This page walks through the isolated footing design checks that SkyCiv Foundation performs to ACI 318-19: toprak yatağı, tek yönlü kesme, punching shear and flexure, with the equations used, plus the stability checks (yükselme, overturning and sliding). Flexure is described with the default Strip average method, ve Peak wood-armer method is summarized for comparison.

Temel, kolon ve duvar kuvvetlerini taşıyıcı zemine aktaran temel bir yapı sistemidir.. Mühendis, zemin özelliklerine ve bina yüklerine bağlı olarak sığ veya derin temel sistemini tercih edebilir.. SkyCiv Foundation designs isolated footings (yastık temelleri) to the American code ACI 318-19. To use it, seçin Amerikan Beton Enstitüsü as the Design Code and ACI 318 (2019) as the Version when you start a new file, then pick Tekil Temel.

SkyCiv Foundation Geometry tab with 3D model of an ACI 318 (2019) tekil temel, 1500×1500×500 mm, #5 donatı, dowels

The example shown on this page is the default pad footing (1500 × 1500 × 500 mm footing, 300 × 300 mm column, #5 bars at 150 mm each way) with a dead load of 400 kN and a live load of 250 kN on the column.

Design Settings for ACI 318-19

The methods used for the checks are set in Edit Design Settings (Details tab). ACI için 318-19, NS Moment Demand Calculation offers the Strip average method (varsayılan) ve Peak wood-armer method. The settings also hold the Perform One-Way Shear Check toggle and the Punching Shear Edge Factor (0.5 varsayılan olarak).

Design Settings dialog for ACI 318-19 in SkyCiv Foundation, with Moment Demand Calculation set to Strip average method.

Tekil Temel Tasarlamak İçin Adım Adım Kılavuz

Boyut Gereksinimleri

Yalıtılmış bir temelin boyutlarını belirlemek için, servis veya yüklenmemiş yükler, Ölü gibi (D), Canlı (L), Rüzgar (W), Sismik (E), vb. are combined using the load combinations of ACI 318-19 (Tablo 5.3.1). Whichever load combination governs is considered the design load, ve Denklemde gösterildiği gibi izin verilen toprak basıncıyla karşılaştırılır 1, as required by Kesit 13.3.1.1 ACI 318-19.

[math] q_{a} = \frac{P_{n}}{A} \quad \text{(Eq. 1)} [math]

qa = İzin verilen toprak basıncı
Pn = Faktörlenmemiş tasarım yükü
A = Temel alanı

Temel boyutları başlangıçta temel alanı çözülerek tahmin edilebilir. (Bir) Denklem kullanarak 1.

[math] A = \frac{P_{n}}{q_{a}} \quad \text{(Eq. 1a)} [math]

In SkyCiv Foundation, the footing dimensions are inputs (Geometry tab). The software checks them with the soil pressures from the finite element analysis, as described in Zemin Basıncı.

Tek Yönlü Kesme

Tek yönlü kayma sınırı durumu, kiriş kesme olarak da bilinir, recognizes that the footing may fail in shear similar to a wide beam along a critical section located at a distance “d” sütunun yüzünden (Figür 1). SkyCiv Foundation checks it in both directions (along x and along z). It can be turned off with Perform One-Way Shear Check in the design settings (varsayılan olarak açık).

One-way shear diagram in SkyCiv Foundation: footing plan with critical sections 417 mm from column, strip shear ±107.41 kN

Figür 1. One-way shear diagram (Sonuçlar, Diagrams button)

bu One-way Shear Demand veya \( V_{u} \) is taken from the strip shear diagram of the footing: the shear forces of the finite element analysis are summed across the full width of the footing, along a strip through the column, and read at the two critical sections. The larger absolute value of the ultimate load combinations is used, her yönde.

bu Tek Yönlü Kesme Kapasitesi veya \( \phi V_{c} \) is calculated with Equation 2 (Tablo 22.5.5.1(c), for members without shear reinforcement), with the full width of the footing perpendicular to the direction checked. The size effect factor \( \lambda_{s} \) is neglected for footings, as permitted by Kesit 13.2.6.2.

