Documentazione SkyCiv

La Sua guida al software SkyCiv: tutorial, guide pratiche e articoli tecnici

Per iniziare: Design della piastra di base AISC

This page walks through a fixed base plate design to AISC 360-22 e ACI 318-19 in SkyCiv Base Plate Design. It covers each input tab and sub-tab in order, the Settings window, the info panel and 3D viewer, the Results tab, the calculation reports and the detail drawing.

The steps across the top of the input panel are Dettagli, Geometria, Ancore, saldature, Column Loads e Risultati. You can move between them in any order. The 3D model on the right updates as you change the inputs.

This guide uses a fixed base plate. Pinned base plates are also available.

Values in this page are given in imperial units, arrotondato, with metric in brackets.

Starting a design

Open SkyCiv Base Plate Design from the SkyCiv dashboard or from platform.skyciv.com/design/base-plate/v2. The start window opens with two inputs:

  1. Normativa di progetto: seleziona AISC 360-22 e ACI 318-19. The first standard applies to the steel elements and the second to the foundation.
  2. Base Plate Template: seleziona il Fixed Base Plate tab, then click the card for the column shape: I-Shaped Column, Rectangular Column o Circular Column.

A fixed base plate restrains column rotation at the base, so bending moments are transferred to the foundation.

Clicking a card loads the template and closes the window. There is no separate New button. The template sets the starting column section.

Templates are stored in metric. If your SkyCiv account is set to imperial units, the model is converted to imperial after it loads, so the app shows the exact converted values.

The top-right of the window also has File Manager (open a saved file) e Caricare un file (load a .json file).

SkyCiv Base Plate Design start window with AISC 360-22 e ACI 318-19 selezionato, Fixed Base Plate tab and I-Shaped Column card

Scheda Dettagli

Il Dettagli tab holds the project information and project-wide options. It has no sub-tabs.

Details tab of SkyCiv Base Plate Design (AISC 360-22, ACI 318-19) with Fixed support, Unità imperiali, 3D base plate model

Ingresso Descrizione
Normativa di progetto The current design code. Changing it resets all design parameters and reloads the page, after a confirmation. Nothing from the current design is kept.
Tipo di supporto A cerniera o Incastro. Changing it, after a confirmation, rebuilds the Anchors tab (tension zones and groups) and the Column Loads tab. Geometria, welds and settings are kept.
Unità di progetto Imperiale o Metrico. Only AISC lets you change the units. Vedere Project units.
Nome del progetto, Azienda, progettista, ID progetto, Cliente Free text. Saved with the file and shown in the calculation report and the drawing title block.
Note di progetto Free text for project notes.
Impostazioni avanzate Opens the Settings window. Vedere Impostazioni.

Project units

Quantità Imperiale Metrico
Lunghezza pollici mm
Forza kips kN
Momento kip-ft kN-m
Forza dell'acciaio ksi MPa
Forza concreta psi MPa

When you change the units, all dimensions, custom strengths and loads are converted. The column section is reloaded in the new unit system. The concrete strength and the anchor diameter are not converted numerically: they move to the item in the same position in the other list (per esempio, 4000 psi becomes 27.58 MPa, e un 1/2 in anchor becomes 12 mm). The settings factors are unitless and do not change.

Impostazioni

Fai clic su Impostazioni avanzate on the Details tab to open the Impostazioni finestra. It has three tabs: Fattori & Other Inputs, Progettazione e Dettagli.

Fai clic su Salva to keep your changes. If you click Chiudi with unsaved changes, you are asked whether to Discard o Salva loro. Changing a setting after a design has run does not re-run it. The Results tab shows I risultati necessitano di aggiornamento until you run the design checks again.

Fattori & Other Inputs

This tab lists the resistance factors (B = Profondità o diametro della sezione) used in the design checks. Each label has an information icon that shows the code clause. Each group has a Reset to Default button that restores the defaults of that group.

Settings dialog, Fattori & Other Inputs tab: default AISC and ACI resistance factors, with Reset to Default button per group.

