna / resistencia a la tracción | [mathin] f_{ys},\ f_{us} [mathin] | 280 MPa / 440 MPa |
| módulo elástico | [mathin] E [mathin] | 200000 MPa |
| Placas de ala (top and bottom) | Símbolo | Valor |
|---|---|---|
| Placa de ala | PL 25 x 210 x 345, AS / NZS 3678 Gr.300 | |
| Ancho de la placa / longitud / grosor | [mathin] b_{p},\ l_{p},\ t_{p} [mathin] | 210 mm / 345 mm / 25 mm |
| Rendimiento de la placa / resistencia a la tracción | [mathin] f_{yp},\ f_{up} [mathin] | 280 MPa / 430 MPa |
| Bolts to the beam flange | M20 8,8/S, Hilos incluidos en el plano de corte. | |
| Diámetro del perno / resistencia mínima a la tracción | [mathin] d_{ff},\ f_{uf} [mathin] | 20 mm / 830 MPa |
| Holes in plate and beam flange | [mathin] d_{h} [mathin] | Nominal, 22 mm |
| Filas de pernos / paso de fila | [mathin] n_{p},\ s_{p} [mathin] | 4 / 75 mm |
| Columnas de pernos / indicador | [mathin] n_{g},\ s_{g} [mathin] | 2 / 110 mm |
| Support face to first bolt row | [mathin] l [mathin] | 70 mm |
| Edge distances on plate (final / lado) | [mathin] l_{ev\_fp},\ l_{eh\_fp} [mathin] | 50 mm / 50 mm |
| Edge distances on beam flange (final / lado) | [mathin] l_{ev\_f},\ l_{eh\_f} [mathin] | 40 mm / 50 mm |
| Soldar al ala de la columna | 10 filete mm, E49XX, SP | |
| Tamaño de soldadura / resistencia del metal de soldadura | [mathin] t_{wf},\ f_{uw} [mathin] | 10 mm / 490 MPa |
| Placa lateral web | Símbolo | Valor |
|---|---|---|
| Placa lateral web | PL 10 x 120 x 325, AS / NZS 3678 Gr.300 | |
| Rendimiento de la placa / resistencia a la tracción | [mathin] f_{yp},\ f_{up} [mathin] | 310 MPa / 430 MPa |
| Pernos | 4 x M20 8.8/S in one column, 75 mm de paso | |
| Edge distances on plate / on beam web | [mathin] l_{ev\_wp},\ l_{eh\_wp},\ l_{eh\_w} [mathin] | 50 mm / 50 mm / 50 mm |
| Beam end clearance / first bolt column | [mathin] clr,\ l [mathin] | 20 mm / 70 mm |
| Excentricidad del grupo de pernos | [mathin] e_{b} [mathin] | 70 mm |
| Soldar al ala de la columna | 10 mm filete ambos lados, E49XX, SP |
The axial load is entered as an envelope, 60 kN in tension and 90 kN in compression. The two are separate cases, so the tension checks use the tension and the compression checks use the compression, and neither relieves the other.
Paso 1: Limitaciones detalladas de la placa de brida (AS 4100 Cláusula 9.5)
The bolt layout on the flange plate and the beam flange has to be buildable and match the assumptions behind the capacity equations. El tono mínimo es [mathin] 2.5\, d_{f} = 2.5 \times 20\ \text{mm} = 50\ \text{mm} [mathin] (Cláusula 9.5.1), and the minimum edge distance for an M20 bolt is 35 mm, [mathin] 1.75\, d_{f} [mathin] de la tabla 9.5.2. The minimum fillet weld for the 25 mm plate on the 25 mm column flange is 6 mm (Tabla 9.6.3.2).
| Límite de detalles | Límite (mm) | Actual (mm) | DCR | Resultado |
|---|---|---|---|---|
| Paso mínimo de fila de pernos en la placa de brida | 50.000 | 75.000 | 0.667 | PASAR |
| Paso máximo de fila de pernos en la placa de brida | 158.000 | 75.000 | 0.475 | PASAR |
| Paso mínimo de columna empernada en placa de brida | 50.000 | 110.000 | 0.455 | PASAR |
| Paso máximo de columna empernada en placa de brida | 200.000 | 110.000 | 0.550 | PASAR |
| Minimum bolt gauge on beam flange | 71.900 | 110.000 | 0.654 | PASAR |
| Distancia mínima al borde vertical en la placa de brida | 35.000 | 50.000 | 0.700 | PASAR |
| Distancia mínima al borde vertical en el ala de la viga | 35.000 | 40.000 | 0.875 | PASAR |
| Distancia mínima al borde horizontal en la placa de brida | 35.000 | 50.000 | 0.700 | PASAR |
| Distancia mínima al borde horizontal en el ala de la viga | 35.000 | 50.000 | 0.700 | PASAR |
| Distancia máxima al borde | 150.000 | 50.000 | 0.333 | PASAR |
| Minimum fillet weld size at flange plate to column flange | 6.000 | 10.000 | 0.600 | PASAR |
Para un límite mínimo, la relación es límite sobre real, y para un máximo es un límite real por encima. The governing row is the end distance on the beam flange, from the last bolt row to the end of the beam:
[math] DCR = \frac{35\ \text{mm}}{40\ \text{mm}} = 0.875 [math]
DCR = 0.875 ≤ 1.0, OK
Paso 2: Grupo de pernos en corte (AS 4100 Cláusulas 9.1.4, 9.2.2.1, 9.3.1)
Momento de diseño y fuerzas en el ala.