[math] \phi V_{c} = \phi_{\text{shear}} \times 8 \lambda \left( \rho_{w} \right)^{1/3} \sqrt{f’_{c}} \times b_{w} \times d \quad \text{(Eq. 2, Table 22.5.5.1(c), Imperial)} [math]

veya

[math] \phi V_{c} = \phi_{\text{shear}} \times 0.66 \lambda \left( \rho_{w} \right)^{1/3} \sqrt{f’_{c}} \times b_{w} \times d \quad \text{(Eq. 2, Table 22.5.5.1(c), Metric)} [math]

[math] \rho_{w} = \frac{n \times A_{b}}{b_{w} \times d} [math]

ϕkesme = Shear strength reduction factor, 0.75 (Tablo 21.2.1)
λ = Modification factor for lightweight concrete
rw = Ratio of the bottom bars in the direction checked
n, Birb = Number and area of these bars
f’c = Belirtilen beton dayanımı, (psi, MPa)
bw = Width of the footing perpendicular to the direction checked, (içinde, mm)
d = Effective depth of the bottom bars in the direction checked, (içinde, mm)

Kesme Talebi ve Kesme Kapasitesi, ACI tasarım gereksinimlerini karşılamak için aşağıdaki denklemi karşılamalıdır 318-19:

[math] V_{u} \leq \phi V_{c} \quad \text{(Eq. 3, Section 7.5.1.1(b))} [math]

SkyCiv Foundation, Denklem ile uyumlu 3, tek yönlü kesme fayda oranını hesaplar (Denklem 4) Kesme Kapasitesi yerine Kesme Talebini alarak. The larger ratio of the two directions is listed as Tek Yönlü Kesme in the Design Checks Summary.

[math] \text{Utility Ratio} = \frac{\text{Shear Demand}}{\text{Shear Capacity}} \quad \text{(Eq. 4)} [math]

Başlamak

Kendiniz denemek istersiniz?

SkyCiv'i bugün ücretsiz deneyin!

Ücretsiz Kayıt Olun

İki Yönlü Kesme (Delme Makası)

The two-way shear limit state, delme makası olarak da bilinir, has its critical section at a distance “d / 2” from the faces of the column, around the perimeter of the column (Figür 2). Its length is the critical perimeter \( b_{o} \).

Punching Shear diagram in SkyCiv Foundation Diagrams window: 1500 square footing, dashed critical perimeter at 0.5d around column

Figür 2. Critical perimeter of two-way shear (Sonuçlar, Diagrams button)

When a column face is closer to a footing edge than the Punching Shear Edge Factor kere d (design settings, 0.5 varsayılan olarak), the perimeter on that side extends to the footing edge and is not counted in \( b_{o} \). The column is then classified as an interior, edge or corner column, which sets \( \alpha_{s} \) = 40, 30 veya 20 (Kesit 22.6.5.3). If the column is close to two opposite edges, the punching shear check is skipped, as one-way shear governs.

bu Two-way Shear Demand is calculated at the critical perimeter with the mesh-based method, from the finite element analysis of the footing. The upward force from the soil pressure inside the critical perimeter, \( F_{q} \), is the sum of the forces of the mesh elements in that area, and it is subtracted from the factored column load. The maximum shear stress \( v_{u} \) on the critical perimeter also includes the unbalanced moments transferred by eccentric shear (ACI 421.1R-20):

[math] v_{u} = \frac{P_{u} – F_{q}}{b_{o} \times d} + \frac{\gamma_{v,x} \times M_{u,x} \times c_{x}}{J_{c,x}} – \frac{\gamma_{v,z} \times M_{u,z} \times c_{z}}{J_{c,z}} \quad \text{(Eq. 5)} [math]

Psen = Factored column load
cv = Fraction of the unbalanced moment transferred by eccentric shear
Msen = Unbalanced moment: column moment, plus column shear times the column height and footing thickness, minus the column load times the offset of the centroid of the critical section (edge and corner columns)
c, Jc = Distance to the point considered and polar moment of inertia of the critical section
d = Etkili derinlik, the average of the effective depths of the bottom bars in both directions

bu Kesme Kapasitesi is the punching shear stress \( \phi v_{c} \), governed by the smallest value of Equations 6, 7 ve 8 başına Kesit 22.6.5.2. Unlike ACI 318-14, NS 2019 edition includes the size effect factor \( \lambda_{s} \) (Kesit 22.5.5.1.3), which reduces the capacity of footings with an effective depth over 10 içinde (250 mm).