Resistance Factors (B = Profondità o diametro della sezione): AISC

Fattore La resistenza alla compressione sarà considerata come da AS4600 Riferimento
Steel Bearing 0.75 AISC 360-22 J7
Steel Flexure 0.90 AISC 360-22 F1(un carico)
Steel Tensile Yielding 0.90 AISC 360-22 J4.1(un carico)
Steel Tensile Rupture 0.75 AISC 360-22 J4.1(b)
Steel Shear Yielding 1.00 AISC 360-22 J4.2(un carico)
Steel Shear Rupture 0.75 AISC 360-22 J4.2(b)
Di seguito è riportato un esempio di alcuni calcoli della piastra di base americana comunemente utilizzati nella progettazione della piastra di base 0.75 AISC 360-22 J3.7
saldature 0.75 AISC 360-22 J2.4, Table J2.5

Resistance Factors (B = Profondità o diametro della sezione): ACI

Fattore La resistenza alla compressione sarà considerata come da AS4600 Riferimento
Cuscinetto in calcestruzzo 0.65 ACI 318-19 Tabella 21.2.1(d)
Anchor Steel in Tension 0.75 ACI 318-19 Tabella 17.5.3(un carico), ductile steel
Anchor Steel in Shear 0.65 ACI 318-19 Tabella 17.5.3(un carico), ductile steel
Concrete Breakout/Blowout in Tension 0.70 ACI 318-19 Tabella 17.5.3(b), cast-in, no supplementary reinforcement
Concrete Breakout in Shear 0.70 ACI 318-19 Tabella 17.5.3(b), cast-in, no supplementary reinforcement
Concrete Pullout 0.70 ACI 318-19 Tabella 17.5.3(c), cast-in
Concrete Pryout 0.70 ACI 318-19 Tabella 17.5.3(c), cast-in

Other Factors

Fattore La resistenza alla compressione sarà considerata come da AS4600
Concrete Normal Weight (λ) 1

Each factor must be a number greater than zero. An invalid factor stops the design from running and shows a link back to the input. Il Reset to Default buttons do not reset λ.

Progettazione

This tab controls which checks run and the design assumptions. Design settings should only be changed under the guidance of a suitably qualified engineer.

Design tab of the SkyCiv Base Plate Design Settings window (AISC) with Design Checks and Design Assumptions toggles

Controlli di progettazione

Collocamento La resistenza alla compressione sarà considerata come da AS4600 Descrizione
Neglect Concrete Breakout Check for Tension Spento Skips the tension breakout check. Use only where steel reinforcement designed for the load transfer is present. The reinforcement is not checked by the software.
Neglect Concrete Breakout Check for Shear Spento Skips the shear breakout check, under the same condition.
Neglect Shear Pryout Check if Anchor is Slender (Avere > 12d) Su Skips the pryout check for anchors with hef > 12d. Quando spento, pryout is checked for all anchors.

A check that is skipped by these settings is shown greyed out in the results and left out of the report.

Design Assumptions

Collocamento La resistenza alla compressione sarà considerata come da AS4600 Descrizione
Allow Shear Distribution to All Anchors Su Quando è acceso, shear is distributed to all anchors and the failure cases of ACI 318-19 Clausola 17.7 fare domanda a. Quando spento, shear is taken only by the anchors closest to the concrete edge in the direction of the load (conservative). This setting is locked on when Use Welded Plate Washers is selected on the Anchors tab.
Use Simplified Approach to Calculate Anchor Steel Shear Strength Su When on and a grout pad is present, the ACI approach with a 0.8 reduction factor is used. Quando spento, the anchor steel is checked for combined shear and axial stress.
Use Two-way Bending at the Bearing Interface (DG1 App. B.4) Su When the cross cantilever governs, the effective width of AISC Design Guide 1 Appendix B.4 (Eqs. B-27 to B-29) si usa. Quando spento, DG1 Eq. 4-51a is used. Applies to fixed supports only.
Transfer Compression via Welds Only Spento Excludes the column section from compression transfer, so the compression is transferred by the welds only. Intended for lightly loaded connections. Not available for CJP welds.
Use kds = 1.0 (directional strength increase not used) Su Quando è acceso, all fillet welds use kds = 1.0 (AISC 360-22 J2.4(un carico)(3)). Quando spento, Eq. J2-5 is used with the load angle. Not available for CJP welds.

Dettagli

This tab sets which detailing checks run before the design. A detailing check that fails stops the design from running. A check that is turned off is left out of the Results tab and the report.

Settings window Detailing tab in SkyCiv Base Plate Design: six detailing checks on, plus Design Layout (Contattaci per la tua prova gratuita di formazione) always on.

