Documentación SkyCiv

Su guía para el software SkyCiv: tutoriales, guías prácticas y artículos técnicos

Diseño de conexión axial y corte de red soldada directamente

When a directly welded web connection carries an axial force as well as the end shear, two things change in the design to AISC 360. The welds now see a resultant force at an angle to their axis, which is larger than the shear alone but also earns the directional strength increase of Eq. J2-5. And the axial force is delivered to the column flange as a concentrated force, so the column has to be checked for flange local bending, web local yielding and, en compresión, web local crippling.

This page works the same connection as the shear-only directly welded web example, a W18x50 beam web welded to the flange of a W14x90 column with 3/16 en soldaduras de filete E70XX 15.5 in long on both sides of the web, and adds an axial force of 132 kip in tension or compression to the 38 kip end shear (LRFD). El diseño es para AISC. 360-16 y el Manual AISC 15ª edición. Cada ecuación está escrita con sus números., en el mismo orden que la hoja de cálculo que SkyCiv Connection Design El módulo produce para esta conexión..

What the axial force adds to a directly welded web connection

A beam in a braced frame or a diaphragm chord often carries an axial force along with its end reaction, for example as a strut or collector. With a directly welded web, that force has no plate or bolts to pass through: it goes straight from the web into the two fillet welds and from them into the column flange.

The member sizes, weld and the checks of the minimum weld size and the beam web in shear are the same as in the shear-only example, and give the same results. This page focuses on the weld under combined load and on the two support checks the axial force adds. The other shear connection types are on the conexiones de corte página.

Elevación del alma directamente soldada: W18x50 web welded to a W14x90 flange, 3/16 in E70XX fillets, Vu = 38 kip, Tu = Con = 132kipp

Elevación de la conexión de ejemplo., con la 38 cizalla kip y el 132 kip tension or compression at the beam end.

Pestaña Conjunto de diseño de conexión SkyCiv: Directly Welded Web config for shear plus axial, Viga W18x50 a ala de columna W14x90

La misma conexión en SkyCiv Connection Design, con la configuración Web directamente soldada en la pestaña Ensamblaje.

Directly welded web shear and axial design: los pasos de un vistazo

  1. Verifique el tamaño mínimo de soldadura de filete.
  2. Check the welds for the resultant of the shear and the axial force.
  3. Comprobar el alma de la viga en corte.
  4. Check the column for the axial tension: flange local bending and web local yielding.
  5. Check the column for the axial compression: web local crippling and web local yielding.

Entradas de diseño para este ejemplo

El código de diseño es AISC. 360-16 LRFD. Las propiedades de la sección son del Manual AISC.. Los kdes de la columna, utilizado en rendimiento local web, es 1.31 in.

ArtículoSímboloValor
corte factorizado[mathin] V_{u} [mathin]38 kip
Tensión axial factorizada[mathin] T_{u} [mathin]132 kip
Compresión axial factorizada[mathin] C_{u} [mathin]132 kip
BeamW18x50, A992
Profundidad del haz / espesor de la red[mathin] d_{bm},\ t_{wb} [mathin]18 in / 0.355 in
ColumnaW14x90, A992
Profundidad de la columna / espesor de la red[mathin] d_{sup},\ t_{ws} [mathin]14 in / 0.44 in
Ancho del ala de la columna / grosor[mathin] b_{fs},\ t_{fs} [mathin]14.5 in / 0.71 in
columna kdes[mathin] k_{des} [mathin]1.31 in
Rendimiento de vigas y columnas / tensión de tracción[mathin] F_{y},\ F_{u} [mathin]50 ksi / 65 ksi
Módulo de elasticidad[mathin] E [mathin]29000 ksi
Soldarfilete E70XX, ambos lados de la web
Tamaño de soldadura / length on each side[mathin] W,\ L_{wv} [mathin]0.1875 in / 15.5 in

Paso 1: Tamaño mínimo de soldadura de filete (AISC 360-16 J2.2b, Tabla J2.4)

The axial force does not change this check. The thinner part joined is the 0.355 en el alma de la viga, so the Table J2.4 minimum is 3/16 in, and the weld is 3/16 in.

DCR = 0.1875 in / 0.1875 en = 1.000 ≤ 1.0, OK

Paso 2: Welds under the resultant of shear and axial force (AISC 360-16 J2.4)

The base metal limit and the effective length are the same as for shear alone, half the web thickness against the column flange, and twice the weld size off each end:

[math] D_{max} = \frac{\min\left( t_{fs} F_{us},\ \frac{t_{wb}}{2} F_{ub} \right)}{3.09\ \text{kip/in}} = \frac{\min\left( (0.71\ \text{in})(65\ \text{ksi}),\ (0.1775\ \text{in})(65\ \text{ksi}) \right)}{3.09\ \text{kip/in}} = 3.7338 [math]

[math] L_{w} = 2\left[ L_{wv} – 2W \right] = 2 \times \left[ 15.5\ \text{in} – 2 \times 0.1875\ \text{in} \right] = 30.25\ \text{in} [math]