[math] \lambda_{s} = \min \left( 1, \sqrt{\frac{2}{1 + d/10}} \right) \quad \text{(Imperial)} \qquad \lambda_{s} = \min \left( 1, \sqrt{\frac{2}{1 + 0.004\,d}} \right) \quad \text{(Metric)} [math]

[math] v_{c} = 4 \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 6, Section 22.6.5.2(a), Imperial)} [math]

[math] v_{c} = \left( 2 + \frac{4}{\beta} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 7, Section 22.6.5.2(b), Imperial)} [math]

[math] v_{c} = \left( 2 + \frac{\alpha_{s} \times d}{b_{o}} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 8, Section 22.6.5.2(c), Imperial)} [math]

veya

[math] v_{c} = 0.33 \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 6, Section 22.6.5.2(a), Metric)} [math]

[math] v_{c} = \left( 0.17 + \frac{0.33}{\beta} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 7, Section 22.6.5.2(b), Metric)} [math]

[math] v_{c} = \left( 0.17 + \frac{0.083 \times \alpha_{s} \times d}{b_{o}} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 8, Section 22.6.5.2(c), Metric)} [math]

[math] \phi v_{c} = \phi_{\text{shear}} \times \min \left( v_{c,a}, v_{c,b}, v_{c,c} \right) [math]

Not: β sütunun uzun kenarının kısa kenarına oranıdır (1.0 for a round column, which is treated as an equivalent square), ve \( \alpha_{s} \) is given by Section 22.6.5.3. ϕkesme = 0.75 (Tablo 21.2.1).

λs = Size effect modification factor
λ = Hafif betonun aynı basınç dayanımına sahip normal betona göre azalan mekanik özelliklerini yansıtan modifikasyon faktörü
f’c = Belirtilen basınç beton dayanımı (psi, MPa)
d = Etkili derinlik, the average of the effective depths of the bottom bars in both directions, (içinde, mm)
bÖ = Critical perimeter (içinde, mm)

Kesme Talebi ve Kesme Kapasitesi, ACI tasarım gereksinimlerini karşılamak için aşağıdaki denklemi karşılamalıdır 318-19:

[math] v_{u} \leq \phi v_{c} \quad \text{(Eq. 9, Section 7.5.1.1(b))} [math]

SkyCiv Foundation, Denklem ile uyumlu 9, iki yönlü kesme fayda oranını hesaplar (Denklem 10) Kesme Kapasitesi yerine Kesme Talebini alarak, both as stresses. The result is listed as Delme Makası in the Design Checks Summary.

[math] \text{Utility Ratio} = \frac{\text{Shear Demand}}{\text{Shear Capacity}} \quad \text{(Eq. 10)} [math]

Başlamak

Kendiniz denemek istersiniz?

SkyCiv'i bugün ücretsiz deneyin!

Ücretsiz Kayıt Olun

Eğilme

Moment Demand with the Strip Average Method

bu Eğilme Talebi veya \( M_{u} \) comes from the finite element analysis of the footing. İle Strip average method (varsayılan Moment Demand Calculation), the footing is treated like a wide beam in each direction: the Wood-Armer moments of the plate elements are summed across the full width of the footing, along a strip through the column, which gives the total moment carried by the whole width at each section (Figür 3). This is done for the top and bottom layers, along x and along z, under the ultimate load combinations.

  • Bottom layer: \( M_{u} \) is the strip moment at the column faces, the larger of the two faces.
  • Top layer: \( M_{u} \) is the largest hogging (olumsuz) strip moment along the strip.

Moment diyagramı, bottom layer along X, in SkyCiv Foundation Diagrams window: strip moment is 121.50 kN-m at both column edges

Figür 3. Strip average moment diagram, bottom layer along X (Sonuçlar, Diagrams button)

The detailed report shows the same diagram for each layer and direction, with a table of the maximum moment, its coordinates and the governing load combination, followed by the utility ratio (Figür 4).

Design report: Bottom-X-direction moment demand, strip moment diagram peaking at 121.497 kN-m for U2a, oran 0.598, GEÇMEK

Figür 4. Moment demand and utility ratio in the design report (Ayrıntılı Raporu Görüntüle)

Peak Wood-Armer Method

İle Peak wood-armer method, \( M_{u} \) is instead the maximum Wood-Armer moment per unit width found anywhere over the footing, for the top and bottom layers in both directions, and the capacity is calculated per unit width (12 in or 1000 mm). Because it uses the peak moment, usually at the column, rather than the moment spread over the full width, it gives a more conservative design. It is described in the ACI ile Tekil Temel Tasarımı Adım Adım Çözümü 318-14, where it is the only method available.

Eğilme Kapasitesi

With the strip average method, NS Eğilme Kapasitesi veya \( \phi M_{n} \) is calculated for the full width of the footing, with all the bars of the layer across that width, Denklem kullanarak 11.

