Τεκμηρίωση SkyCiv

Ο οδηγός σας για το λογισμικό SkyCiv — σεμινάρια, οδηγοί και τεχνικά άρθρα

ASCE 7-22 Υπολογισμοί Σεισμικού Φορτίου

SkyCiv Load Generator calculates ASCE 7-22 seismic loads for buildings with the Equivalent Lateral Force (ELF) διαδικασία. It looks up the seismic design parameters for your site, then gives you the seismic base shear, the vertical distribution of forces per floor, the diaphragm forces and the design response spectrum. This page explains each input in the seismic workflow and how the calculation uses it.

Free accounts can try the workflow with limited solves. With a Professional Account or the αυτόνομη μονάδα γεννήτριας φορτίου, you get unlimited use of every feature, including the detailed seismic calculation report.

Workflow Overview

The workflow follows the same top-to-bottom order as the rest of the Γεννήτρια φορτίου SkyCiv:

  1. Επιλέγω ASCE 7-22 as the design code and the unit system (Αυτοκρατορικό ή Μετρικό).
  2. Σε Δεδομένα ιστότοπου, enter the location, the Risk Category and the Site Class.
  3. Σε Δεδομένα δομής, επίλεξε το Κτίριο structure and enter its dimensions.
  4. Ανοιξε Σεισμικό Φορτίο and define the seismic parameters.
  5. Κάντε κλικ Υπολογισμός φορτίων and review the results.

Για την ASCE 7-22, the seismic calculation is available for the Κτίριο δομή. For the ASCE 7-16 εκδοχή, which also covers solar panels and rooftop equipment, βλέπω ASCE 7-16 Υπολογισμοί Σεισμικού Φορτίου.

Δεδομένα ιστότοπου: Seismic Design Parameters

Εισαγάγετε τη διεύθυνση του έργου (or drop a pin on the map) και ρυθμίστε το Κατηγορία κινδύνου. Κάτω από For Seismic Load, επίλεξε το Κατηγορία τοποθεσίας from the ASCE 7-22 λίστα:

  • Default Site Conditions
  • ΕΝΑ – Hard rock
  • σι – Medium hard rock
  • Π.Χ – Soft rock
  • ντο – Very dense sand or hard clay
  • CD – Dense sand or very stiff clay
  • ρε – Medium dense sand or stiff clay
  • DE – Loose sand or medium stiff clay
  • μι – Very loose sand or soft clay

The Site Class follows Table 20.2-1 του ASCE 7-22. SkyCiv then fetches the seismic hazard values for the location and shows them under Σεισμικά δεδομένα USGS:

Παράμετρος Εννοια How it is used
\( S_{1} \) Mapped maximum considered earthquake (MCE) spectral response acceleration at a 1 s period Hazard input at long periods
\( T_{L} \) Μεταβατική περίοδος μεγάλης περιόδου Sets where the design response spectrum changes from constant velocity to constant displacement
\( S_{DS} \) Design spectral response acceleration at short periods Controls the plateau of the design spectrum and the short-period seismic response coefficient
\( S_{D1} \) Design spectral response acceleration at a 1 s period Controls the long-period branch of the spectrum
\( T_{0} = 0.2 S_{D1} / S_{DS} \) Start of the spectrum plateau Defines the shape of the design response spectrum

You can edit any of these values if your project uses site-specific results, for example from a site response analysis. All of them, together with the Site Class, must have a value before the seismic calculation can run.

Seismic Load Parameters for Buildings

Κάντε κλικ Σεισμικό Φορτίο to open the seismic parameters. The seismic checkbox beside the button is checked automatically when the site values are complete. These are the building inputs:

  • Structure System: the lateral system of the building (steel moment-resisting frames by default, concrete moment-resisting frames, steel eccentrically braced frames, steel buckling-restrained braced frames, or all other structural systems). It sets the coefficients \( C_{t} \) και \( x \) of Table 12.8-2, which are shown in the dropdown for the unit system you selected.
  • Θεμελιώδης Περίοδος της Δομής, Τ (ή \( T_{a} \)): when you pick a Structure System, SkyCiv fills this field with the approximate period \( T_{a} = C_{t} h_{n}^{x} \), using the roof mean height from Structure Data as \( h_{n} \). You can overwrite it with a period from a dynamic analysis, για παράδειγμα SkyCiv S3D Dynamic Frequency Analysis. A longer period lowers the base shear, so check any value you override.
  • Συντελεστής Τροποποίησης Απόκρισης, Ρ: η προεπιλογή είναι 3.5. Take the value for your seismic force-resisting system from Table 12.2-1 (or Tables 12.14-1, 15.4-1 και 15.4-2 where they apply). The base shear is inversely proportional to R.
  • Redundancy Factor, ρ: επιλέξτε 1.0 (Προκαθορισμένο) ή 1.3 according to Section 12.3.4. It is used in the diaphragm force calculation.
  • Βάρη δαπέδου: a table of Level, Elevation and Weight for each floor. Χρήση Add Floor Weights Data to add rows and Σαφή to empty the table. The total weight gives the seismic base shear, and each floor’s weight and height drive the vertical distribution of forces.

How the Parameters Work Together

In the Equivalent Lateral Force procedure, the Site Class and the hazard values \( S_{DS} \) και \( S_{D1} \) define the design response spectrum. The period \( T \) is read on that spectrum to get the seismic response coefficient \( C_{s} \), which is reduced by \( R \) and increased by the importance of the building (from the Risk Category). The seismic base shear is then:

[math] V = C_{s} W [math]

όπου \( W \) is the effective seismic weight from the Floor Weights table. The base shear is distributed over the height of the building in proportion to the weight and elevation of each floor, which gives the force at each level. The redundancy factor \( ρ \) is applied when the diaphragm forces are calculated.

Calculate Loads and Review the Results

Κάντε κλικ Υπολογισμός φορτίων at the upper right. Το Σεισμικό Φορτίο results tab shows:

  • Seismic Parameters: every input and derived value used in the calculation.
  • Κατακόρυφη Κατανομή Σεισμικών Δυνάμεων: the force at each floor and the base shear.
  • Diaphragm forces: the floor diaphragm design forces.
  • Φάσμα απόκρισης: the design response spectrum generated for your site.

Ξεκίνα

Θέλετε να το δοκιμάσετε μόνοι σας?

Δοκιμάστε το SkyCiv σήμερα δωρεάν!

Εγγραφείτε Δωρεάν

Detailed Seismic Calculation Report

Το Detailed Seismic Calculation Report is a Premium feature. It lists every equation, parameter and assumption used in the calculation, so you can check the result and attach it to your design documentation. It is available with a Professional Account or the standalone Load Generator module.

For wind loads on the same project, βλέπω ASCE 7-22 Υπολογισμοί φορτίου ανέμου.

Πώς μπορούμε να βοηθήσουμε?

×

Μεταβείτε στην κορυφή