Τεκμηρίωση SkyCiv

Ο οδηγός σας για το λογισμικό SkyCiv — σεμινάρια, οδηγοί και τεχνικά άρθρα

Οδηγός χρήσης: Σχέδιο πλάκας βάσης CSA

This page walks through a fixed base plate design to CSA S16:19 και CSA A23.3:19 in SkyCiv Base Plate Design. It covers each input tab and sub-tab in order, the Settings window, the info panel and 3D viewer, the Results tab, the calculation reports and the detail drawing.

The steps across the top of the input panel are Λεπτομέριες, Γεωμετρία, Άγκυρες, Συγκολλήσεις, Column Loads και Αποτελέσματα. You can move between them in any order. The 3D model on the right updates as you change the inputs.

This guide uses a fixed base plate. Pinned base plates are also available.

CSA designs use metric units. Default values are those of the I-shaped column template unless stated otherwise.

Starting a design

Open SkyCiv Base Plate Design from the SkyCiv dashboard or from platform.skyciv.com/design/base-plate/v2. The start window opens with two inputs:

  1. Κανονισμός σχεδιασμού: επιλέξτε CSA S16:19 και CSA A23.3:19. The first standard applies to the steel elements and the second to the foundation.
  2. Base Plate Template: επίλεξε το Fixed Base Plate αυτί, then click the card for the column shape: I-Shaped Column, Rectangular Column ή Circular Column.

A fixed base plate restrains column rotation at the base, so bending moments are transferred to the foundation.

Clicking a card loads the template and closes the window. There is no separate New button. The template sets the starting column section.

The top-right of the window also has Διαχείριση αρχείων (open a saved file) και Ανέβασμα αρχείου (load a .json αρχείο).

Details tab

Το Λεπτομέριες tab holds the project information and project-wide options. It has no sub-tabs.

Εισαγωγή Περιγραφή
Κανονισμός σχεδιασμού The current design code. Changing it resets all design parameters and reloads the page, after a confirmation. Nothing from the current design is kept.
Τύπος υποστήριξης Καρφιτσώθηκε ή Σταθερός. Changing it, after a confirmation, rebuilds the Anchors tab (tension zones and groups) and the Column Loads tab. Γεωμετρία, welds and settings are kept.
Μονάδες Έργου Always Μετρικός for CSA. The dropdown is disabled. Βλέπω Project units.
Όνομα έργου, Εταιρία, Σχεδιαστής, Αναγνωριστικό έργου, Πελάτης Free text. Saved with the file and shown in the calculation report and the drawing title block.
Σημειώσεις έργου Free text for project notes.
Προηγμένες ρυθμίσεις Opens the Settings window. Βλέπω Ρυθμίσεις.

Project units

Ποσότητα Μονάδα
Μήκος χιλ
Δύναμη λόγω σκυροδέματος ΚΝ
Στιγμή kN-m
Steel strength MPa
Αντοχή σκυροδέματος MPa

Ρυθμίσεις

Κάντε κλικ Προηγμένες ρυθμίσεις on the Details tab to open the Ρυθμίσεις παράθυρο. It has three tabs: Παράγοντες & Other Inputs, Σχέδιο και Λεπτομέρειες.

Κάντε κλικ Αποθηκεύσετε to keep your changes. If you click Κοντά with unsaved changes, you are asked whether to Discard ή Αποθηκεύσετε τους. Changing a setting after a design has run does not re-run it. The Results tab shows Τα αποτελέσματα χρειάζονται ενημέρωση until you run the design checks again.

Παράγοντες & Other Inputs

This tab lists the resistance factors (Φ), the resistance modification factors (Ρ) and the concrete normal weight factor used in the design checks.