[math] \phi M_{n} = \phi_{\text{flexure}} \times A_{s} \times f_{y} \times \left( d – \frac{a}{2} \right) \quad \text{(Eq. 11)} [math]

[math] a = \frac{A_{s} \times f_{y}}{0.85 \times f’_{c} \times b} [math]

ϕeğilme = flexural strength reduction factor (Tablo 21.2.2)
Birs = area of the bars of the layer across the width of the footing (içinde2, mm2)
fY = reinforcement strength, (psi, MPa)
d = aşırı sıkıştırma elyafından uzunlamasına gerilim takviyesinin ağırlık merkezine olan mesafe (içinde, mm)
a = eşdeğer dikdörtgen gerilme bloğunun derinliği (içinde, mm)
b = width of the footing perpendicular to the bars (içinde, mm)

The strength reduction factor depends on the net tensile strain \( \varepsilon_{t} \), found from the neutral axis depth \( c = a/\beta_{1} \) (b1 Tablodan 22.2.2.4.3) and a concrete strain of 0.003. ACI 318-19 compares it with the yield strain of the reinforcement \( \varepsilon_{ty} = f_{y}/E_{s} \):

[math] \phi_{\text{flexure}} = 0.65 + 0.25 \times \frac{\varepsilon_{t} – \varepsilon_{ty}}{0.003} \quad \text{(Table 21.2.2)} [math]

with ϕ = 0.90 Ne zaman \( \varepsilon_{t} \geq \varepsilon_{ty} + 0.003 \) (tension-controlled) and ϕ = 0.65 Ne zaman \( \varepsilon_{t} \leq \varepsilon_{ty} \) (compression-controlled). The report shows a warning when the section is not tension-controlled. When top bars are provided and the tension steel ratio exceeds the balanced ratio, the section is checked as doubly reinforced.

The provided reinforcement is also compared to the minimum area of 0.0018 Birg (Kesit 8.6.1.1), in each direction and for each layer. Without top bars, the top face is checked as plain concrete (Kesit 14.5.2.1):

[math] \phi M_{n} = \phi \times 5 \lambda \sqrt{f’_{c}} \times S \quad \text{(Imperial)} \qquad \phi M_{n} = \phi \times 0.42 \lambda \sqrt{f’_{c}} \times S \quad \text{(Metric)} [math]

ϕ = 0.60 for plain concrete
S = section modulus of the full width of the footing (b × h2/6)

Moment Demand and Moment Capacity, ACI tasarım gereksinimlerini karşılamak için aşağıdaki denklemi karşılamalıdır 318-19:

[math] M_{u} \leq \phi M_{n} \quad \text{(Eq. 12, Section 7.5.1.1(a))} [math]

SkyCiv Foundation, Denklem ile uyumlu 12, bükülme fayda oranını hesaplar (Denklem 13) Eğilme Kapasitesi yerine Eğilme Talebi alarak. The Flexure ratio in the Design Checks Summary is the largest of the top, bottom and minimum reinforcement ratios. In the example, the bottom layer along X has a ratio of 121.5/203.01 = 0.598, and the Flexure ratio of 0.671 comes from the minimum reinforcement check.

[math] \text{Utility Ratio} = \frac{\text{Flexure Demand}}{\text{Flexure Capacity}} \quad \text{(Eq. 13)} [math]

Başlamak

Kendiniz denemek istersiniz?

SkyCiv'i bugün ücretsiz deneyin!

Ücretsiz Kayıt Olun

Ek Kontroller

Kodda belirtilmeyen diğer doğrulamalar, toprak basıncı kontrolleri dahil, yükselme, ve diğer stabilite kontrolleri de doğrulandı. The Design Checks Summary also lists Çelik Taban Plakası Tasarımı, Beton mesnedi kontrol eder (bearing at the column base), Yayılmış Temel Tasarım İş Akışı Süreci ve Detaylandırma. The development length checks are explained in the ACI 318 (2019) Kenetlenme Boyu Kontrol Kılavuzu.

Zemin Basıncı

Taban basıncının veya zemin ile temel arasındaki etkileşimin belirlenmesi öncelikle temel boyutlarına ve bunun sonucunda uygulanan yüklerin dışmerkezliğine bağlıdır.. Ortaya çıkan bu eksantrikliğin konumuna bağlı olarak, taban basıncı temel üzerinde tam veya kısmi basınç oluşmasına neden olabilir. Bu değerlendirme, alttaki toprağın temelden iletilen yüklerin tamamını taşıyıp taşıyamayacağını doğrulamamızı sağlar.. SkyCiv Foundation takes the soil pressures from the finite element analysis of the footing.

