The design capacity of a fillet weld to AS 4100:2020 is a capacity per unit length, [mathin]\phi v_{w}[mathin], from Clause 9.6.3.10. It depends on the electrode strength, the throat of the weld, the weld category (SP veya GP) ve, for long welds in lap joints, a length reduction. Before that, Tablo 9.6.3.2 sets the smallest fillet that can be laid on the parts being joined.
This page explains each term and works it through with the welds of our flexible end plate design example: a 10 mm end plate welded to the web of a 460 Başlamak için bile dik bir öğrenme eğrisi gerektiren karmaşık UI sistemleriyle uğraşmadan ihtiyaçlarınıza uygun bir dizi bağlantı türü bulabilirsiniz. 82.1 ile 6 mm E49XX fillets on both sides, carrying 150 kN. Every number comes from the calculation report that SkyCiv Connection Design produces for that connection.

The design capacity of a fillet weld (Madde 9.6.3.10)
[math]\phi v_{w} = \phi \times 0.6 \times f_{uw} \times t_{t} \times k_{r}[math]
- [mathin]f_{uw}[mathin] is the nominal tensile strength of the weld metal: 490 MPa for E49XX electrodes, as used in the examples here.
- [mathin]t_{t}[mathin] is the design throat thickness. For an equal-leg fillet of leg size [mathin]t_{w}[mathin] the report uses [mathin]t_{t} = \frac{\sqrt{2}}{2} t_{w}[mathin].
- [mathin]\phi[mathin] is the capacity factor of Table 3.4: 0.8 for SP (structural purpose) welds and 0.6 for GP (general purpose) kaynaklar.
- [mathin]k_{r}[mathin] is the reduction factor for a welded lap connection.
The capacity of the weld group is then [mathin]\phi v_{w}[mathin] times the length of weld that carries the force.
Kaynak kategorisi: SP veya GP
The weld category is a choice in the weld input. SP welds are made and inspected to the higher quality level and take [mathin]\phi = 0.8[mathin]; GP welds take [mathin]\phi = 0.6[mathin], so the same weld is worth 25% less as GP. Most structural connections are specified SP.
Long welds in lap joints: k_r (Tablo 9.6.3.10(B))
A long fillet weld in a lap joint does not load evenly along its length: the ends take more than the middle. For these welds the program reduces the capacity with the weld length [mathin]l_{w}[mathin] in metres:
[math]k_{r} = 1.10 – 0.06\, l_{w}, \qquad 0.62 \le k_{r} \le 1.0[math]
Yani [mathin]k_{r}[mathin] stays at 1.0 up to about 1.7 m of weld and reaches the 0.62 floor at 8 m. The reduction is applied where a plate is lapped onto a member and welded along the direction of the force, such as the flange cover plates of a welded column splice. Beam shear connections, where the welds run across the end of the member, göstermek [mathin]k_{r,weld} = 1[mathin] in the report.
Minimum köşe kaynağı boyutu (Tablo 9.6.3.2)
The minimum size guards against a small weld cooling too fast on a thick part. The program takes the leg size from the thicker of the two parts joined, but never more than the thinner part:
| Thickness of the thicker part, t | Minimum leg size, [mathin]t_{w,min}[mathin] |
|---|---|
| kadar 7 mm | 3 mm |
| üzerinde 7 mm up to 10 mm | 4 mm |
| üzerinde 10 mm up to 15 mm | 5 mm |
| üzerinde 15 mm | 6 mm |
Çalışılan örnek: flexible end plate welds
Adım 1: Tasarım kesme (Madde 9.1.4)
A simple connection must be designed for at least the lesser of 0.15 kirişin tasarım kesme kapasitesinin çarpımı ve 40 kN. İçin 460 Başlamak için bile dik bir öğrenme eğrisi gerektiren karmaşık UI sistemleriyle uğraşmadan ihtiyaçlarınıza uygun bir dizi bağlantı türü bulabilirsiniz. 82.1, [mathin]\phi V_{vo} = 737.75\ \text{kN}[mathin]:
[math]V^{*}_{min} = \min\left( 0.15 \times 737.75,\ 40 \right) = 40\ \text{kN} \qquad V^{*} = \max\left( 150,\ 40 \right) = 150\ \text{kN}[math]
Adım 2: Minimum kaynak boyutu
Uç plakası 10 mm and the beam web 9.9 mm, so the thicker part is 10 mm and Table 9.6.3.2 asks for [mathin]t_{w,min} = 4\ \text{mm}[mathin]. bu 6 mm weld provided is larger:
DCR = 4 mm / 6 mm = 0.667 ≤ 1.0, TAMAM MI