Verifica La resistenza alla compressione sarà considerata come da AS4600
Weld Size Requirement Su
Anchor Clearance Su
Base Plate Edge Distance Su
Embedded Plate Dimension Su
Concrete Splitting Check for Anchors in Tension Su
Minimum Number of Anchors Su
Design Layout (Contattaci per la tua prova gratuita di formazione) Sempre attivo

Design Layout checks the model for clashes and unsupported layouts and cannot be turned off. The weld size check does not apply to CJP welds.

Scheda Geometria

Il Geometria tab has three sub-tabs: Colonna, Piastra di base e Calcestruzzo. Each sub-tab has a 2D drawing above its inputs. The drawings are included in the calculation report.

Text inputs are checked when you leave the field. An error (rosso) or a warning (arancia) appears under the input. Values with errors are listed again on the Results tab and stop the design from running.

Colonna

SkyCiv Base Plate Design Column sub-tab with I-Shape, W8x31 in A992 steel, section drawing and 3D base plate model

Ingresso Descrizione
Forma Profilo a I, Rettangolare o Pipe. Changing the shape also changes the anchor patterns available on the Anchors tab.
Banca dati Profilo a I: Forme a W, Forme a S, M shapes, HP shapes. Rettangolare: HSS rettangolare, HSS quadrato, and obsolete rectangular and square tubes. Pipe: HSS tondo, Dopo aver aggiunto i tuoi materiali, devi specificare quali sezioni utilizzerai, and obsolete pipes.
Profile The section from the selected database. The section library is the same one used in SkyCiv Section Builder. Changing the shape or database selects the first profile in the list.
Materiale in acciaio ASTM steel grades for the column. Selezionare costume at the end of the list to enter your own strengths.
Yield Stress Shown for Custom material only.
Resistenza alla trazione Shown for Custom material only. Must not be less than the yield stress.

The column drawing shows the section with its main dimensions: flange width and thickness, web thickness and depth for an I-shape; b, h and t for a rectangular section; D and t for a pipe.

Piastra di base

Base Plate sub-tab of Geometry tab in SkyCiv Base Plate Design, con 1 in Grout Thickness set and the grout pad in the 3D model

Ingresso Descrizione
Plate Width Plate dimension along the Z-axis.
Plate Length Plate dimension along the Y-axis.
Spessore della piastra Thickness of the base plate.
Materiale in acciaio ASTM steel grades for the plate, o costume.
Yield Stress, Resistenza alla trazione Shown for Custom material only.
Spessore della malta Thickness of the grout pad. è un punto fisso nello spazio che non si muove 0 for no grout pad.

For this guide, enter a Spessore della malta di 1 pollici (25 mm) to add a grout pad.

Auto-Size Base Plate Dims sets the plate width and length from the column size, so the plate is larger than the column section. Use it after changing the column section. The anchor layout is updated with the plate.

The base plate drawing shows the plate in plan with the column outline and the plate width and length.

Calcestruzzo

Concrete sub-tab of Geometry tab in SkyCiv Base Plate Design, with Use Cracked Concrete and Auto-Size Concrete Dims marked

Ingresso Descrizione
Use Cracked Concrete Cracked concrete at service loads is the conservative default. Only assume uncracked concrete if it is justified by analysis.
Larghezza Concrete dimension along the Z-axis.
Lunghezza Concrete dimension along the Y-axis.
Spessore Thickness of the concrete.
Concrete Compressive Strength 3000, 4000, 4500, 5000 o 6000 psi (20.68, 27.58, 31.03, 34.47 o 41.36 MPa), o costume.
Custom Compressive Strength Shown for Custom only.

Auto-Size Concrete Dims sets the concrete width and length from the base plate size, so the concrete is larger than the base plate.

Changing the concrete width or length updates the distances from the anchors to the concrete edge, which are used for the anchor groups and the detailing checks.

The concrete drawing shows the concrete in plan with the base plate and column outlines and the concrete width and length.

Anchors tab

Il Ancore tab has three sub-tabs: Proprietà, Posizione e Failure Modes. All anchors are cast-in and have the same properties.