La conexión es rígida., entonces cláusula 9.1.4 sets the design moment at not less than half the design section moment capacity of the beam:
[math] M^{*} = \max\left( M^{*}_{x},\ 0.5\, \phi\, f_{yb}\, S_{x} \right) = \max\left( 70\ \text{kNm},\ 0.5 \times 0.9 \times (300\ \text{MPa}) \times (1.66 \times 10^{6}\ \text{mm}^{3}) \right) = 224.1\ \text{kNm} [math]
El 70 kNm from the analysis is below the minimum, asi que 224.1 kNm is used for every flange check. The moment is split into a flange force pair over the distance between the flange centres, and half the axial load is added to each flange:
[math] N^{*}_{f} = \frac{M^{*}}{d_{bm} – t_{fb}} + \frac{\max\left( N^{*}_{t},\ N^{*}_{c} \right)}{2} = \frac{224.1\ \text{kNm}}{457\ \text{mm} – 14.5\ \text{mm}} + \frac{90\ \text{kN}}{2} = 551.44\ \text{kN} [math]
With the envelope taken case by case, the force in the tension flange is [mathin] N^{*}_{ft} = 536.44\ \text{kN} [mathin] (con la 60 kN tension) and the force in the compression flange is [mathin] N^{*}_{fc} = 551.44\ \text{kN} [mathin] (con la 90 kN compression). The bolts, welds and block shear take the larger force, 551.44 kN.
Bolt capacity
The bolted length along the force is [mathin] l_{j} = (n_{p} – 1)\, s_{p} = 3 \times 75\ \text{mm} = 225\ \text{mm} [mathin], con menos de 300 mm, so the lap connection factor [mathin] k_{r} = 1 [mathin] (Cláusula 9.2.2.1). Las roscas están en el plano de corte único., entonces se utiliza el área central:
[math] \phi V_{f} = \phi\, 0.62\, f_{uf}\, k_{rd}\, k_{r}\, \left( n_{n} A_{c} + n_{x} A_{o} \right) [math]
[math] \phi V_{f} = (0.8) \times 0.62 \times (830\ \text{MPa}) \times (1) \times (1) \times \left( (1)(225\ \text{mm}^{2}) + (0)(314.16\ \text{mm}^{2}) \right) = 92.628\ \text{kN} [math]
The flange force is concentric with the bolt group, so all eight bolts share it (Cláusula 9.3.1):
[math] \phi V_{df} = n_{b}\, \phi V_{f} = 8 \times (92.628\ \text{kN}) = 741.02\ \text{kN} [math]
[math] N^{*}_{f} = 551.44\ \text{kN} \le \phi V_{df} = 741.02\ \text{kN} [math]
DCR = 551.44 kN / 741.02 kN = 0.744 ≤ 1.0, OK
Paso 3: Bolt group in bearing on the flange plate and the beam flange (AS 4100 Cláusula 9.2.2.4)
Each bolt bears on the flange plate and on the beam flange. The end bolts are limited by the distance to the end of the ply, and the inner bolts by the distance to the next hole. Para la placa de brida, con [mathin] d_{h} = 22\ \text{mm} [mathin]:
[math] a_{e1} = l_{eh\_fp} – 0.5\, d_{h} + 0.5\, d_{f} = (50\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 49\ \text{mm} [math]
[math] a_{e2} = s_{p} – d_{h} + 0.5\, d_{f} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]
The bearing capacity of a ply, con un factor de capacidad de 0.9:
[math] \phi V_{b} = \phi \min\left( 3.2\, d_{f}\, t_{p}\, f_{up},\ a_{e}\, t_{p}\, f_{up} \right) [math]
Para el 25 mm plate this gives 474.07 kN at each end bolt and 609.52 kN at each inner bolt. Each bolt column has one end bolt and three inner bolts:
[math] \phi V_{b,pl} = 2 \left[ 474.07\ \text{kN} + 3 \times (609.52\ \text{kN}) \right] = 4605.3\ \text{kN} [math]
El 14.5 brida de viga mm, con su 440 Resistencia a la tracción MPa, da 281.36 kN at each end bolt and 361.75 kN at each inner bolt:
[math] \phi V_{b,beam} = 2 \left[ 281.36\ \text{kN} + 3 \times (361.75\ \text{kN}) \right] = 2733.2\ \text{kN} [math]
[math] \phi V_{b} = \min\left( 4605.3\ \text{kN},\ 2733.2\ \text{kN} \right) = 2733.2\ \text{kN} [math]
DCR = 551.44 kN / 2733.2 kN = 0.202 ≤ 1.0, OK