What changes is the load. The welds now carry the vertical shear along their axis and the axial force across it. The demand is the resultant of the two, at an angle to the weld axis:

[math] R_{u} = \sqrt{V_{u}^{2} + T_{u}^{2}} = \sqrt{(38\ \text{kip})^{2} + (132\ \text{kip})^{2}} = 137.36\ \text{kip} [math]

[math] \theta_{u} = \tan^{-1}\left( \frac{T_{u}}{V_{u}} \right) = \tan^{-1}\left( \frac{132}{38} \right) = 73.94^{\circ} [math]

A fillet weld loaded across its axis is stronger than one loaded along it, y la Ec. J2-5 rewards that with the directional term:

[math] \phi R_{n} = \phi\, 0.6\, F_{EXX} \frac{\sqrt{2}}{2} \min\left( W,\ \frac{D_{max}}{16} \right) \left[ 1 + 0.5 \left( \sin\theta_{u} \right)^{1.5} \right] L_{w} [math]

[math] \phi R_{n} = (0.75) \times 0.6 \times (70\ \text{ksi}) \times \frac{\sqrt{2}}{2} \times \min\left( 0.1875\ \text{in},\ \frac{3.7338}{16} \right) \times \left[ 1 + 0.5 \left( \sin 73.94^{\circ} \right)^{1.5} \right] \times (30.25\ \text{in}) = 185.84\ \text{kip} [math]

DCR = 137.36 kip / 185.84 salto = 0.739 < 1.0, OK

Este es el cheque gobernante.. The same welds are good for 126.33 kip under shear alone, so the load angle adds about 47% to their strength. The demand grows faster, aunque, de 38 kip to 137.36 kip, and the ratio rises from 0.301 a 0.739. The tension and compression cases have the same resultant, so one weld check covers both.

Paso 3: Alma de viga en corte (AISC 360-16 J4.2)

The beam web still carries only the 38 kip de cortante, over its full depth:

[math] \phi R_{n} = \phi\, 0.6\, F_{yb}\, d_{bm}\, t_{wb} = (1) \times 0.6 \times (50\ \text{ksi}) \times (18\ \text{in})(0.355\ \text{in}) = 191.7\ \text{kip} [math]

DCR = 38 kip / 191.7 salto = 0.198 < 1.0, OK

Paso 4: Columna bajo tensión axial. (AISC 360-16 J10.1, J10.2)

The axial tension pulls on the column flange along the line of the weld. AISC 360-16 J10 covers this as a concentrated force on the flange: flexión local de la brida (J10.1), where it applies, y la fluencia local del alma (J10.2). Web local paralizante (J10.3) is for compressive forces only.

Flexión local del ala

J10.1 does not require a flange local bending check when the length of loading measured across the member flange is less than 0.15 times the flange width:

[math] 0.15\, b_{f} = 0.15\, b_{fs} = 0.15 \times (14.5\ \text{in}) = 2.175\ \text{in} [math]

The load is delivered by the beam web, so the loaded length across the column flange is the web thickness, [mathin] t_{wb} = 0.355\ \text{in} [mathin]. That is less than 2.175 in, so flange local bending need not be checked.

Fluencia local del alma

The force spreads through the column flange into the web over the weld length plus [mathin] 5k [mathin] (Eq. J10-2):

[math] \phi R_{n} = \phi\, F_{ys}\, t_{ws} \left( 5 k_{des} + L_{wv} \right) = (1) \times (50\ \text{ksi}) \times (0.44\ \text{in}) \times \left( 5 \times 1.31\ \text{in} + 15.5\ \text{in} \right) = 485.1\ \text{kip} [math]

DCR = 132 kip / 485.1 salto = 0.272 < 1.0, OK

Paso 5: Columna bajo compresión axial. (AISC 360-16 J10.2, J10.3)

In compression the beam pushes on the column flange, so web local crippling joins web local yielding. Web local paralizante, Eq. J10-4, with the weld length as the bearing length:

[math] \phi R_{n,wlc} = \phi\, 0.8\, t_{ws}^{2} \left[ 1 + 3\left( \frac{L_{wv}}{d_{sup}} \right) \left( \frac{t_{ws}}{t_{fs}} \right)^{1.5} \right] \sqrt{\frac{E F_{ys} t_{fs}}{t_{ws}}}\, Q_{f} [math]

[math] \phi R_{n,wlc} = (0.75) \times 0.8 \times (0.44\ \text{in})^{2} \left[ 1 + 3\left( \frac{15.5}{14} \right) \left( \frac{0.44}{0.71} \right)^{1.5} \right] \sqrt{\frac{(29000\ \text{ksi})(50\ \text{ksi})(0.71\ \text{in})}{0.44\ \text{in}}} \times (1) = 465.59\ \text{kip} [math]

Web local yielding is the same as in tension, 485.1 kip. The lower of the two governs:

[math] \phi R_{n} = \min\left( 465.59\ \text{kip},\ 485.1\ \text{kip} \right) = 465.59\ \text{kip} [math]

DCR = 132 kip / 465.59 salto = 0.284 < 1.0, OK

Both column checks pass with room to spare, so this W14x90 needs no stiffeners or web doubler for these limit states.