Resistance Factors (Φ)

Παράγοντας Επιλέξτε είτε Z είτε Y-Axis Αναφορά
Σκυρόδεμα 0.65 CSA A23.3:19 Ρήτρα 8.4.2 (φντο); CSA S16:19 Ρήτρα 13.1(ι)
Συγκόλληση 0.67 CSA S16:19 Ρήτρες 13.1(η) και 13.13.1 (φβ, weld metal)
Ατσάλι 0.90 CSA S16:19 Ρήτρα 13.1(ένα) (φ, δομικού χάλυβα)
Ατσάλι (Τελικός) 0.75 CSA S16:19 Ρήτρα 13.1(ένα) (φεσύ, δομικού χάλυβα)
Ράβδος άγκυρας (CSA S16) 0.67 CSA S16:19 Ρήτρες 13.1(Εγώ) και 25.3.2.1 (φΜε, ράβδοι αγκύρωσης)
Ράβδος άγκυρας (CSA A23.3) 0.85 CSA A23.3:19 Ρήτρα 8.4.3(ένα) (φμικρό, embedded steel anchors)

The two anchor rod factors are separate inputs. Ράβδος άγκυρας (CSA S16) is φΜε from CSA S16 and Ράβδος άγκυρας (CSA A23.3) is φμικρό from CSA A23.3.

Resistance Modification Factors, Ρ

Each group has a dropdown that fills the two factors below it. The values are those of CSA A23.3:19 Clause D.5.3.

Dropdown Επιλογή Tension Loads Shear Loads Αναφορά
Anchors Governed by Strength of Steel Ductile (Προκαθορισμένο) 0.80 0.75 CSA A23.3:19 Clause D.5.3(ένα), ductile steel element
Brittle 0.70 0.65 CSA A23.3:19 Clause D.5.3(σι), brittle steel element
Anchors Governed by Strength of Concrete Condition A 1.15 1.15 CSA A23.3:19 Clause D.5.3(ντο), cast-in anchors with supplementary reinforcement
Condition B (Προκαθορισμένο) 1.00 1.00 CSA A23.3:19 Clause D.5.3(ντο), cast-in anchors without supplementary reinforcement

For concrete, the tension factor is labelled Tension Loads (Cast-In). If you type a value in one of the four R factor inputs, its dropdown changes to Εθιμο and your values are kept.

Other Factors

Παράγοντας Επιλέξτε είτε Z είτε Y-Axis Αναφορά
Concrete Normal Weight (λ) 1 CSA A23.3:19 Ρήτρα 8.6.5 (1.00 for normal-density concrete)

Each factor must be a number greater than zero. An invalid factor stops the design from running and shows a link back to the input.

Σχέδιο

This tab controls which checks run and the design assumptions. Design settings should only be changed under the guidance of a suitably qualified engineer.

Έλεγχοι σχεδιασμού

Σύνθεση Επιλέξτε είτε Z είτε Y-Axis Περιγραφή
Neglect Concrete Breakout Check for Tension Μακριά από Skips the tension breakout check. Use only where steel reinforcement designed for the load transfer is present. The reinforcement is not checked by the software.
Neglect Concrete Breakout Check for Shear Μακριά από Skips the shear breakout check, under the same condition.
Neglect Shear Pryout Check if Anchor is Slender (έχω > 12ρε) Επί Skips the pryout check for anchors with hef > 12ρε. Όταν είναι απενεργοποιημένο, pryout is checked for all anchors.

A check that is skipped by these settings is shown greyed out in the results and left out of the report.

Design Assumptions

Σύνθεση Επιλέξτε είτε Z είτε Y-Axis Περιγραφή
Include Embedded Head Radius in Breakout Concrete Cone Επί Includes the extra capacity of the embedded plate by projecting the breakout surface 1.5hef outward from the effective perimeter of the plate.
Allow Shear Distribution to All Anchors Επί Όταν ενεργοποιείται, shear is distributed to all anchors and the failure cases of CSA A23.3:19 Clause D.7.2 apply. Όταν είναι απενεργοποιημένο, shear is taken only by the anchors closest to the concrete edge in the direction of the load (conservative). This setting is locked on when Use Welded Plate Washers is selected on the Anchors tab.
Use Simplified Approach to Calculate Anchor Steel Shear Strength Επί Όταν ενεργοποιείται, the CSA A23.3 method is used: the grout pad thickness is ignored for anchor rod bending and a 0.8 shear strength reduction is applied. Όταν είναι απενεργοποιημένο, the grout pad thickness is included in anchor rod bending and no reduction is applied.
Consider Compression and Tension Effects Perpendicular to the Applied Moment Επί Όταν ενεργοποιείται, the base plate flexural capacity is checked in both the parallel and perpendicular directions for concrete bearing and anchor tension. Όταν είναι απενεργοποιημένο, only the parallel direction is checked. See AISC Design Guide 1, 3έκδοση, Φιγούρα 4-1 for the directions.
Transfer Compression via Welds Only Μακριά από Excludes the column section from compression transfer, so the compression is transferred by the welds only. Intended for lightly loaded connections. Not available for CJP welds.