Paso 4: Weld of the flange plate to the column (AS 4100 Cláusula 9.6.3.10)
The flange force passes from the plate into the column flange through the fillet welds across the plate width. La soldadura es de Propósito Estructural (SP), entonces el factor de capacidad es 0.8 de la tabla 3.4:
[math] \phi v_{w} = \phi\, 0.6\, f_{uw}\, \frac{\sqrt{2}}{2}\, t_{wf}\, k_{r} = (0.8) \times 0.6 \times (490\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (10\ \text{mm}) \times (1) = 1.6631\ \text{kN/mm} [math]
The weld length is the plate width, not more than the column flange width: [mathin] l_{w} = \min\left( b_{p},\ b_{fs} \right) = \min\left( 210\ \text{mm},\ 311\ \text{mm} \right) = 210\ \text{mm} [mathin]. The plate is welded on both faces:
[math] \phi N_{w} = 2\, l_{w}\, \phi v_{w} = 2 \times (210\ \text{mm}) \times (1.6631\ \text{kN/mm}) = 698.51\ \text{kN} [math]
[math] N^{*}_{f} = 551.44\ \text{kN} \le \phi N_{w} = 698.51\ \text{kN} [math]
DCR = 551.44 kN / 698.51 kN = 0.789 ≤ 1.0, OK
Este es el control de fuerza gobernante.. The weld length is set by the plate width, so a larger fillet or a wider plate is the way to add capacity here.
Paso 5: Placa de brida en corte en bloque (AS 4100 Cláusula 9.1.9)
Un bloque de la placa de brida puede romperse alrededor de los tornillos.: shear along the bolt lines plus tension across them. Three patterns are checked. The capacity factor is 0.75 and the tension stress is uniform, asi que [mathin] k_{bs} = 1 [mathin]:
[math] \phi R_{bs} = \phi \min\left( 0.6\, f_{up}\, A_{nv} + k_{bs}\, f_{up}\, A_{nt},\ 0.6\, f_{yp}\, A_{gv} + k_{bs}\, f_{up}\, A_{nt} \right) [math]
Patrones 1 y 2 shear along both bolt columns:
[math] A_{gv} = 2 \left[ l_{eh} + (n_{p} – 1)\, s_{p} \right] t_{p} = 13750\ \text{mm}^{2}, \qquad A_{nv} = 2 \left[ l_{eh} + (n_{p} – 1)\, s_{p} – (n_{p} – 0.5)\, d_{h} \right] t_{p} = 9900\ \text{mm}^{2} [math]
Patrón 1 tears across between the bolt columns, [mathin] A_{nt} = \left[ s_{g} – (n_{g} – 1)\, d_{h} \right] t_{p} = 2200\ \text{mm}^{2} [mathin], donación 2442 kN. Patrón 2 tears out to both side edges, [mathin] A_{nt} = (2\, l_{ev} – d_{h})\, t_{p} = 1950\ \text{mm}^{2} [mathin], donación 2361.4 kN. Patrón 3 is an L-shaped block along one bolt column and out to one side edge:
[math] A_{nt} = \left[ l_{ev} + (n_{g} – 1)\, s_{g} – (n_{g} – 0.5)\, d_{h} \right] t_{p} = 3175\ \text{mm}^{2}, \qquad A_{gv} = 6875\ \text{mm}^{2}, \qquad A_{nv} = 4950\ \text{mm}^{2} [math]
[math] \phi R_{bs} = \min\left( 2442\ \text{kN},\ 2361.4\ \text{kN},\ 1890.2\ \text{kN} \right) = 1890.2\ \text{kN} [math]
DCR = 551.44 kN / 1890.2 kN = 0.292 ≤ 1.0, OK
Paso 6: Ala de viga en corte en bloque (AS 4100 Cláusula 9.1.9)
On the beam flange, the block tears out along both bolt columns to the end of the beam and across to the two flange edges:
[math] A_{nt} = (2\, l_{ev\_f} – d_{h})\, t_{fb} = 841\ \text{mm}^{2}, \qquad A_{gv} = 2 \left[ 50\ \text{mm} + 3 \times 75\ \text{mm} \right] \times 14.5\ \text{mm} = 7975\ \text{mm}^{2}, \qquad A_{nv} = 5742\ \text{mm}^{2} [math]
[math] \phi R_{bs} = 1354.2\ \text{kN} [math]
DCR = 551.44 kN / 1354.2 kN = 0.407 ≤ 1.0, OK
Paso 7: Placa de brida en tensión (AS 4100 Cláusulas 9.1.10, 7.2, 7.3)
The tension flange plate carries the tension flange force. Its design section capacity is the lesser of yield on the gross area and fracture on the net area across a bolt row:
[math] A_{g} = b_{p}\, t_{p} = 5250\ \text{mm}^{2}, \qquad A_{n} = (b_{p} – n_{g}\, d_{h})\, t_{p} = 4150\ \text{mm}^{2} [math]