Proprietà

Anchors Properties sub-tab in SkyCiv Base Plate Design: Piatto rettangolare, with embedded plate width and thickness inputs

Ingresso Descrizione
Diametro 3/8, 1/2, 5/8, 3/4, 7/8, 1, 1-1/8, 1-1/4, 1-3/8 o 1-1/2 pollici (10, 12, 16, 20, 22, 24, 27, 30, 33 o 36 mm).
Lunghezza dell'incasso, Avere Effective embedment depth, measured as shown in the drawing. The total anchor length must fit within the concrete thickness.
Materiale in acciaio bulloni (A307, A325, A490), aste di ancoraggio (A36, A193, A354, A449, A572, A588 and F1554 grades), o costume.
Yield Stress, Resistenza alla trazione Shown for Custom material only. The tensile strength must not be less than the yield stress.
Filettature nel piano di taglio Incluso (N bolts, conservative) o Excluded (X bolts).
Ending Straight, Piatto rettangolare, Piastra Circolare o Hooked. A straight ending cannot be used when the anchors are in tension.
Installation Type Only cast-in anchors are supported.
Use Welded Plate Washers Adds welded plate washers. Quando selezionato, Allow Shear Distribution to All Anchors is turned on and locked in Settings. When cleared, that setting is unlocked and turned off.
Plate Washer Thickness Shown when Use Welded Plate Washers è selezionato. Must be greater than zero.

The ending adds these inputs:

Ending Ingressi
Straight Nessuno
Piatto rettangolare Embedded Plate Width, b e Embedded Plate Thickness, t. A width of 4 times the anchor diameter is typically recommended. The width cannot be less than the anchor diameter.
Piastra Circolare Embedded Plate Diameter, b e Embedded Plate Thickness, t, with the same limits.
Hooked Hook Length, eh, between 3d and 4.5d. Hook Direction (e Y si riferisce all'asse y, Davanti, Sinistra, Destra, Outward, Inward) sets the hook direction in the 3D model only.

Auto-Size Dims sets the embedded plate width or the hook length relative to the anchor diameter. It is hidden for straight anchors.

The elevation drawing shows one anchor through the base plate and grout into the concrete, with hef and the embedded plate or hook dimensions.

Posizione

Anchors Position sub-tab in SkyCiv Base Plate Design, with strong-axis tension zones shaded on the plan and the 3D model

The Position sub-tab sets the anchor layout. The plan drawing at the top shows the base plate, column and anchors with their IDs, edge distances and spacings.

Select a pattern in Select Anchor Pattern. The patterns depend on the column shape:

Column shape Modelli
Profilo a I Angoli, Solo flangia, Solo Web
Rettangolare Angoli, Top/Bottom Walls of Profile, Left/Right Walls of Profile, Tutti i lati
Pipe Angoli

Il Guide to SkyCiv Anchor Patterns shows each pattern. Changing the pattern resets the position inputs to the defaults of that pattern.

The position inputs that can be edited depend on the pattern. The others are calculated and shown greyed out.

Ingresso Angoli Solo flangia, Top/Bottom Solo Web, Left/Right Tutti i lati
Number of Anchors per Side Fixed at 1 (4 ancore) Editable Editable –
Number of Anchors along Z-axis / Asse Y – – – Editable
Z-axis Spacing, Y-axis Spacing Calcolato Editable Editable Editable
Z-axis Edge Distance, Y-axis Edge Distance Editable Calcolato Calcolato Editable

The edge distance is measured from the edge of the base plate to the centre of the nearest anchor. It cannot be more than half the plate dimension.

Plate Bending Direction for Web Anchors Nearest Flange is shown for I-shaped columns that have more than one web anchor per side. Neglect Flanges (predefinito) assumes all anchor loads bend the plate toward the column web. Consider Flanges assumes anchors near the flange bend the plate toward the flange.

Anchor Tension Zones: seleziona Mostra zone di tensione per la flessione dell'asse forte o Mostra zone di tensione per la flessione dell'asse debole to shade the zone on the plan drawing. Only anchors within a tension zone resist tension from that moment:

  • Strong-axis bending (Mz): anchors beyond the column flanges, at a distance of at least half the column depth from the centre.
  • Weak-axis bending (Mio): anchors beyond half the flange width (half the width b for a rectangular column, half the diameter for a pipe).

A corner anchor can be in both zones.