Λεπτομέρειες

This tab sets which detailing checks run before the design. A detailing check that fails stops the design from running. A check that is turned off is left out of the Results tab and the report.

Ελεγχος Επιλέξτε είτε Z είτε Y-Axis
Weld Size Requirement Επί
Anchor Clearance Επί
Base Plate Edge Distance Επί
Embedded Plate Dimension Επί
Concrete Splitting Check for Anchors in Tension Επί
Minimum Number of Anchors Επί
Design Layout (Απαιτείται) Πάντα αναμμένο

Design Layout checks the model for clashes and unsupported layouts and cannot be turned off. The weld size check does not apply to CJP welds.

Geometry tab

Το Γεωμετρία tab has three sub-tabs: Στήλη, Πλάκα βάσης και Σκυρόδεμα. Each sub-tab has a 2D drawing above its inputs. The drawings are included in the calculation report.

Text inputs are checked when you leave the field. An error (το κόκκινο) or a warning (πορτοκάλι) appears under the input. Values with errors are listed again on the Results tab and stop the design from running.

Στήλη

Εισαγωγή Περιγραφή
Σχήμα I-Shape, Ορθογώνιος ή Pipe. Changing the shape also changes the anchor patterns available on the Anchors tab.
Βάση δεδομένων CISC sections. I-Shape: WWF: Welded Wide Flange, Δ: Φαρδιά φλάντζα, WRF: Welded Reduced Flange, Στρογγυλό HSS, Στρογγυλό HSS, SLB: Super-Light Beams, Στρογγυλό HSS. Ορθογώνιος: HSS G40.21-C Rectangular and Square, HSS A500-C Rectangular and Square. Pipe: HSS G40.21-C Round, HSS A500-C Round.
Profile The section from the selected database. The section library is the same one used in SkyCiv Section Builder. Changing the shape or database selects the first profile in the list.
Υλικό χάλυβα CSA G40.21 steel grades for the column (230G to 700QT). Επιλέγω Εθιμο at the end of the list to enter your own strengths.
Yield Stress Shown for Custom material only.
Αντοχή εφελκυσμού Shown for Custom material only. Must not be less than the yield stress.

The column drawing shows the section with its main dimensions: flange width and thickness, web thickness and depth for an I-shape; σι, h and t for a rectangular section; D and t for a pipe.

Πλάκα βάσης

Εισαγωγή Περιγραφή
Plate Width Plate dimension along the Z-axis.
Plate Length Plate dimension along the Y-axis.
Πάχος πλάκας Thickness of the base plate.
Υλικό χάλυβα CSA G40.21 steel grades for the plate, ή Εθιμο.
Yield Stress, Αντοχή εφελκυσμού Shown for Custom material only.
Πάχος ενέματος Thickness of the grout pad. Επίλεξε το 0 for no grout pad.

For this guide, enter a Πάχος ενέματος του 25 mm to add a grout pad.

Auto-Size Base Plate Dims sets the plate width and length to suit the column, so the plate is larger than the column section. Use it after changing the column section. The anchor layout is updated with the plate.

The base plate drawing shows the plate in plan with the column outline and the plate width and length.

Σκυρόδεμα

Εισαγωγή Περιγραφή
Use Cracked Concrete Cracked concrete at service loads is the conservative default. Only assume uncracked concrete if it is justified by analysis.
Πλάτος Concrete dimension along the Z-axis.
Μήκος Concrete dimension along the Y-axis.
Πάχος Thickness of the concrete foundation.
Concrete Compressive Strength 20.68, 27.68, 31.03, 34.47 ή 41.36 MPa, ή Εθιμο.
Custom Compressive Strength Shown for Custom only. Cannot exceed 70 MPa (CSA A23.3:19 Clause D.4.7).