[math] \phi N_{t} = \phi \min\left( A_{g}\, f_{y},\ 0.85\, k_{t}\, A_{n}\, f_{u} \right) = 1323\ \text{kN} [math]
DCR = 536.44 kN / 1323 kN = 0.405 ≤ 1.0, OK
Paso 8: Placa de brida en compresión (AS 4100 Cláusulas 6.2.1, 6.2.2)
The compression flange plate carries the compression flange force. The bolt holes are filled by the bolts, so no reduction is made for them:
[math] \phi N_{s} = \phi\, k_{f}\, A_{g}\, f_{y} = 1323\ \text{kN} [math]
DCR = 551.44 kN / 1323 kN = 0.417 ≤ 1.0, OK
Paso 9: Ala de viga en tensión (AS 4100 Cláusulas 7.2, 7.3)
The beam flange itself carries the tension flange force into the bolts. With two holes across the flange:
[math] A_{g} = 2755\ \text{mm}^{2}, \qquad A_{n} = 2117\ \text{mm}^{2}, \qquad \phi N_{t} = 712.58\ \text{kN} [math]
DCR = 536.44 kN / 712.58 kN = 0.753 ≤ 1.0, OK
This is the second-highest strength ratio. The beam flange is thinner than the flange plate and loses two 22 mm holes from its 190 mm width.
Paso 10: Capacidad de momento de la sección de la viga en los agujeros del ala (AS 4100 Cláusulas 5.2.6, 5.2, 8.3.2)
The bolt holes in the beam flanges reduce the beam section at the bolts. Cláusula 5.2.6 allows the holes to be ignored only when they remove a small enough part of the flange. Here they do not:
[math] \Delta A_{f} = \frac{100\, n_{g}\, d_{h}}{b_{fb}} = 23.158 > \Delta A_{lim} = 19.786 [math]
Entonces los módulos de sección se reducen por la relación entre el área neta y el área bruta.. The net area deducts the flange holes:
[math] A_{n} = A – 2\, n_{g}\, d_{h}\, t_{fb} = 8244\ \text{mm}^{2} [math]
The section is compact under Clause 5.2.2 ([mathin] \lambda_{ef} = 6.8333 [mathin], [mathin] \lambda_{ew} = 51.522 [mathin]), so the effective section modulus is the reduced plastic modulus, limitado a 1.5 times the reduced elastic modulus:
[math] S_{n} = \frac{A_{n}}{A} S_{x} = 1.4375 \times 10^{6}\ \text{mm}^{3}, \qquad Z_{n} = \frac{A_{n}}{A} Z_{x} = 1.2479 \times 10^{6}\ \text{mm}^{3} [math]
[math] Z_{e} = \min\left( S_{n},\ 1.5\, Z_{n} \right) = 1.4375 \times 10^{6}\ \text{mm}^{3}, \qquad \phi M_{s} = \phi\, f_{y}\, Z_{e} = 388.13\ \text{kNm} [math]
The axial load reduces the moment capacity (Cláusula 8.3.2). In tension, the net area also deducts the holes of the nearest web bolt column, [mathin] A_{nw} = 7443.2\ \text{mm}^{2} [mathin], donación [mathin] \phi N_{t} = 2505.4\ \text{kN} [mathin], and the reduced capacity stays at 388.13 kNm. In compression, the effective area for local buckling is [mathin] A_{e} = 9027\ \text{mm}^{2} [mathin], asi que [mathin] k_{f} = 0.94821 [mathin] y [mathin] \phi N_{s} = 2437.3\ \text{kN} [mathin]. El 90 kN compression governs:
[math] \phi M_{rx} = \phi M_{s} \left( 1 – \frac{N^{*}_{c}}{\phi N_{s}} \right) = (388.13\ \text{kNm}) \times \left( 1 – \frac{90\ \text{kN}}{2437.3\ \text{kN}} \right) = 373.79\ \text{kNm} [math]
[math] M^{*} = 224.1\ \text{kNm} \le \phi M_{rx} = 373.79\ \text{kNm} [math]
DCR = 224.1 kNm / 373.79 kNm = 0.600 ≤ 1.0, OK
Paso 11: Supporting member at the flange plate (AS 4100 Cláusulas 5.11, 5.13)
Each flange plate delivers its force to one side of the column flange, so the column flange and web are checked locally. The flange plate is taken as at least [mathin] 10\, t_{fs} [mathin] from the column end, so no capacity is halved. The stiff bearing length is the plate thickness plus a weld leg each side, dispersed 1:1 a través de las soldaduras (Cláusula 5.13.1): [mathin] b_{s} = t_{p} + 2\, t_{wf} = 25\ \text{mm} + 2 \times 10\ \text{mm} = 45\ \text{mm} [mathin].
