SkyCiv Load Generator calculates ASCE 7-22 seismic loads for buildings with the Equivalent Lateral Force (ELF) procédure. It looks up the seismic design parameters for your site, then gives you the seismic base shear, the vertical distribution of forces per floor, the diaphragm forces and the design response spectrum. This page explains each input in the seismic workflow and how the calculation uses it.
Free accounts can try the workflow with limited solves. With a Professional Account or the module Load Generator autonome, you get unlimited use of every feature, including the detailed seismic calculation report.
Workflow Overview
The workflow follows the same top-to-bottom order as the rest of the SkyCiv Load Generator:
- Sélectionner ASCE 7-22 as the design code and the unit system (Impérial ou métrique).
- Dans Données du site, enter the location, the Risk Category and the Site Class.
- Dans Données de la structure, sélectionnez le Bâtiment structure and enter its dimensions.
- Forces/moments de déviation Analyse non linéaire à l'aide de la théorie des petits déplacements Les résultats 3D structurels ont été comparés à un logiciel d'analyse tiers Charge sismique and define the seismic parameters.
- Cliquez sur Calculer les charges and review the results.
Pour ASCE 7-22, the seismic calculation is available for the Bâtiment structure. For the ASCE 7-16 en ligne, which also covers solar panels and rooftop equipment, voir ASCE 7-16 Calculs de charge sismique.
Données du site: Seismic Design Parameters
Entrez l'adresse du projet (or drop a pin on the map) et réglez le Catégorie de risque. Sous For Seismic Load, sélectionnez le Classe de site from the ASCE 7-22 liste:
- Default Site Conditions
- A – Hard rock
- B – Medium hard rock
- Colombie-Britannique – Soft rock
- C – Very dense sand or hard clay
- CD – Dense sand or very stiff clay
- D – Medium dense sand or stiff clay
- DE – Loose sand or medium stiff clay
- E – Very loose sand or soft clay
The Site Class follows Table 20.2-1 de l'ASCE 7-22. SkyCiv then fetches the seismic hazard values for the location and shows them under Données sismiques USGS:
| Paramètre | Signification | How it is used |
|---|---|---|
| \( S_{1} \) | Mapped maximum considered earthquake (MCE) spectral response acceleration at a 1 s period | Hazard input at long periods |
| \( T_{L} \) | Période de transition de longue durée | Sets where the design response spectrum changes from constant velocity to constant displacement |
| \( S_{DS} \) | Design spectral response acceleration at short periods | Controls the plateau of the design spectrum and the short-period seismic response coefficient |
| \( S_{D1} \) | Design spectral response acceleration at a 1 s period | Controls the long-period branch of the spectrum |
| \( T_{0} = 0.2 S_{D1} / S_{DS} \) | Start of the spectrum plateau | Defines the shape of the design response spectrum |
You can edit any of these values if your project uses site-specific results, for example from a site response analysis. All of them, together with the Site Class, must have a value before the seismic calculation can run.
Seismic Load Parameters for Buildings
Cliquez sur Charge sismique to open the seismic parameters. The seismic checkbox beside the button is checked automatically when the site values are complete. These are the building inputs:
- Structure System: the lateral system of the building (steel moment-resisting frames by default, concrete moment-resisting frames, steel eccentrically braced frames, steel buckling-restrained braced frames, or all other structural systems). It sets the coefficients \( C_{t} \) et \( x \) of Table 12.8-2, which are shown in the dropdown for the unit system you selected.
- Période fondamentale de la structure, T (ou \( T_{a} \)): when you pick a Structure System, SkyCiv fills this field with the approximate period \( T_{a} = C_{t} h_{n}^{x} \), using the roof mean height from Structure Data as \( h_{n} \). You can overwrite it with a period from a dynamic analysis, par exemple SkyCiv S3D Dynamic Frequency Analysis. A longer period lowers the base shear, so check any value you override.
- Facteur de modification de la réponse, R: la valeur par défaut est 3.5. Take the value for your seismic force-resisting system from Table 12.2-1 (or Tables 12.14-1, 15.4-1 et 15.4-2 where they apply). The base shear is inversely proportional to R.
- Redundancy Factor, ρ: sélectionnez 1.0 (défaut) ou 1.3 according to Section 12.3.4. It is used in the diaphragm force calculation.
- Poids des étages: a table of Level, Elevation and Weight for each floor. Utiliser Add Floor Weights Data to add rows and Clair to empty the table. The total weight gives the seismic base shear, and each floor’s weight and height drive the vertical distribution of forces.
How the Parameters Work Together
In the Equivalent Lateral Force procedure, the Site Class and the hazard values \( S_{DS} \) et \( S_{D1} \) define the design response spectrum. The period \( T \) is read on that spectrum to get the seismic response coefficient \( C_{s} \), which is reduced by \( R \) and increased by the importance of the building (from the Risk Category). The seismic base shear is then:
[math] V = C_{s} W [math]
où \( W \) is the effective seismic weight from the Floor Weights table. The base shear is distributed over the height of the building in proportion to the weight and elevation of each floor, which gives the force at each level. The redundancy factor \( ρ \) is applied when the diaphragm forces are calculated.
Calculate Loads and Review the Results
Cliquez sur Calculer les charges at the upper right. Le Charge sismique results tab shows:
- Seismic Parameters: every input and derived value used in the calculation.
- Répartition verticale des forces sismiques: the force at each floor and the base shear.
- Diaphragm forces: the floor diaphragm design forces.
- Spectre de réponse: the design response spectrum generated for your site.
Detailed Seismic Calculation Report
Le Detailed Seismic Calculation Report is a Premium feature. It lists every equation, parameter and assumption used in the calculation, so you can check the result and attach it to your design documentation. It is available with a Professional Account or the standalone Load Generator module.
For wind loads on the same project, voir ASCE 7-22 Calculs de la charge du vent.