The menu below the inputs has three tables:

  • Anchor Coordinates Summary: the ID and the Z and Y coordinates of each anchor, measured from the centre of the plate.
  • Tension Anchors Summary: three tabs, All in Tension, Strong-axis Bending e Weak-axis Bending. For each anchor, the table shows whether it is in the tension zone, the moment direction it resists (+Mz, −Mz, +Mio, −My), and its group for concrete breakout and side-face blowout in Y and Z. Anchors whose 3hef projected areas overlap form a group, and the others are shown as Single. N / A means side-face blowout does not occur because the anchor is far enough from the concrete edge.
  • Shear Anchors Summary: for each anchor, the shear direction it resists and its group for concrete breakout and pryout in Vy and Vz. Con Allow Shear Distribution to All Anchors sopra, all anchors resist shear in all directions. With it off, +Vz is taken by the right-most column of anchors, −Vz by the left-most, +Vy by the top row and −Vy by the bottom row.

Tension Anchors Summary table in SkyCiv Base Plate Design, All in Tension tab, listing anchors 1 per 4 with moment data

Failure Modes

Failure Modes sub-tab of the Anchors tab showing Concrete Breakout in Tension for +Mz anchors, with plan, davanti, side views

Il Concrete Failure Mode Illustration Guide shows the projected concrete areas for each failure mode on your anchor layout, in piano, front and side views. It has no inputs that affect the design. The capacities are calculated when the design runs.

If the influence areas of several anchors overlap, the anchors are treated as an anchor group. If they do not overlap, the anchors are treated as single anchors.

A message replaces the figure when the selected mode does not apply, for example when no anchors are in the tension zone, or when side-face blowout does not occur because the anchors are far enough from the edge. Side-face blowout does not apply to hooked or straight anchors.

The failure mode figures are included in the calculation report.

Welds tab

Il saldature tab sets the weld between the column and the base plate. The welds are shown in the 3D model only.

Welds tab in SkyCiv Base Plate Design: saldatura d'angolo, E70XX, 0.2756 in size, and a Weld Details table for flanges and web

Ingresso Descrizione
Weld Type Saldatura del filetto o Completa penetrazione articolare (CJP).
Weld Electrode Classification E60XX to E120XX, o costume.
Weld Material Strength Shown for Custom only.
Dimensione saldatura, W The leg size of the fillet weld. One size is used for the flanges and the web.
Weld Setback I-shaped columns only. Length near the root radius that is not welded. è un punto fisso nello spazio che non si muove 0 if not used. Cannot exceed the flat length of the flange or web.

For an I-shaped column, il Weld Details table lists the top flange, bottom flange and web welds with the weld size. The values follow the Weld Size input. For rectangular and pipe columns, one weld size applies around the whole perimeter.

Auto-Size Weld sets the weld size to the minimum of AISC 360-22 Table J2.4 for the thinner of the parts joined. It is a geometric minimum and does not consider the weld strength.

Per un CJP saldare, la dimensione, setback and Auto-Size Weld are hidden. Transfer Compression via Welds Only e Use kds = 1.0 are turned off and disabled in Settings.

Transfer Compression via Welds Only is set in Impostazioni > Progettazione. The link on this tab opens it.

Column Loads tab

Il Column Loads tab holds the factored load combinations. Each row is one combination. There is no load combination generator.

Column Loads tab in SkyCiv Base Plate Design with two load combinations, Mz e My, and the Mz moment arrow in the 3D model

Colonna Unità Descrizione
LC Load combination number, assigned automatically.
Mz kip-ft (kN-m) Strong-axis bending moment.
My kip-ft (kN-m) Weak-axis bending moment.
Nx kips (kN) Forza assiale. Positive is compression and negative is tension.
V z kips (kN) Shear along the plate width (Z). The sign sets the direction.
V y kips (kN) Shear along the plate length (E). The sign sets the direction.
Moment Case Basso o Di grandi dimensioni, calculated per AISC Design Guide 1, 3Rd Edition. Read only.

Notes on the load table:

  • Biaxial bending is not supported. When you enter Mz, the My cell of that row is disabled, and the reverse.
  • At least one combination must have a moment, because the support is fixed.
  • Fai clic su + to add a row and - to remove the last row. The delete icon removes a specific row.
  • You can paste rows from a spreadsheet. If a pasted row has both Mz e My, both are set to zero and a message is shown.
  • Rows with all values zero are removed when the design runs.

Il Moment Case is recalculated when Mz, My or Nx i cambiamenti. With compression, it compares the eccentricity e = M / N with the critical eccentricity based on the maximum bearing stress. With tension, it compares e with the distance from the plate centre to the tension anchors. A moment with no axial force is a Di grandi dimensioni moment case.