Column flange in local bending, at the tension flange plate:
[math] \phi R_{fb} = \phi\, 6.25\, t_{fs}^{2}\, f_{ys} = 984.38\ \text{kN} [math]
Column web in local yielding, at the tension flange plate:
[math] \phi R_{wy} = \phi\, f_{ys}\, t_{ws} \left[ 5 (t_{fs} + r_{s}) + b_{s} \right] = 999\ \text{kN} [math]
Column web in bearing yield, at the compression flange plate (Cláusula 5.13.3), with the bearing width dispersed through the column flange on both sides, [mathin] b_{bf} = b_{s} + 5\, t_{fs} = 170\ \text{mm} [mathin]:
[math] \phi R_{by} = \phi\, 1.25\, b_{bf}\, t_{ws}\, f_{ys} = 840.74\ \text{kN} [math]
Column web in crippling, con [mathin] \phi = 0.75 [mathin]:
[math] \phi R_{wc} = \phi\, 0.8\, t_{ws}^{2} \left[ 1 + 3 \frac{b_{s}}{d_{sup}} \left( \frac{t_{ws}}{t_{fs}} \right)^{1.5} \right] \sqrt{\frac{E\, f_{ys}\, t_{fs}}{t_{ws}}} = 1683.5\ \text{kN} [math]
Column web in bearing buckling (Cláusulas 5.13.4 y 6.3.3). The web is a compression member over its clear depth [mathin] d_{1} = 277\ \text{mm} [mathin], with a bearing width of [mathin] b_{b} = 447\ \text{mm} [mathin] and an area of [mathin] A_{wb} = 7017.9\ \text{mm}^{2} [mathin]. Con [mathin] l_{e}/r = 2.5\, d_{1}/t_{ws} = 44.108 [mathin], [mathin] \lambda_{n} = 46.68 [mathin] y [mathin] \alpha_{b} = 0.5 [mathin], the slenderness reduction factor is [mathin] \alpha_{c} = 0.82729 [mathin]:
[math] \phi R_{bb} = \phi\, \alpha_{c}\, k_{f}\, A_{wb}\, f_{ys} = 1463.1\ \text{kN} [math]
Panel de alma de pilar en corte (Cláusulas 5.11.2 y 5.11.4). The panel is stocky, [mathin] d_{p}/t_{w} = 17.643 \le 77.483 [mathin], and its shear area is [mathin] A_{ws} = d_{sup}\, t_{ws} = 5133.9\ \text{mm}^{2} [mathin]:
[math] \phi V_{c} = \phi\, 0.6\, f_{ys}\, A_{ws} = (0.9) \times 0.6 \times (280\ \text{MPa}) \times (5133.9\ \text{mm}^{2}) = 776.25\ \text{kN} [math]
[math] \phi R_{n} = \min\left( 984.38,\ 999,\ 840.74,\ 1683.5,\ 1463.1,\ 776.25 \right)\ \text{kN} = 776.25\ \text{kN} [math]
DCR = 551.44 kN / 776.25 kN = 0.710 ≤ 1.0, OK
The panel shear governs the column. La conexión es unilateral., so the whole flange force goes into the panel as shear.
Paso 12: Web side plate detailing limitations (AS 4100 Cláusula 9.5)
The web side plate is checked as its own shear connection, Para el 80 kN shear. Its layout is one column of four M20 bolts at 75 mm de paso.