Resumen de controles

Verificación de diseñoDemandaCapacidadDCRResultado
Tamaño mínimo de soldadura de filete0.1875 in0.1875 in1.000PASAR
Welds under shear and axial force137.36 kip185.84 kip0.739PASAR
Alma de viga en corte38 kip191.7 kip0.198PASAR
Columna bajo tensión axial132 kip485.1 kip0.272PASAR
Columna bajo compresión axial132 kip465.59 kip0.284PASAR

Every check in this directly welded web shear and axial connection design passes. El 1.000 La relación es el tamaño mínimo de soldadura de filete., que la 3/16 en soldadura cumple exactamente. De los controles de fuerza, las soldaduras gobiernan en 0.739 bajo la 137.36 kip resultant, contra 0.301 for the same welds under shear alone. The column checks for the axial force come next, with web local crippling in compression at 0.284.

Auto Design is available for the directly welded web connection with shear and axial load to a column flange. Cambia las variables de diseño de la conexión hasta que pase cada verificación., y mantiene a sus miembros y cargas como se ingresaron. Ver el Diseño automático página para las preferencias con las que funciona.

Qué cambiar si falla un cheque

  • Fuerza de soldadura: lengthen the welds, increase the weld size up to the base metal limit of the half web, o use un electrodo más fuerte. Past that limit a larger weld adds no strength.
  • Column web local yielding or crippling: a longer weld spreads the force over more of the column web and raises both strengths. Otherwise use a column with a thicker web, or add stiffeners or a web doubler.
  • Flexión local del ala: with a directly welded web it only applies if the loaded length across the flange reaches 0.15 times the flange width.
  • Minimum weld size or beam web shear: as for shear alone, meet the Table J2.4 minimum, o usar una viga más pesada.

Preguntas frecuentes

Why does the weld get stronger when the axial force is added?

The strength of a fillet weld depends on the direction of the load. Under pure shear the load runs along the weld, and the directional term of Eq. J2-5 es 1. Con 132 kip of axial force the resultant turns to 73.94 degrees from the weld axis, and the term rises toward its maximum of 1.5 for a load at 90 grados. Here it lifts the weld strength from 126.33 kip to 185.84 kip.

Why is only one weld check reported for both tension and compression?

The axial force is 132 dormir de cualquier manera, so the resultant on the welds is the same 137.36 kip at the same angle. The sign of the axial force matters for the column, which is why the support is checked separately for tension and compression.

Why is flange local bending not checked?

J10.1 only requires it when the force is spread across a meaningful width of the column flange. Here the force comes in through a 0.355 en el alma de la viga, which is much less than 0.15 veces el 14.5 en ancho de brida, 2.175 in, so J10.1 does not require the check.

Why is web local crippling checked only in compression?

Web local crippling is the buckling of the column web under a compressive force pushed through the flange. A tensile force pulls the web straight, so J10.3 applies to compressive forces only, while web local yielding applies to both.

¿Cómo cambiaría esto para AISC ASD en lugar de LRFD??

Los estados límite y las resistencias nominales son los mismos.. Con AISC ASD usted compara las fuerzas de nivel de servicio con la resistencia nominal dividida por un factor de seguridad: 0.75 for the welds and for web local crippling becomes a safety factor of 2.00, y 1.00 for web shear yielding and web local yielding becomes 1.50.

Diseñe una conexión web soldada directamente de forma gratuita

Cada número en esta página proviene de una solución.. Pick the directly welded web configuration with shear and axial load, entra en tu rayo, apoyo, weld and forces, y la calculadora gratuita ejecuta cada una de estas comprobaciones en su navegador sin necesidad de instalar nada.

El módulo SkyCiv Connection Design es el software de diseño de conexiones detrás de este ejemplo.. Le brinda el informe de cálculo completo con cada ecuación y sus números en ella., como los pasos anteriores, más todas las capacidades y DCR, según AISC 360-22 y AISC 360-16 (LRFD y TEA) y AS 4100:2020. El calculadora de soldadura cubre grupos de soldadura de filete por sí solos.

Referencias

  • AISC 360-16, Especificación para edificios de acero estructural: J2.2b (Tabla J2.4), J2.4 (Eq. J2-4, J2-5), J4.2 (Eq. J4-3), J10.1, J10.2 (Eq. J10-2), J10.3 (Eq. J10-4).
  • Manual de construcción en acero AISC, 15ª edición: Parte 9 (Eq. 9-2), Parte 10 (longitud de soldadura efectiva).
  • Diseño de conexiones de acero utilizando AISC. 360-16
  • Diseño automático en Diseño de conexión SkyCiv
Harold Munalem, Gerente de producto de SkyCiv Connection Design

Harold Munalem
Gerente de producto, Connection Design
10+ años en el diseño de conexiones de acero
LinkedIn

¿Cómo podemos ayudarle?

×

Actualizado noviembre 24, 2026

¿Sigue teniendo problemas? Contáctenos

Ir arriba