Auto-Size Concrete Dims sets the concrete width and length to suit the base plate, so the concrete is larger than the base plate.

Changing the concrete width or length updates the distances from the anchors to the concrete edge, which are used for the anchor groups and the detailing checks.

The concrete drawing shows the concrete in plan with the base plate and column outlines and the concrete width and length.

Anchors tab

Το Άγκυρες tab has three sub-tabs: Ιδιότητες, Θέση και Failure Modes. All anchors are cast-in and have the same properties.

Ιδιότητες

Εισαγωγή Περιγραφή
Διάμετρος 12.7, 15.9, 19.1, 22.2, 25.4, 28.6, 31.8, 34.9, 38.1, 44.5 ή 50.8 χιλ.
Μήκος ενσωμάτωσης, έχω Effective embedment depth, measured as shown in the drawing. The total anchor length must fit within the concrete thickness.
Υλικό χάλυβα Βαθμός ASTM F1554 36, 55 ή 105, ASTM A193, ή Εθιμο.
Yield Stress, Αντοχή εφελκυσμού Shown for Custom material only. The tensile strength must not be less than the yield stress.
Νήματα σε επίπεδο διάτμησης Συμπεριλαμβανομένος (N bolts, conservative) ή Excluded (X bolts).
Ending Straight, Ορθογώνιο Πλάκα, Κυκλική πλάκα ή Hooked. A straight ending cannot be used when the anchors are in tension.
Installation Type Only cast-in anchors are supported.
Use Welded Plate Washers Adds welded plate washers. Όταν επιλεγεί, Allow Shear Distribution to All Anchors is turned on and locked in Settings. When cleared, that setting is unlocked and turned off.
Plate Washer Thickness Shown when Use Welded Plate Washers Η μετάβαση από το σημείο αποσυμπίεσης στην καθαρή κάμψη χρησιμοποιεί έναν παράγοντα μείωσης της αντοχής του. Must be greater than zero.

The ending adds these inputs:

Ending Εισροές
Straight Κανένας
Ορθογώνιο Πλάκα Embedded Plate Width, σι και Embedded Plate Thickness, τ. A width of 4 times the anchor diameter is typically recommended. The width cannot be less than the anchor diameter.
Κυκλική πλάκα Embedded Plate Diameter, σι και Embedded Plate Thickness, τ, with the same limits.
Hooked Hook Length, eh, between 3d and 4.5d. Hook Direction (Τώρα συνεχίστε και προσθέστε τους ακόλουθους τέσσερις κόμβους για να ολοκληρώσετε το πλαίσιο του αετώματος, Εμπρός, Αριστερά, σωστά, Outward, Inward) sets the hook direction in the 3D model only.

Auto-Size Dims sets the embedded plate width or the hook length relative to the anchor diameter. It is hidden for straight anchors.

The elevation drawing shows one anchor through the base plate and grout into the concrete, with hef and the embedded plate or hook dimensions.

Θέση

The Position sub-tab sets the anchor layout. The plan drawing at the top shows the base plate, column and anchors with their IDs, edge distances and spacings.

Select a pattern in Select Anchor Pattern. The patterns depend on the column shape:

Column shape Μοτίβα
I-Shape Γωνίες, Μόνο φλάντζα, Μόνο Web
Ορθογώνιος Γωνίες, Top/Bottom Walls of Profile, Left/Right Walls of Profile, Όλες οι πλευρές
Pipe Γωνίες

Το Guide to SkyCiv Anchor Patterns shows each pattern. Changing the pattern resets the position inputs to the defaults of that pattern.

The position inputs that can be edited depend on the pattern. The others are calculated and shown greyed out.