Adım 3: Capacity per unit length
The welds run down both sides of the beam web, across the end of the beam, Bu yüzden [mathin]k_{r,weld} = 1[mathin]. With SP welds:
[math]\phi v_{w} = 0.8 \times 0.6 \times 490 \times \frac{\sqrt{2}}{2} \times 6 \times 1 = 0.99787\ \text{kN/mm}[math]
Adım 4: Weld group capacity
The welds are as long as the end plate is deep, [mathin]d_{i} = 325\ \text{mm}[mathin], Web'in her iki tarafında bir tane:
[math]\phi V_{w} = 2\, d_{i}\, \phi v_{w} = 2 \times 325 \times 0.99787 = 648.61\ \text{kN}[math]
DCR = 150 kN / 648.61 kN = 0.231 ≤ 1.0, TAMAM MI
Adım 5: The same welds as GP
Changing only the weld category to GP gives [mathin]\phi = 0.6[mathin]:
[math]\phi v_{w} = 0.6 \times 0.6 \times 490 \times \frac{\sqrt{2}}{2} \times 6 \times 1 = 0.7484\ \text{kN/mm} \qquad \phi V_{w} = 2 \times 325 \times 0.7484 = 486.46\ \text{kN}[math]
DCR = 150 kN / 486.46 kN = 0.308 ≤ 1.0, TAMAM MI
A second case: the web side plate weld
Şurada web tarafı plaka örneği a 10 mm plate is welded to a 25 mm sütun flanşı. Tablo 9.6.3.2 on its own asks for 6 mm. The program also asks for a leg of at least 0.75 çarpı levha kalınlığı, 7.5 mm, so that the weld is stronger than the plate and the plate yields first. bu 8 mm weld provided meets both:
[math]\phi v_{w} = 0.8 \times 0.6 \times 490 \times \frac{\sqrt{2}}{2} \times 8 \times 1 = 1.3305\ \text{kN/mm} \qquad \phi V_{w} = 2 \times 320 \times 1.3305 = 851.51\ \text{kN}[math]
DCR = 150 kN / 851.51 kN = 0.176 ≤ 1.0, TAMAM MI
Özet
| Kaynak | [mathin]\phi v_{w}[mathin] | [mathin]\phi V_{w}[mathin] | DCR |
|---|---|---|---|
| Uç plakası, 6 mm SP, 2 x 325 mm | 0.99787 kN/mm | 648.61 kN | 0.231 |
| Uç plakası, 6 mm GP, 2 x 325 mm | 0.7484 kN/mm | 486.46 kN | 0.308 |
| Web tarafı plakası, 8 mm SP, 2 x 320 mm | 1.3305 kN/mm | 851.51 kN | 0.176 |
What to change if a weld check fails
- Minimum size: increase the leg size to the Table 9.6.3.2 value for the thicker part, ve 0.75 times the plate thickness for a web side plate.
- Kapasite: increase the leg size, specify SP rather than GP, daha güçlü bir elektrot kullanın, or lengthen the weld with a deeper plate.
For web side plates, flexible end plates and the other AS connections it covers, Otomobil Tasarımı sizes the welds along with the plates and bolts.
Sıkça Sorulan Sorular
Why does the capacity use the throat and not the leg?
A fillet weld fails across its throat, the shortest path through the weld. For an equal-leg fillet the throat is the leg size times [mathin]\sqrt{2}/2[mathin], which is the factor in every [mathin]\phi v_{w}[mathin] line above.
Do I need a larger weld for a thicker part even if the load is small?
Evet. Tablo 9.6.3.2 is a minimum for weld quality, not strength. A small weld on a thick part cools too quickly and can crack, whatever the load.
Is a longer weld always stronger?
In a beam end connection, Evet: the capacity grows in proportion to length. In a lap joint where the weld runs along the force, the program applies the [mathin]k_{r}[mathin] reduction once the weld passes about 1.7 m, so the gain per metre drops.
Check your own welds for free
OLARAK Seç 4100:2020 and a welded connection, enter the electrode, weld size and category, and see each of these checks with its DCR. Yüklenecek hiçbir şey yok.
SkyCiv Bağlantı Tasarımı modülü size her denklem ve içindeki sayılarla birlikte tam hesaplama raporu sunar, AS için 4100:2020 kesme bağlantıları, Moment bağlantıları ve eklemeler. bu kaynak hesaplayıcı is a quick way to check a single weld group.
Referanslar
- GİBİ 4100:2020, Çelik Yapılar: Maddeler 9.1.4, 9.6.3.10; Tablolar 3.4, 9.6.3.2 ve 9.6.3.10(B).
- Flexible end plate connection design example to AS 4100
- Web side plate connection design example to AS 4100
- AS kullanarak çelik bağlantıların tasarımı 4100:2020
Harold Munalem
Ürün Müdürü, Bağlantı Tasarımı
10+ çelik bağlantı tasarımında yıllar
LinkedIn