SkyCiv Load Generator calculates ASCE 7-22 seismic loads for buildings with the Equivalent Lateral Force (ELF) procedure. It looks up the seismic design parameters for your site, then gives you the seismic base shear, the vertical distribution of forces per floor, the diaphragm forces and the design response spectrum. This page explains each input in the seismic workflow and how the calculation uses it.
Free accounts can try the workflow with limited solves. With a Professional Account or the standalone Load Generator-module, you get unlimited use of every feature, including the detailed seismic calculation report.
Workflow Overview
The workflow follows the same top-to-bottom order as the rest of the SkyCiv Load Generator:
- Selecteer ASCE 7-22 as the design code and the unit system (Imperiaal of metrisch).
- In Locatiegegevens, enter the location, the Risk Category and the Site Class.
- In Structuurgegevens, selecteer de Gebouw structure and enter its dimensions.
- Open Seismische belasting and define the seismic parameters.
- Klik Bereken belastingen and review the results.
we zullen de effecten van topografie op windbelasting op constructies bespreken door de topografische factor te berekenen 7-22, the seismic calculation is available for the Gebouw structuur. For the ASCE 7-16 versie, which also covers solar panels and rooftop equipment, zien ASCE 7-16 Seismische belastingberekeningen.
Locatiegegevens: Seismic Design Parameters
Vul het projectadres in (or drop a pin on the map) en stel de Risicocategorie. Onder For Seismic Load, selecteer de Locatieklasse from the ASCE 7-22 lijst:
- Default Site Conditions
- A – Hard rock
- B – Medium hard rock
- BC – Soft rock
- C – Very dense sand or hard clay
- CD – Dense sand or very stiff clay
- D – Medium dense sand or stiff clay
- DE – Loose sand or medium stiff clay
- E – Very loose sand or soft clay
The Site Class follows Table 20.2-1 van ASCE 7-22. SkyCiv then fetches the seismic hazard values for the location and shows them under Seismische gegevens van USGS:
| Parameter | Betekenis | How it is used |
|---|---|---|
| \( S_{1} \) | Mapped maximum considered earthquake (MCE) spectral response acceleration at a 1 s period | Hazard input at long periods |
| \( T_{L} \) | Overgangsperiode van lange duur | Sets where the design response spectrum changes from constant velocity to constant displacement |
| \( S_{DS} \) | Design spectral response acceleration at short periods | Controls the plateau of the design spectrum and the short-period seismic response coefficient |
| \( S_{D1} \) | Design spectral response acceleration at a 1 s period | Controls the long-period branch of the spectrum |
| \( T_{0} = 0.2 S_{D1} / S_{DS} \) | Start of the spectrum plateau | Defines the shape of the design response spectrum |
You can edit any of these values if your project uses site-specific results, for example from a site response analysis. All of them, together with the Site Class, must have a value before the seismic calculation can run.
Seismic Load Parameters for Buildings
Klik Seismische belasting to open the seismic parameters. The seismic checkbox beside the button is checked automatically when the site values are complete. These are the building inputs:
- Structure System: the lateral system of the building (steel moment-resisting frames by default, concrete moment-resisting frames, steel eccentrically braced frames, steel buckling-restrained braced frames, or all other structural systems). It sets the coefficients \( C_{t} \) en \( x \) of Table 12.8-2, which are shown in the dropdown for the unit system you selected.
- Fundamentele periode van de structuur, T (of \( T_{a} \)): when you pick a Structure System, SkyCiv fills this field with the approximate period \( T_{a} = C_{t} h_{n}^{x} \), using the roof mean height from Structure Data as \( h_{n} \). You can overwrite it with a period from a dynamic analysis, bijvoorbeeld SkyCiv S3D Dynamic Frequency Analysis. A longer period lowers the base shear, so check any value you override.
- Responsmodificatiefactor, R: de standaardwaarde is 3.5. Take the value for your seismic force-resisting system from Table 12.2-1 (or Tables 12.14-1, 15.4-1 en 15.4-2 where they apply). The base shear is inversely proportional to R.
- Redundancy Factor, r: selecteren 1.0 (standaard) of 1.3 according to Section 12.3.4. It is used in the diaphragm force calculation.
- Vloergewichten: a table of Level, Elevation and Weight for each floor. Gebruik Add Floor Weights Data to add rows and Doorzichtig to empty the table. The total weight gives the seismic base shear, and each floor’s weight and height drive the vertical distribution of forces.
How the Parameters Work Together
In the Equivalent Lateral Force procedure, the Site Class and the hazard values \( S_{DS} \) en \( S_{D1} \) define the design response spectrum. The period \( T \) is read on that spectrum to get the seismic response coefficient \( C_{s} \), which is reduced by \( R \) and increased by the importance of the building (from the Risk Category). The seismic base shear is then:
[math] V = C_{s} W [math]
waar \( W \) is the effective seismic weight from the Floor Weights table. The base shear is distributed over the height of the building in proportion to the weight and elevation of each floor, which gives the force at each level. The redundancy factor \( ρ \) is applied when the diaphragm forces are calculated.
Calculate Loads and Review the Results
Klik Bereken belastingen at the upper right. De Seismische belasting results tab shows:
- Seismic Parameters: every input and derived value used in the calculation.
- Verticale verdeling van seismische krachten: the force at each floor and the base shear.
- Diaphragm forces: the floor diaphragm design forces.
- Reactiespectrum: the design response spectrum generated for your site.
Detailed Seismic Calculation Report
De Detailed Seismic Calculation Report is a Premium feature. It lists every equation, parameter and assumption used in the calculation, so you can check the result and attach it to your design documentation. It is available with a Professional Account or the standalone Load Generator module.
For wind loads on the same project, zien ASCE 7-22 Berekeningen van windbelasting.