Εισαγωγή Γωνίες Μόνο φλάντζα, Top/Bottom Μόνο Web, Left/Right Όλες οι πλευρές
Number of Anchors per Side Fixed at 1 (4 άγκυρες) Editable Editable –
Number of Anchors along Z-axis / Άξονας Υ – – – Editable
Z-axis Spacing, Y-axis Spacing Επιλέξτε είτε Z είτε Y-Axis Editable Editable Editable
Z-axis Edge Distance, Y-axis Edge Distance Editable Επιλέξτε είτε Z είτε Y-Axis Επιλέξτε είτε Z είτε Y-Axis Editable

The edge distance is measured from the edge of the base plate to the centre of the nearest anchor. It cannot be more than half the plate dimension.

Plate Bending Direction for Web Anchors Nearest Flange is shown for I-shaped columns that have more than one web anchor per side. Neglect Flanges (Προκαθορισμένο) assumes all anchor loads bend the plate toward the column web. Consider Flanges assumes anchors near the flange bend the plate toward the flange.

Anchor Tension Zones: επιλέξτε Εμφάνιση ζωνών τάσης για κάμψη ισχυρού άξονα ή Εμφάνιση ζωνών τάσης για κάμψη ασθενούς άξονα to shade the zone on the plan drawing. Only anchors within a tension zone resist tension from that moment:

  • Strong-axis bending (Μζ): anchors beyond the column flanges, at a distance of at least half the column depth from the centre.
  • Weak-axis bending (Καμπύλες Mz-My και καμπύλες F-M): anchors beyond half the flange width (half the width b for a rectangular column, half the diameter for a pipe).

A corner anchor can be in both zones.

The menu below the inputs has three tables:

  • Anchor Coordinates Summary: the ID and the Z and Y coordinates of each anchor, measured from the centre of the plate.
  • Tension Anchors Summary: three tabs, All in Tension, Strong-axis Bending και Weak-axis Bending. For each anchor, the table shows whether it is in the tension zone, the moment direction it resists (+Μζ, −Mz, +Καμπύλες Mz-My και καμπύλες F-M, −My), and its group for concrete breakout and side-face blowout in Y and Z. Anchors whose 3hef projected areas overlap form a group, and the others are shown as Single. N/a means side-face blowout does not occur because the anchor is far enough from the concrete edge.
  • Shear Anchors Summary: for each anchor, the shear direction it resists and its group for concrete breakout and pryout in Vy and Vz. Με Allow Shear Distribution to All Anchors επί, all anchors resist shear in all directions. With it off, +Vz is taken by the right-most column of anchors, −Vz by the left-most, +Vy by the top row and −Vy by the bottom row.

Failure Modes

Το Concrete Failure Mode Illustration Guide shows the projected concrete areas for each failure mode on your anchor layout, σε σχέδιο, front and side views. It has no inputs that affect the design. The capacities are calculated when the design runs.

If the influence areas of several anchors overlap, the anchors are treated as an anchor group. If they do not overlap, the anchors are treated as single anchors.

A message replaces the figure when the selected mode does not apply, for example when no anchors are in the tension zone, or when side-face blowout does not occur because the anchors are far enough from the edge. Side-face blowout does not apply to hooked or straight anchors.

The failure mode figures are included in the calculation report.

Welds tab

Το Συγκολλήσεις tab sets the weld between the column and the base plate. The welds are shown in the 3D model only.

Εισαγωγή Περιγραφή
Weld Type Συγκόλληση φιλέτου ή Πλήρης αρθρική διείσδυση (CJP).
Weld Electrode Classification E43XX-X to E83XX-X, ή Εθιμο.
Weld Material Strength Shown for Custom only.
Μέγεθος συγκόλλησης, ρε The leg size of the fillet weld. One size is used for the flanges and the web.
Weld Setback I-shaped columns only. Length near the root radius that is not welded. Επίλεξε το 0 if not used. Cannot exceed the flat length of the flange or web.

For an I-shaped column, ο Weld Details table lists the top flange, bottom flange and web welds with the weld size. The values follow the Weld Size input. For rectangular and pipe columns, one weld size applies around the whole perimeter.