Load arrows are shown in the 3D model while the Column Loads tab is open. The first combination is shown when you open the tab. Click a row to show that combination. Selezionare Skip Load Arrow Rendering to turn the arrows off, which can make editing large tables faster.

Info panel

The info panel sits in the top-left corner of the 3D viewer and summarises the model:

Row Contenuto
Normativa di progetto AISC 360-22 e ACI 318-19
Colonna Section and material
Piastra di base Width × length × thickness and material
Calcestruzzo Width × length × thickness and compressive strength
Ancore Diameter and material
saldature Dimensione della saldatura, type and electrode (CJP welds show no size)

Click the arrow next to the heading to collapse the table. The panel updates when the inputs change and is included in the viewer screenshot.

SkyCiv Base Plate Design info panel listing AISC 360-22, ACI 318-19, W8x31 column, piastra, calcestruzzo, anchors and fillet weld

3D viewer

The 3D viewer shows the column, utilizza combinazioni di carico fattorizzate in ASCE, grout, calcestruzzo, anchors and welds. Dimensions are shown on the Geometry tab (concrete and base plate) and the Anchors tab (ancore). Load arrows are shown on the Column Loads tab.

SkyCiv Base Plate Design 3D viewer, Welds tab, showing a column base plate model with info panel, plan view and view cube

Viewer buttons

The buttons on the right edge of the viewer, from top to bottom:

Pulsante Descrizione
Ruotare Left-drag rotates the model. This is the default mode.
Padella Left-drag pans the model.
Zoom Left-drag zooms the model.
Spettacolo / Hide dimensions Shows or hides the dimension lines.
Fit model to view Centres and zooms on the model, keeping the current view angle.
Switch to orthographic / perspective view Toggles the camera type. Perspective is the default.
Download the 3D model (IFC) Downloads the model as an IFC4 file.
Download an image of the model Downloads a PNG of the current view on a white background, with the info panel.

In all modes, right-drag pans and the mouse wheel zooms.

View cube

The view cube in the bottom-left corner has the faces TOP, BOT, FRONT, BACK, LEFT and RIGHT. Click a face or a corner to turn the camera to that view.

Plan view

The small plan in the top-right corner shows the base plate, colonna, anchors and welds from above, with the Z (orizzontale) e Y (verticale) assi. It updates with the inputs.

Bottom bar

The bar under the viewer shows:

  • Tutorial, which starts the guided tour
  • What’s New, which opens the release notes
  • the version number, which opens the changelog
  • the file name, which saves the file when clicked

Scheda Risultati

Apri il Risultati tab to run the design. Before the design runs, the inputs, the design layout and the detailing checks are validated.

  • If the validation passes, the design runs. Until the first successful run, opening the Results tab runs the design automatically.
  • If the validation fails, the design does not run. A Design Checks Unavailable message lists each problem with a Click here to modify link to the input. If there are only warnings, Click here to proceed anyway runs the design. If a detailing check fails, the message links to Impostazioni > Dettagli.
  • After a run, if you change an input, the results are blurred and a I risultati necessitano di aggiornamento message is shown. Fai clic su Esegui controlli di progettazione to run the design again.

SkyCiv base plate design software Results tab: AISC design passed, detailing and design check summaries, 3Modello D.

Run banner

The banner at the top shows the outcome:

Banner Senso
Progettazione completata & Passato All checks passed. The calculation report and the detail drawing are available.
Progettazione completata & Fallito One or more checks failed. The calculation report is available. The detail drawing is available only after all checks pass.

The banner has the Visualizza il disegno dettagliato e Visualizza il rapporto di calcolo pulsanti.

Detailing Checks Summary

Each detailing check that is turned on in Impostazioni > Dettagli is listed with a pass or fail icon and its minimum, maximum and actual values. Some checks have an information icon with the code clause. The last row is Design Layout, which shows No conflicts detected or lists each conflict with a link to the input.

For a fixed support, the design layout check requires that:

  • at least one combination has a moment
  • no combination has both Mz e My
  • each tension zone has only one row of anchors

Riepilogo dei controlli di progettazione

Each design check is listed with:

  • a status icon: a green tick (passaggio), a red cross (fallire) or a grey minus (skipped by a Design setting)
  • the check name
  • the demand and capacity
  • LC n: the governing load combination
  • the utilization ratio: green when the ratio is less than 1.0, red when it is 1.0 o più

Each row shows the result of the governing load combination, which is the one with the highest ratio. A check that does not apply to any combination shows N / A. A check skipped by a Design setting shows "-" and the note This design check is excluded from the report based on user settings.