| Límite de detalles | Límite (mm) | Actual (mm) | DCR | Resultado |
|---|---|---|---|---|
| Minimum bolt row pitch on web side plate | 50.000 | 75.000 | 0.667 | PASAR |
| Maximum bolt row pitch on web side plate | 136.400 | 75.000 | 0.550 | PASAR |
| Minimum vertical edge distance on web side plate | 35.000 | 50.000 | 0.700 | PASAR |
| Minimum horizontal edge distance on web side plate | 35.000 | 50.000 | 0.700 | PASAR |
| Distancia mínima al borde horizontal en el alma de la viga | 35.000 | 50.000 | 0.700 | PASAR |
| Minimum web side plate depth | 228.500 | 325.000 | 0.703 | PASAR |
| Maximum web side plate depth | 405.200 | 325.000 | 0.802 | PASAR |
| Distancia mínima | 20.000 | 20.000 | 1.000 | PASAR |
| Distancia máxima al borde | 109.200 | 50.000 | 0.458 | PASAR |
La fila gobernante es la holgura entre el extremo de la viga y el ala de la columna., which was set at the 20 mm mínimo:
DCR = 20 mm / 20 milímetro = 1.000 ≤ 1.0, OK
Paso 13: Minimum weld size of the web side plate (AS 4100 Cláusula 9.6.3)
The weld of the web side plate to the column is sized to develop the plate, taken by the program as three quarters of the plate thickness:
[math] 0.75\, t_{i} = 0.75 \times (10\ \text{mm}) = 7.5\ \text{mm} \le t_{ww} = 10\ \text{mm} [math]
DCR = 7.5 mm / 10 milímetro = 0.750 ≤ 1.0, OK
Paso 14: Weld of the web side plate to the column (AS 4100 Cláusulas 9.1.4, 9.6.3.10)
The minimum design shear for the shear connection (Cláusula 9.1.4) is the lesser of 0.15 times the beam’s shear capacity, [mathin] 0.15 \times 673.71\ \text{kN} [mathin], y 40 kN, asi que 40 kN. El 80 El corte kN es mayor y se utiliza. The welds run the full 325 mm plate depth on both sides, with no eccentricity:
[math] \phi v_{w} = 1.6631\ \text{kN/mm}, \qquad \phi V_{w} = 2\, l_{w}\, \phi v_{w} = 2 \times (325\ \text{mm}) \times (1.6631\ \text{kN/mm}) = 1081\ \text{kN} [math]
DCR = 80 kN / 1081 kN = 0.074 ≤ 1.0, OK
Paso 15: Web side plate bolt group in shear (AS 4100 Cláusulas 9.2.2.1, 9.3.1)
The shear acts 70 mm desde la línea de pernos, so the bolt group is analysed by the instantaneous centre of rotation (ICOR) método. The design shear capacity of one bolt is the same as in Step 2, [mathin] \phi V_{f} = 92.628\ \text{kN} [mathin]. The instantaneous centre is at [mathin] x_{ic} = -85.734\ \text{mm} [mathin], [mathin] y_{ic} = 112.5\ \text{mm} [mathin] del perno 1, at the bottom of the bolt column:
| Tornillo | x (mm) | y (mm) | R (kN) | Rx (kN) | Ry (kN) |
|---|---|---|---|---|---|
| 1 | 0.00 | 0.00 | 90.91 | 72.31 | 55.11 |
| 2 | 0.00 | 75.00 | 87.12 | 34.91 | 79.81 |
| 3 | 0.00 | 150.00 | 87.12 | -34.91 | 79.81 |
| 4 | 0.00 | 225.00 | 90.91 | -72.31 | 55.11 |
[math] \phi V_{df} = \sqrt{ \left( \sum R_{x} \right)^{2} + \left( \sum R_{y} \right)^{2} } = \sqrt{ (0\ \text{kN})^{2} + (269.84\ \text{kN})^{2} } = 269.84\ \text{kN}, \qquad C = \frac{269.84\ \text{kN}}{92.628\ \text{kN}} = 2.9132 [math]
DCR = 80 kN / 269.84 kN = 0.296 ≤ 1.0, OK
Paso 16: Web side plate bolt group in bearing (AS 4100 Cláusula 9.2.2.4)
The least edge distance governs each ply. en el plato, [mathin] a_{e} = \min(49,\ 63,\ 49)\ \text{mm} = 49\ \text{mm} [mathin], and on the beam web, [mathin] a_{e} = \min(63,\ 49)\ \text{mm} = 49\ \text{mm} [mathin]:
[math] \phi V_{b,pl} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (10\ \text{mm}) \times (430\ \text{MPa}),\ (49\ \text{mm}) \times (10\ \text{mm}) \times (430\ \text{MPa}) \right) = 189.63\ \text{kN} [math]
[math] \phi V_{b,beam} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (9.1\ \text{mm}) \times (440\ \text{MPa}),\ (49\ \text{mm}) \times (9.1\ \text{mm}) \times (440\ \text{MPa}) \right) = 176.58\ \text{kN} [math]
[math] \phi V_{b} = \min\left( 189.63\ \text{kN},\ 176.58\ \text{kN} \right) \times (2.9132) = 514.4\ \text{kN} [math]