Soil Pressure contour from the FEA in SkyCiv Foundation, with the Design Checks Summary showing Soil Bearing at 0.619

Toprak basıncını manuel olarak hesaplamaya yönelik ayrıntılı bir kılavuz için, lütfen bu bağlantıya bakın: Dikdörtgen Beton Temel Altında Basınç Dağılımı

Fayda oranı maksimum toprak basıncı karşılaştırılarak değerlendirilir. (hizmet verilebilirlik durumu) ile İzin Verilen Brüt Zemin Taşıma Kapasitesi entered in the Soil tab. It is listed as Yayılmış Temel Tasarım İş Akışı Süreci in the Design Checks Summary.

[math] \text{Utility Ratio} = \frac{\text{Max. Soil Pressure}}{\text{Gross Allowable Soil Bearing Capacity}} \quad \text{(Eq. 14)} [math]

Yukarı çekme

Temele etki eden geçerli eksenel yükü kontrol eder, considering axial loads only. Kullanıcı yükü ve sütunun öz ağırlıkları dahil tüm dikey yükleri toplar, temel levhası, zemin, ve kaldırma kuvveti. Sütun yukarıya doğru bir kuvvetle karşılaşırsa, belirtilen öz ağırlıklar yukarı doğru kuvveti dengelemelidir; aksi takdirde, tasarım istikrarsızlık nedeniyle başarısızlık riski taşır. When no service load combination produces uplift, the check is not needed.

Devrilme

Overturning of the footing is checked by summing up all moments about the toe and the heel of the footing in each direction, including all the forces acting on it. All service load combinations are considered to find the governing overturning moment. The factor of safety (stabilising moment over overturning moment) is compared with the Devrilme factor of safety in the Analiz sonuçlarınızın solundaki sekmesi, yukarıda listelenen tüm tasarım kodlarının bir açılır listesini getirecektir. sekme (2.0 varsayılan olarak). If the applied loads produce no overturning moment, the check is not needed.

Kayma

To check for sliding in each direction, the sum of the horizontal resisting forces is divided by the horizontal force applied to the footing, taken from the governing service load combination.

  • Resisting forces:
    • Friction between the footing base and the soil (coefficient of friction times the axial force on the base; none under net uplift)
    • Pasif toprak basıncı
    • Cohesion of the soil
  • Kayma kuvveti:
    • The horizontal (kesme) load applied to the column

The resulting factor of safety is compared with the Kayma factor of safety in the Analiz sonuçlarınızın solundaki sekmesi, yukarıda listelenen tüm tasarım kodlarının bir açılır listesini getirecektir. sekme (1.5 varsayılan olarak). Temele herhangi bir yatay kuvvet etki etmiyorsa, kayma kontrolü gerekli değildir.

SkyCiv Foundation Design Modülü

SkyCiv'in Temel Tasarım Modülü Sonlu Elemanlar Analizi ile entegredir (ÇİRKİN), delivering more accurate soil pressure analysis and Wood-Armer moments for the flexural design checks.

Shear and moment diagrams are generated directly from the FEA results using the strip average method, Temel boyunca iç kuvvetlerin daha net bir resmini sağlamak. Open them with the Diagrams button of the Results tab, and pick the Durum, NS Diagram (Tek Yönlü Kesme, Punching Shear or Moment), NS Yük Kombinasyonu, NS ACI-Doğrulama-Kitaplar-Önizleme ve yön.

Modül gelişmiş temel konfigürasyonlarını destekler, hem izole edilmiş hem de birleştirilmiş temeller için herhangi bir yöndeki sütun ötelemeleri dahil. Yükler ve momentler herhangi bir yönde de uygulanabilir, Gerçek dünyadaki temel koşullarının doğru şekilde modellenmesine olanak tanır.

SkyCiv Kullanıcısı Değil? İçin kaydolun Ücretsiz 14 Günlük Deneme bir referans noktasından üye ekleme işlevi!

Jerome Carlo San Juan Ürün Geliştiricisi
Jerome Carlo San Juan
Ürün geliştirici
lisans (Sivil), Yüksek Lisans (Sivil)
LinkedIn

Referanslar

  1. Yapısal Beton için Bina Kodu Gereklilikleri (ACI 318-19) ve Yorum (ACI 318R-19). Amerikan Beton Enstitüsü, 2019.
  2. ACI Committee 421. Guide to Shear Reinforcement for Slabs (ACI 421.1R-20). Amerikan Beton Enstitüsü, 2020.

Nasıl yardımcı olabiliriz?

×

Güncellendi Kasım 24, 2026

Hâlâ takıldınız mı? Bize Ulaşın

Başa gitmek