The step-by-step calculations for each check are in the calculation report.

If the server returns an error for the design, un carico Design Check Requires Attention message lists the issues.

Calculation report

Fai clic su Visualizza il rapporto di calcolo in the run banner and choose a report:

rapporto Contenuto
Rapporto completo Step-by-step calculations with diagrams
Rapporto Lite Calcoli passo passo, no diagrams
Relazione di sintesi Check results only, no calculation steps

The report opens in a window with Apri in una nuova scheda, ScaricaHTML e Scarica PDF. The PDF is named after the file name in the bottom bar.

Base Plate Design run banner with the View Calculation Report menu open, listing Full Report, Lite Report and Summary Report

SkyCiv Base Plate Design report window with AISC 360-22 e ACI 318-19 calcoli, download and open buttons highlighted.

Detail drawing

Fai clic su Visualizza il disegno dettagliato in the run banner to open the Structural Drawing finestra. The button is available after all checks pass. In the free version, the drawing preview always opens and shows a watermark.

Structural Drawing window in SkyCiv Base Plate Design: Piano, elevazione, anchor detail preview, zoom bar, Drawing Settings, export buttons

The drawing sheet has these views:

  1. Plan view
  2. Vista dall'alto
  3. Typical anchor detail
  4. 3D view

It also has the drawing notes, un programma di carico e un cartiglio.

The preview on the left is a quick sketch. Use the zoom bar in the top-right corner of the preview to zoom in or out or to fit the full page. You can also drag to pan, use the mouse wheel to zoom, and double-click to fit.

Drawing Settings a destra:

Sezione Ingressi
Impostazione pagina Page Size (A4 to A0, Letter, Legale, Tabloid), Drawing Scale, Detail Scale, Annotation Scale. Per impostazione predefinita, the page size is the smallest A size that fits the drawing.
Mark-ups Labels for the Colonna, Piastra di base, Ancorare, Calcestruzzo e, for plate endings, Embedded Plate. Filled from the design.
Drawing Notes The notes printed on the sheet.
Title Block Information Cliente, Nome del progetto, ID progetto, Azienda, Drawing Title e progettista. Filled from the Details tab.

Fai clic su Update Preview to apply the settings to the preview. The settings are not saved and are reset each time you open the window.

Esporta in PDF

Esporta in PDF creates a PDF of the drawing and downloads it.

Esporta in CloudCAD

Esporta in CloudCAD opens the drawing in SkyCiv CloudCAD, where you can edit it further.

Free version

The free version of SkyCiv Base Plate Design has these limits for an AISC fixed design:

Area Limite
Start window File Manager e Caricare un file non sono disponibili.
Geometria Column Shape, Banca dati, Materiale in acciaio, Base Plate Steel Material and Concrete Compressive Strength cannot be changed from the template values. The profile can be changed within the template database. Custom materials are not available.
Ancore Materiale in acciaio, Filettature nel piano di taglio, Ending and Failure Mode cannot be changed. The group columns of the Tension and Shear Anchors Summary tables are hidden.
saldature Weld Type and Weld Electrode Classification cannot be changed.
Column Loads One load combination only. Rows cannot be added or removed, but the values can be edited.
Impostazioni The detailing checks cannot be turned off. The factors and design settings can be edited.
Risultati The banner shows Progettazione completata, without Passed or Failed. Richiesta, capacity and ratio are hidden for the anchor, rottura concreta, pryout, concrete bearing, base plate and interaction checks. Weld checks show their values.
Calculation report Not available.
Detail drawing The preview has a watermark. Page Setup and Drawing Notes cannot be changed. Export to PDF and Export to CloudCAD are not available.
3D viewer The screenshot and IFC buttons are not available. The base plate shows the SkyCiv logo.

Locked items are marked PRO. Selecting one opens the upgrade prompt.

Calculation report and detail drawing generated by SkyCiv Base Plate Design

Come possiamo aiutare?

×

Aggiornato novembre 25, 2026

Ha ancora bisogno di aiuto? Ci contatti

Vai all'inizio