Overmatched electrode: CSA S16:19 Ρήτρα 13.13.1 refers to CSA W59 for the matching electrodes of CSA G40.21 steels. An electrode with a higher strength than the matching electrode is an overmatched electrode. The check compares resistances, not only material strengths. The weld metal fails on the throat, which is inclined at 45°, so its area is D/√2 per unit length of weld. The base metal fails on the fusion face, which has an area of D per unit length. The electrode is overmatched when the weld metal resistance on the throat is greater than the base metal resistance on the fusion face. This happens when Xεσύ × D/√2 > φάεσύ × Δ, αυτό είναι, when Xεσύ > √2 × Fεσύ of the base plate or column material. In that case the design does not run. The Results tab then shows "The electrode strength overmatched the base plate or column material strength" with a link back to Weld Electrode Classification.

Auto-Size Weld sets the weld size to the minimum of CSA W59-13 Table 4.4 for the thicker of the parts joined. This is the general case of Table 4.4. W59-13 lets you use the thinner part instead for low-hydrogen consumables (H8 or lower). Βλέπω Minimum Size of Fillet Welds (CISC). It is a geometric minimum and does not consider the weld strength.

Για ένα CJP συγκόλληση, το μέγεθος, setback and Auto-Size Weld are hidden. Transfer Compression via Welds Only is turned off and disabled in Settings.

Transfer Compression via Welds Only is set in Ρυθμίσεις > Σχέδιο. The link on this tab opens it.

Column Loads tab

Το Column Loads tab holds the factored load combinations. Each row is one combination. There is no load combination generator.

Στήλη Μονάδες Περιγραφή
LC Load combination number, assigned automatically.
Μμε kN-m Strong-axis bending moment.
Μκαι kN-m Weak-axis bending moment.
ΝΧ ΚΝ Αξονική δύναμη. Positive is compression and negative is tension.
Βμε ΚΝ Shear along the plate width (ΜΕ). The sign sets the direction.
Βκαι ΚΝ Shear along the plate length (ΚΑΙ). The sign sets the direction.
Moment Case Χαμηλός ή Μεγάλο, calculated per AISC Design Guide 1, 3έκδοση. Read only.

Notes on the load table:

  • Biaxial bending is not supported. When you enter Mμε, the Mκαι cell of that row is disabled, and the reverse.
  • At least one combination must have a moment, because the support is fixed.
  • Κάντε κλικ + to add a row and - to remove the last row. The delete icon removes a specific row.
  • You can paste rows from a spreadsheet. If a pasted row has both Mμε Οποιοσδήποτε συνδυασμός αξονικού φορτίου και ροπής κάμψης εκτός του διαγράμματος θα προκαλέσει αστοχίακαι, both are set to zero and a message is shown.
  • Rows with all values zero are removed when the design runs.

Το Moment Case is recalculated when Mμε, Μκαι or NΧ αλλαγές. With compression, it compares the eccentricity e = M / N with the critical eccentricity based on the maximum bearing stress, SkyCiv Renderer API Σκυρόδεμα resistance factor from Settings. With tension, it compares e with the distance from the plate centre to the tension anchors. A moment with no axial force is a Μεγάλο moment case.

Load arrows are shown in the 3D model while the Column Loads tab is open. The first combination is shown when you open the tab. Click a row to show that combination. Επιλέγω Skip Load Arrow Rendering to turn the arrows off, which can make editing large tables faster.

Info panel

The info panel sits in the top-left corner of the 3D viewer and summarises the model:

Row Περιεχόμενο
Κανονισμός σχεδιασμού CSA S16:19 και CSA A23.3:19
Στήλη Section and material
Πλάκα βάσης Width × length × thickness and material
Σκυρόδεμα Width × length × thickness and compressive strength
Άγκυρες Diameter and material
Συγκολλήσεις Μέγεθος συγκόλλησης, type and electrode (CJP welds show no size)

Click the arrow next to the heading to collapse the table. The panel updates when the inputs change and is included in the viewer screenshot.

3D viewer

The 3D viewer shows the column, πλάκα βάσης, grout, σκυρόδεμα, anchors and welds. Dimensions are shown on the Geometry tab (concrete and base plate) and the Anchors tab (άγκυρες). Load arrows are shown on the Column Loads tab.

