SkyCiv Load Generator calculates roof snow loads for buildings in Spain to CTE DB SE-AE (Código Técnico de la Edificación, Documento Básico SE-AE). Enter a site address and it looks up the ground snow load \(s_{k}\), then applies the shape and exposure coefficients to give the snow load on the roof, \(q_{n}\), with a detailed calculation report. This page explains each input of the CTE DB SE-AE snow workflow and how the calculation uses it.
For CTE DB SE-AE, the Load Generator interface and the report are in Spanish. The labels on this page are the ones the software shows, with an English translation where it helps.
Free accounts can try the snow calculation with a limited number of solves and the basic roof profiles. With a Professional Account or the modulo Load Generator autonomo, you get unlimited solves, every roof profile and the full detailed snow load report.
Workflow Overview
The snow calculation follows the same top-to-bottom order as the rest of SkyCiv Load Generator:
- Selezionare CTE DB SE-AE (Spagna) as the design code. It covers wind and snow loads and uses metric units.
- Nel Dati del sito, enter the project address in Spain. The ground snow load is filled in from the map.
- Nel Dati della struttura, seleziona il Costruzione struttura, its roof profile and dimensions, then confirm the structure data.
- fai clic sulla scheda e ti verrà presentata una nuova barra multifunzione di strumenti come mostrato di seguito Carico di neve and set the snow parameters.
- Calculate the loads and review the snow results and the detailed report.
Dati del sito: Ground Snow Load for Spain
Inserisci l'indirizzo del progetto (or drop a pin on the map) in Spain. SkyCiv has digitized the snow map of CTE DB SE-AE, so the software reads the ground snow load for the site at the same time as the basic wind speed:
- Elevación del sitio (Elevazione del sito): the elevation of the ground above mean sea level, taken from the map. The report shows it as \(A\), and it also decides whether the overhang ice load and the flat roof simplification apply (vedere Risultati).
- Carga de Nieve en el Suelo (Carico di neve al suolo): the characteristic snow load on horizontal ground, \(s_{k}\), in kPa (Sezione 3.5.2). It is filled in automatically from the site location, and you can overwrite it. When you do, the report shows it as a user-defined value.
If the map has no ground snow load for the location, the map popup says so, and you can enter the value yourself or email [email protected] to request the location.
To see the snow zones, open the map data and select Spagna | CTE DB SE-AE under the snow maps.
The free calculator limits how many site lookups you can make per day. Professional Account and standalone module users can look up as many sites as they need.
Dati della struttura
The CTE DB SE-AE snow calculation is available for the Costruzione struttura (Estructura). Define the roof and the building dimensions, quindi fare clic Confirm Structure Data:
- Profilo del tetto (Profilo del tetto): Frontone/Duopitch, A padiglione, Monoslope/Monopitch, fai clic sulla scheda e ti verrà presentata una nuova barra multifunzione di strumenti come mostrato di seguito – Monoslope/Monopitch or Open – Inclinato/Duopitch. A padiglione, Monoslope and Open – Monoslope are PREMIUM options. The profile sets the roof shape in the model and in the snow load figure of the results.
- Lunghezza dell'edificio, d (Lunghezza dell'edificio) e Larghezza dell'edificio, b (Larghezza edificio): the plan dimensions of the building.
- Altezza dell'edificio, h (Building Height): the height from the ground to the top of the roof (the eave height for roof angles of 5° or less).
- Pendenza della copertura, θ (Angolo di inclinazione del tetto): the roof slope in degrees. It gives the shape coefficient \(\mu\). For an inverted duopitch roof, the interface asks for a negative value; the snow calculation uses its absolute value.
The building dimensions are used for the model and the wind calculation. For the snow load on the roof itself, the calculation uses the roof profile and the roof pitch angle.
Snow Load Parameters
Fai clic su Carico di neve to open the snow parameters. The snow load checkbox is checked by default once the site has a ground snow load.
Topografía (Coefficiente di esposizione)
The topography sets the exposure coefficient \(C_{e}\) di sezione 3.5.1(3):
| \(C_{e}\) | Luogo |
|---|---|
| 1.0 (predefinito) | Normal topography: areas where wind does not remove much snow from the building, because of the terrain, other buildings or trees. |
| 0.8 | Windswept topography: piatto, open areas exposed on all sides, with little or no shelter from the terrain, taller buildings or trees. |
| 1.2 | Sheltered topography: the building is much lower than the surrounding terrain, or is surrounded by tall trees or taller buildings. |
Each option in the dropdown shows its \(C_{e}\) valore: choose the option by that value.
Tipo de Nieve (Tipo di neve)
The type of snow sets the unit weight of the accumulated snow, \(\gamma\), di sezione 3.5.2(4). It is reported with the snow parameters:
| Opzione | \(\gamma\) |
|---|---|
| Para la recién caída (fresh snow, l'impostazione predefinita) | 1.2 kN/m³ |
| Para la prensada o empapada (compacted or soaked snow) | 2.0 kN/m³ |
| Para la mezclada con granizo (snow mixed with hail) | 4.0 kN/m³ |
Prendi in considerazione forme speciali del tetto?
For CTE DB SE-AE, the calculation covers the snow load on the roof profile you selected, so leave this on No.
Once the parameters are set, fai clic su Confirm Snow Parameters.
How the Snow Load Is Calculated
The shape coefficient \(\mu\) depends on the roof pitch angle \(\alpha\) (Sezione 3.5.3):
[math] \mu = 1.0 \quad \text{for} \quad 0^{\circ} \leq \alpha \leq 30^{\circ} [math]
[math] \mu = \frac{60^{\circ} – \alpha}{30^{\circ}} \quad \text{for} \quad 30^{\circ} < \alpha < 60^{\circ} [math]
[math] \mu = 0 \quad \text{for} \quad \alpha \geq 60^{\circ} [math]
The snow load per unit of horizontal projected area of the roof is then (Equazione 3.2):
[math] q_{n} = \mu \cdot s_{k} \cdot C_{e} [math]
Two checks depend on the site elevation \(A\):
- Overhang ice load: for sites above 1000 m, the report adds the line load on roof overhangs from ice formation, \(p_{n} = k \cdot \mu^{2} \cdot s_{k}\), con \(k = 3\,\text{m}\) (Sezione 3.5.1(4)). A o sotto 1000 m, the report states that it does not apply.
- Flat roofs: for a roof pitch of 0° on a site below 1000 m, the report also gives the simplified snow load of \(1.0\,\text{kN/m}^{2}\) that Section 3.5.1(1) allows for flat roofs of buildings.
Risultati
The snow results show the parameters used in the calculation (\(s_{k}\), \(C_{e}\), \(\gamma\) e \(\mu\)) and the snow load on the roof, \(q_{n}\), in kPa, with a figure of the load on the selected roof profile.
You can then apply the snow load to your structural model. Vedere Carico di neve integrato in SkyCiv S3D for how the Load Generator applies the roof snow load in S3D.
Detailed Snow Load Report
The detailed calculation report, in Spanish, shows every step of the CTE DB SE-AE snow calculation with its clause reference: the site elevation and ground snow load, the unit weight of snow, the exposure and shape coefficients, the roof snow load \(q_{n}\) with its figure, and the overhang and flat roof checks. It is available to Professional Account users and to those who purchased the standalone Load Generator module, and it is ready to attach to your design calculations.
For the ground snow load maps of the other design codes, vedere Carico di neve al suolo.