DCR = 80 kN / 514.4 kN = 0.156 ≤ 1.0, OK
Paso 17: Placa lateral del alma en corte (AS 4100 Cláusula 5.11.3)
[math] \phi V_{v} = \phi\, 0.5\, f_{yp}\, d_{i}\, t_{i} = (0.9) \times 0.5 \times (310\ \text{MPa}) \times (325\ \text{mm}) \times (10\ \text{mm}) = 453.38\ \text{kN} [math]
DCR = 80 kN / 453.38 kN = 0.176 ≤ 1.0, OK
Paso 18: Placa lateral del alma en plegado (AS 4100 Cláusula 5.2.1)
[math] \phi M_{s} = \phi\, \frac{f_{yp}\, t_{i}\, d_{i}^{2}}{4} = (0.9) \times \frac{(310\ \text{MPa}) \times (10\ \text{mm}) \times (325\ \text{mm})^{2}}{4} = 73.673\ \text{kNm} [math]
[math] \phi V_{n} = \frac{\phi M_{s}}{e_{b}} = \frac{73.673\ \text{kNm}}{70\ \text{mm}} = 1052.5\ \text{kN} [math]
DCR = 80 kN / 1052.5 kN = 0.076 ≤ 1.0, OK
Paso 19: Placa lateral del alma en corte en bloque (AS 4100 Cláusula 9.1.9)
An L-shaped block tears out along the bolt column and across to the free edge of the plate:
[math] A_{nt} = 390\ \text{mm}^{2}, \qquad A_{gv} = 2750\ \text{mm}^{2}, \qquad A_{nv} = 1980\ \text{mm}^{2} [math]
[math] \phi R_{bs} = (0.75) \times \min\left( 0.6 \times (430)(1980) + (1)(430)(390),\ 0.6 \times (310)(2750) + (1)(430)(390) \right) \times 10^{-3} = 508.9\ \text{kN} [math]
DCR = 80 kN / 508.9 kN = 0.157 ≤ 1.0, OK
Paso 20: Miembro apoyado en corte (AS 4100 Cláusula 5.11.2)
[math] \frac{d_{p}}{t_{w}} = 47.033 \le \frac{82}{\sqrt{f_{y} / 250}} = 74.855 [math]
[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (457\ \text{mm}) \times (9.1\ \text{mm}) = 673.71\ \text{kN} [math]
DCR = 80 kN / 673.71 kN = 0.119 ≤ 1.0, OK
Resumen de controles
| Verificación de diseño | Efecto de acción de diseño | Capacidad de diseño | DCR | Resultado |
|---|---|---|---|---|
| Conexión de placa de brida | ||||
| Limitaciones de detalles de conexión | 35 mm | 40 mm | 0.875 | PASAR |
| Grupo de pernos en corte | 551.441 kN | 741.024 kN | 0.744 | PASAR |
| Bolt group in bearing on flange plate and beam flange | 551.441 kN | 2733.19 kN | 0.202 | PASAR |
| Soldar al miembro de soporte | 551.441 kN | 698.508 kN | 0.789 | PASAR |
| Placa de brida en corte en bloque | 551.441 kN | 1890.19 kN | 0.292 | PASAR |
| Ala de viga en corte en bloque | 551.441 kN | 1354.15 kN | 0.407 | PASAR |
| Placa de brida en tensión | 536.441 kN | 1323 kN | 0.405 | PASAR |
| Placa de brida en compresión | 551.441 kN | 1323 kN | 0.417 | PASAR |
| Ala de viga en tensión | 536.441 kN | 712.582 kN | 0.753 | PASAR |
| Section moment capacity of beam at flange holes | 224.1 kNm | 373.794 kNm | 0.600 | PASAR |
| Miembro de apoyo (columna) | 551.441 kN | 776.246 kN | 0.710 | PASAR |
| Web side plate connection | ||||
| Limitaciones de detalles de conexión | 20 mm | 20 mm | 1.000 | PASAR |
| Tamaño mínimo de soldadura | 7.5 mm | 10 mm | 0.750 | PASAR |
| Soldar al miembro de soporte | 80 kN | 1081.02 kN | 0.074 | PASAR |
| Grupo de pernos en corte | 80 kN | 269.843 kN | 0.296 | PASAR |
| Grupo de tornillos en apoyo sobre placa y alma de viga | 80 kN | 514.4 kN | 0.156 | PASAR |
| Placa lateral del alma en corte | 80 kN | 453.375 kN | 0.176 | PASAR |
| Placa lateral del alma en plegado | 80 kN | 1052.48 kN | 0.076 | PASAR |
| Placa lateral del alma en corte en bloque | 80 kN | 508.905 kN | 0.157 | PASAR |
| Miembro apoyado en corte | 80 kN | 673.709 kN | 0.119 | PASAR |
La conexión pasa todos los controles.. The weld of the flange plate to the column governs the strength checks at 0.789, followed by the beam flange in tension at 0.753 and the bolt group in shear at 0.744. Every flange check uses the 224.1 kNm minimum design moment of Clause 9.1.4, no el 70 kNm from the analysis. The web side plate detailing ratio is 1.000 because the beam end clearance was set at its 20 mm mínimo, and that is not a strength check.
