Standalone Reinforced Concrete Beam and Column Design (AS 3600, IM 2, ACI 318)
This page explains how to design reinforced concrete beams and columns with the standalone version of SkyCiv RC Design, where you enter the design forces manually. It walks through each tab of the module (Einzelheiten, Faktoren und Einstellungen, Stäbe, RC-Layouts, Kräfte, Combinations and Results) für AS 3600, Eurocode 2 (IM 2) und ACI 318. To design the members of a SkyCiv Structural 3D model instead, sehen beam and column design in Structural 3D.
Einzelheiten
After you choose a design code, the module opens on the Einzelheiten Tab, unten gezeigt. The units are set automatically from the design code: metric for AS 3600 und EN 2, imperial for ACI 318.

On this tab, you can enter the project details:
- Projektname
- Projekt-ID
- Company name
- Designer
- Klient
- Any other notes you want to include
This information appears in the design report.
Faktoren und Einstellungen
Analysis Settings

Im Analysis Settings, you set the number of iterations the program uses to find the depth of the compression zone of the section. This depth is then used to calculate the ultimate flexural capacity of the section. The procedure is:
- Angenommen, die Tiefe der neutralen Achse, x (Anfangswert d, the effective depth).
- Calculate the concrete compression force and the steel tension and compression forces.
- Check the equilibrium of the force components.
- Repeat until the sum of the compression forces equals the tension forces.

The same iterative procedure is used to calculate the neutral axis depth at the serviceability limit state, where the compressed concrete has a triangular stress distribution. 40 iterations are generally enough. The ultimate flexural capacity is calculated as \(M_{\text{ult}} = F_{c} \cdot a_{c} + F_{cs} \cdot a_{cs} + F_{s} \cdot a_{s}\). The design report describes these calculations in detail.
For column members under combined axial force and bending, the module uses the N-M interaction curve. To build this curve, the program needs a number of intermediate points. There are three main points: maximale axiale Spannung, maximum axial compression and the balanced condition. Intermediate points are then added from the balanced condition to maximum tension, and from the balanced condition to maximum compression. Standardmäßig, the program uses 40 Punkte, and you can change this number.

For axial force with biaxial bending, the program uses 3D N-Mx-My interaction surfaces based on the Bresler load contour method: it calculates a set of N-M curves separately, then generates the 3D surface from them with the load contour method. The design report describes these calculations in detail.
Strength Reduction and Partial Safety Factors
Für AS 3600, select the reinforcement class. It is used to calculate the strength reduction factor φ.

Für einen 2, define the partial safety factors. They are used to calculate the ultimate strength forces.

Creep Parameters
Serviceability limit state checks, such as crack control, need to account for long-term effects in the concrete. Im Creep Parameters, you can define the ages at which creep begins and ends, and the relative humidity (IM 2) or arid environment (AS 3600).

Stäbe
In the standalone module, you can define as many members as you need, each as a beam or a column. Enter the clear length of each member. Column members also need an effective length.


Deflection Coefficient (SkyCiv Beam)
Im SkyCiv Beam, where all members are beams, you enter a typical deflection coefficient. It is used to calculate the deflection of the beam with a cracked section.

The table below gives typical deflection coefficients for different cases of beam bending.

RC-Layouts
For each member to design, define the section, the reinforcement and the material properties:
- Querschnitt: choose the section type and enter its dimensions.
- Verstärkung: define the longitudinal reinforcement and the shear reinforcement (Steigbügel). You can place bars at any longitudinal and transverse position in the member. If no shear reinforcement is defined, the design check calculates the shear capacity with the longitudinal reinforcement only.
- Materialien: enter the strength properties of the concrete and steel, and the crack width limit.

Sobald alle Daten für das Mitglied definiert sind, klicken Sie auf Speichern to apply the RC layout. A layout that is not saved is not used in the design check.
Kräfte
In the standalone module, you enter the design forces manually in two tables: one for the ultimate limit state checks and one for the serviceability limit state checks. Forces are defined at sections along the member, with no limit on the number of sections. Klicken Sie auf Neuen Punkt hinzufügen to add a section, then enter its position (as a percentage of the member length) and the forces acting at that location.

Im SkyCiv Beam, the forces are taken automatically from the beam analysis, so you only define the number of sections to design and their positions along the member.

Once all the data is defined, klicken Sie auf Speichern, otherwise it is not used in the design check.
Lastkombinationen
To use load combinations, first define the load type of each load applied to the beam model.

Im Kombinationen Tab, define all the load combinations needed for the strength and serviceability checks. Standardmäßig, the program generates a set of standard load combinations for the chosen design code, which you can edit and add to. A load type is only included in a combination if its factor in that combination is not zero.

When the table is complete, klicken Sie auf Speichern.
Ergebnisse
Once all the inputs for the concrete member are complete, klicken Sie auf Design prüfen to run the design. Das Ergebnisse tab shows the design checks and their capacity ratios: each check, such as flexure, shear force and crack control, has its own ratio. For a closer look at the design calculations, click the report icon at the end of a row to generate a detailed design report of the checks. The report includes every check formula with its parameters, and detailed hand calculations for the design of the reinforced concrete section.