Viewer buttons

The buttons on the right edge of the viewer, from top to bottom:

Κουμπί Περιγραφή
Γυρίζω Left-drag rotates the model. This is the default mode.
Pan Left-drag pans the model.
Ανίπταμαι διαγωνίως Left-drag zooms the model.
Επίδειξη / Hide dimensions Shows or hides the dimension lines.
Fit model to view Centres and zooms on the model, keeping the current view angle.
Switch to orthographic / perspective view Toggles the camera type. Perspective is the default.
Download the 3D model (IFC) Downloads the model as an IFC4 file.
Download an image of the model Downloads a PNG of the current view on a white background, with the info panel.

In all modes, right-drag pans and the mouse wheel zooms.

View cube

The view cube in the bottom-left corner has the faces TOP, BOT, FRONT, BACK, LEFT and RIGHT. Click a face or a corner to turn the camera to that view.

Plan view

The small plan in the top-right corner shows the base plate, στήλη, anchors and welds from above, with the Z (οριζόντιος) και Υ (κατακόρυφος) τσεκούρια. It updates with the inputs.

Bottom bar

The bar under the viewer shows:

  • Σεμινάρια, which starts the guided tour
  • What’s New, which opens the release notes
  • the version number, which opens the changelog
  • the file name, which saves the file when clicked

Καρτέλα Αποτελέσματα

Ανοίξτε το Αποτελέσματα tab to run the design. Before the design runs, the inputs, the design layout and the detailing checks are validated.

  • If the validation passes, the design runs. Until the first successful run, opening the Results tab runs the design automatically.
  • If the validation fails, the design does not run. ΕΝΑ Design Checks Unavailable message lists each problem with a Click here to modify link to the input. If there are only warnings, Click here to proceed anyway runs the design. If a detailing check fails, the message links to Ρυθμίσεις > Λεπτομέρειες.
  • After a run, if you change an input, the results are blurred and a Τα αποτελέσματα χρειάζονται ενημέρωση message is shown. Κάντε κλικ Εκτελέστε ελέγχους σχεδιασμού to run the design again.

Run banner

The banner at the top shows the outcome:

Banner Εννοια
Ολοκληρώθηκε ο σχεδιασμός & Πέρασε All checks passed. The calculation report and the detail drawing are available.
Ολοκληρώθηκε ο σχεδιασμός & Αποτυχημένος One or more checks failed. The calculation report is available. The detail drawing is available only after all checks pass.

The banner has the Προβολή λεπτομερούς σχεδίου και Προβολή αναφοράς υπολογισμού κουμπιά.

Detailing Checks Summary

Each detailing check that is turned on in Ρυθμίσεις > Λεπτομέρειες is listed with a pass or fail icon and its minimum, maximum and actual values. Some checks have an information icon with the code clause. The last row is Design Layout, which shows No conflicts detected or lists each conflict with a link to the input.

For a fixed support, the design layout check requires that:

  • at least one combination has a moment
  • no combination has both Mμε Οποιοσδήποτε συνδυασμός αξονικού φορτίου και ροπής κάμψης εκτός του διαγράμματος θα προκαλέσει αστοχίακαι
  • each tension zone has only one row of anchors

Σχεδιασμός Έλεγχοι Περίληψη

Each design check is listed with:

  • a status icon: a green tick (πέρασμα), a red cross (αποτυγχάνω) or a grey minus (skipped by a Design setting)
  • the check name
  • the demand and capacity
  • LC n: the governing load combination
  • the utilization ratio: green when the ratio is less than 1.0, red when it is 1.0 ή περισσότερα

Each row shows the result of the governing load combination, which is the one with the highest ratio. A check that does not apply to any combination shows N/a. A check skipped by a Design setting shows "-" and the note This design check is excluded from the report based on user settings.

The step-by-step calculations for each check are in the calculation report.

If the server returns an error for the design, ένα Design Check Requires Attention message lists the issues.