Auto Design is available for the flange plate moment connection in the AS 4100 módulo. Cambia los tornillos, plates and welds until every check passes, y mantiene sus miembros y acciones de diseño tal como se ingresaron. Ver el Diseño automático pagina del AS 4100 preferencias con las que funciona.
Qué cambiar si falla un cheque
- Límites de detallado: ajustar el tono, gauge or edge distances to the limits in Step 1. A short end distance on the beam flange can be fixed by moving the bolts along the plate.
- Bolts in shear or bearing: agregar una fila de tornillos, o use un perno más grande. If the beam flange governs bearing, increase its end distance or the pitch.
- Flange plate weld: aumentar el tamaño del filete, or widen the plate where the column flange allows.
- Block shear or plate tension and compression: use una placa más gruesa o más ancha, or add a bolt row to lengthen the shear planes.
- Beam flange in tension or beam section at the holes: usar un haz más pesado.
- Column checks: usar una columna más pesada.
- Placa lateral web: hacer la placa más profunda o más gruesa, o agregar pernos, as for any web side plate shear connection.
Preguntas frecuentes
Why is the connection designed for 224.1 kNm when the moment is 70 kNm?
AS 4100 Cláusula 9.1.4 sets a minimum design action for a rigid connection: the design moment is not taken less than half the design section moment capacity of the beam. Para 460 UB 74.6 in Grade 300 es decir 0.5 x 0.9 x 300 MPax 1.66 x 10⁶ mm³ = 224.1 kNm. El 70 kNm from the analysis is below it, so the minimum governs.
How are tension and compression handled when the axial load is an envelope?
El 60 kN tension and the 90 kN compression are taken as separate cases. The tension flange checks add half the tension, and the compression flange checks add half the compression, so neither relieves the other. The bolts, welds and block shear take the larger of the two flange forces, 551.44 kN.
Why are the beam section moduli reduced at the bolt holes?
Cláusula 5.2.6 lets the holes in a flange be ignored only when they remove less than a set part of the flange area. Dos 22 agujeros de mm en un 190 mm flange give 23.158 contra un límite de 19.786, so the section moduli are reduced by the ratio of the net area to the gross area.
Why does the column web panel shear govern the column checks?
The beam frames into one side of the column only, so the full flange force enters the column web panel as shear. El 310 UC 158 web is stocky, so the panel reaches shear yield at 776.25 kN, which is lower than the flange bending, fluencia del alma, bearing and crippling capacities at the plate.
Does the web side plate carry any of the moment?
No. The moment is carried by the flange plates as a force pair, and the web side plate is designed as a shear connection for the 80 kN shear, with its own Clause 9.1.4 minimum of 40 kN.
Why is the bearing capacity added up bolt by bolt?
The end bolts and the inner bolts have different tear-out distances. An end bolt tears out to the end of the ply, 49 mm here, and an inner bolt tears out to the next hole, 63 mm. Each bolt column has one end bolt and three inner bolts, so the group capacity is the sum of the two kinds, taken for the weaker ply.
Diseñe una conexión de momento de placa de brida de forma gratuita
Cada número en esta página proviene de una solución.. Elige como 4100:2020 y la conexión de momento de la placa de brida, entra en tu rayo, columna, placas, pernos y cargas, y mira cada una de estas comprobaciones en tu navegador. No hay nada que instalar.
El módulo SkyCiv Connection Design es el software de diseño de conexiones detrás de este ejemplo.. Le brinda el informe de cálculo completo con cada ecuación y sus números en ella., como los pasos anteriores, además de todas las capacidades de diseño y DCR, para AS 4100:2020 conexiones de corte, conexiones de momento y empalmes. El calculadora de pernos y calculadora de soldadura Cubra el grupo de tornillos y verifique las soldaduras por su cuenta..
Referencias
- AS 4100:2020, Estructuras de acero: Cláusulas 5.2, 5.2.6, 5.11.2, 5.11.3, 5.11.4, 5.13, 6.2, 6.3.3, 7.2, 7.3, 8.3.2, 9.1.4, 9.1.9, 9.1.10, 9.2.2.1, 9.2.2.4, 9.3.1, 9.5, 9.6.3.10; Tablas 3.4, 9.5.2 y 9.6.3.2.
- Diseño de conexiones de acero utilizando AS. 4100:2020
- Diseño automático en Diseño de conexión SkyCiv
Harold Munalem
Gerente de producto, Connection Design
10+ años en el diseño de conexiones de acero
LinkedIn