Calculation report

Κάντε κλικ Προβολή αναφοράς υπολογισμού in the run banner and choose a report:

Κανω ΑΝΑΦΟΡΑ Περιεχόμενο
Πλήρης έκθεση Step-by-step calculations with diagrams
Αναφορά Lite Βήμα προς βήμα υπολογισμούς, no diagrams
Συνοπτική αναφορά Check results only, no calculation steps

The report opens in a window with Άνοιγμα σε Νέα καρτέλα, Λήψη HTML και Λήψη PDF. The PDF is named after the file name in the bottom bar.

Detail drawing

Κάντε κλικ Προβολή λεπτομερούς σχεδίου in the run banner to open the Structural Drawing παράθυρο. The button is available after all checks pass. In the free version, the drawing preview always opens and shows a watermark.

The drawing sheet has these views:

  1. Plan view
  2. Θέα σε υψόμετρο
  3. Typical anchor detail
  4. 3D view

It also has the drawing notes, ένα πρόγραμμα φόρτωσης και ένα μπλοκ τίτλου.

The preview on the left is a quick sketch. Use the zoom bar in the top-right corner of the preview to zoom in or out or to fit the full page. You can also drag to pan, use the mouse wheel to zoom, and double-click to fit.

Drawing Settings στα δεξιά:

Ενότητα Εισροές
Ρύθμιση σελίδας Page Size (A4 to A0, Letter, Νομικός, Tabloid), Drawing Scale, Detail Scale, Annotation Scale. Από προεπιλογή, the page size is the smallest A size that fits the drawing.
Mark-ups Labels for the Στήλη, Πλάκα βάσης, Αγκυρα, Σκυρόδεμα και, for plate endings, Embedded Plate. Filled from the design.
Drawing Notes The notes printed on the sheet.
Title Block Information Πελάτης, Όνομα έργου, Αναγνωριστικό έργου, Εταιρία, Drawing Title και Σχεδιαστής. Filled from the Details tab.

Κάντε κλικ Update Preview to apply the settings to the preview. The settings are not saved and are reset each time you open the window.

Έχοντας τα «Στιγμιότυπα οθόνης που καθορίζονται από το χρήστη

Έχοντας τα «Στιγμιότυπα οθόνης που καθορίζονται από το χρήστη creates a PDF of the drawing and downloads it.

Εξαγωγή στο CloudCAD

Εξαγωγή στο CloudCAD opens the drawing in SkyCiv CloudCAD, where you can edit it further.

Free version

The free version of SkyCiv Base Plate Design has these limits for a CSA fixed design:

Περιοχή Οριο
Start window Διαχείριση αρχείων και Ανέβασμα αρχείου δεν είναι διαθέσιμα.
Γεωμετρία Column Shape, Βάση δεδομένων, Υλικό χάλυβα, Base Plate Steel Material and Concrete Compressive Strength cannot be changed from the template values. The profile can be changed within the template database. Custom materials are not available.
Άγκυρες Υλικό χάλυβα, Νήματα σε επίπεδο διάτμησης, Ending and Failure Mode cannot be changed. The group columns of the Tension and Shear Anchors Summary tables are hidden.
Συγκολλήσεις Weld Type and Weld Electrode Classification cannot be changed.
Column Loads One load combination only. Rows cannot be added or removed, but the values can be edited.
Ρυθμίσεις The detailing checks cannot be turned off. The factors and design settings can be edited.
Αποτελέσματα The banner shows Ολοκληρώθηκε ο σχεδιασμός, without Passed or Failed. Ζήτηση, capacity and ratio are hidden for the anchor, ξέσπασμα σκυροδέματος, pryout, concrete bearing, base plate and interaction checks. Weld checks show their values.
Calculation report Not available.
Detail drawing The preview has a watermark. Page Setup and Drawing Notes cannot be changed. Export to PDF and Export to CloudCAD are not available.
3D viewer The screenshot and IFC buttons are not available. The base plate shows the SkyCiv logo.

Locked items are marked PRO. Selecting one opens the upgrade prompt.

Calculation report and detail drawing generated by SkyCiv Base Plate Design

Πώς μπορούμε να βοηθήσουμε?

×

Μεταβείτε στην κορυφή