ΔΩΡΕΑΝ ΕΡΓΑΛΕΙΑ
Λογισμικό σχεδίασης ξύλινων τοίχων
Design segmented wood shear walls to NDS® and SDPWS fast, accurately, and code compliant with this free version of our wood shear wall design software.
The software allows you to design wood shear walls split into full height panels between openings. The timber shear wall segments share the storey shear based on their stiffness and common wall displacement, and each is then checked against six utility ratios, including wall shear, hold down tension, column tension, column compression, sill crushing, and drift.
A ratio of exactly 0 for column compression or sill crushing means the chord is in net uplift at that load, so the check does not apply. It does not mean the check is comfortably satisfied.
ο Λογισμικό σχεδίασης ξύλινων τοίχων is part of the SkyCiv Quick Design Module. Try the tool out for free below:
About the NDS® Wood Shear Wall Design Software
Wood Shear Wall Design Software Hypotheses
- The software only supports the design of timber shear walls using the segmented method; perforated shear walls are not covered.
- Segments are defined in the openings table and are numbered left to right.
- Chords are braced out of plane by the sheathing and the stud wall, so column slenderness uses the full stud depth rather than the built-up post's least dimension.
- The size factor C_F is looked up on a single ply, not on the full built-up chord.
- Nails are considered as common nails, at the lengths SDPWS Table A1 tabulates.
- The shear-distribution provisions of SDPWS 4.3.5.5 are limited to a line whose walls share the same sheathing materials. This calculator does not use that exception: it solves 4.3.5.5.1 itself, giving every segment the same calculated deflection, which is a rational analysis that holds whether or not the assemblies match.
- The full tributary width of the wall resists uplift in the tension post, but only half the stud spacing amplifies compression in the compression post.
Wood Shear Wall Calculator Limitations
- Unblocked walls are limited to 16ft in length.
- Simultaneous uplift and shear is currently not validated.
- When a wall has double sheathing on both sides, the software considers that both are identical (same grade, πάχος, and nailing).
- Anchoring of the sill plate is not included. Uplift and linear shear forces are not transferred to the substrate. Please see the output for the governing magnitude for each segment.
- Sill crushing is unbounded above F_cp. Nothing caps the bearing overstress ratio, so a badly overloaded post produces a very large deflection.
- Framing width is not modelled. Every stud is a single 2x, and only the chords stack plies, so where SDPWS 4.3.7.1(5) calls for 3 in nominal framing and staggered nailing at adjoining panel edges, the software will raise a warning.
- Header and trimmer/king stud design is excluded. Only the wall panels between openings are designed here; the lintel spanning an opening and the studs framing it are not sized.
- Column compression is checked for the lateral load combination only.
Wood Shear Wall Software Design Checks
The wood shear wall software completes the following design checks, where each check is demand divided by capacity, evaluated per segment in every direction solved.
- Ελεγχος 1: Wall Shear. Determined against the SDPWS Table 4.3A nominal capacity for that segment's own sheathing assembly, modified by the following parameters:
- Ω_D (2.0 άνεμος, 2.8 σεισμικός)
- φ_aspect, the aspect ratio factor for slim shear walls (1.25 - 0.125 h/b above 2:1).
- φ_framing, the specific gravity adjustment 1 - (0.5 - σολ) for framing lighter than Douglas-Fir-Larch or Southern Pine.
- φ_pos, ένα 0.92 reduction when the hold-down carrying tension is on the inside face of the end post (Σημείωση 10). The note grants this to assemblies with 10d common nails only.
- C_ub for unblocked shear walls.
- Ελεγχος 2: Hold-down Tension. Determined against the selected model's rated capacity, rescaled from the specific gravity the catalogue tabulates it at (0.43 SPF/HF, 0.50 DF/SP) to the framing species chosen.
- Ελεγχος 3: Column Tension. In the tension chord, against F_t'.
- Ελεγχος 4: Column Compression. In the compression chord, against F_c'.
- Ελεγχος 5: Sill Crushing. The compression chord bearing across the grain into the sill plate, against F_cp' with the bearing area factor C_b. This is also the term driving the nonlinear part of the deflection, so failing it and a large drift tend to arrive together.
- Ελεγχος 6: Drift. The service displacement of the wall line against the selected allowable storey drift. It is a property of the line rather than of any one panel, so the same value repeats across every segment of a direction.
As stated earlier, a ratio of exactly 0 on column compression or sill crushing means the chord is in net uplift at that load, so the check does not apply. It does not mean the check is comfortably satisfied.
Selecting the Wood Shear Wall Drift Limit
- Ανεμος: H/400 (Προκαθορισμένο), H/500, H/600.
- Σεισμικός: H/40, H/50 (Προκαθορισμένο), H/66.7, H/100, H/150.
Wood Shear Wall Software References
- Εθνικές Προδιαγραφές Σχεδιασμού για Ξύλινες Κατασκευές 2018
- NDS® Supplement: Design Values for Wood Construction 2018
- Special Design Provisions for Wind and Seismic 2021
- ASCE 7: Minimum Design Loads
- ASTM D143: Standard Test Methods for Small Clear Specimens of Timber
Λογισμικό σχεδίασης SkyCiv
Το SkyCiv προσφέρει ένα ευρύ φάσμα Λογισμικό Δομικής Ανάλυσης και Μηχανικής Σχεδιασμού Cloud, συμπεριλαμβανομένου:
- SkyCiv Quick Design
- Υπολογιστής χωρητικότητας φορτίου Steel I Beam
- AS / NZS 1664 Σχεδιασμός αλουμινίου
- AS / NZS 4600 Σχεδιασμός τεγίδων
- ΟΠΩΣ ΚΑΙ 3600 Σχεδιασμός διατμητικού τοίχου από σκυρόδεμα
- ΟΠΩΣ ΚΑΙ 2870 Οικιστική πλάκα σε σχέδιο βαθμού
- AS / NZS 1576 Σχεδιασμός σκαλωσιάς
- ΟΠΩΣ ΚΑΙ 4055 Υπολογιστής φορτίου ανέμου
- ΟΠΩΣ ΚΑΙ 4100 Υπολογιστής ομάδας Bolt
- ΟΠΩΣ ΚΑΙ 4600 Αριθμομηχανή Σχεδιασμού Ψυχρής Μορφοποίησης Χάλυβα
Ως μια συνεχώς εξελισσόμενη εταιρεία τεχνολογίας, we're committed to innovating and challenging existing workflows to save engineers time in their work processes and designs.
ΤΙΜΗ
Πρόσβαση στο SkyCiv Quick Design
Διαισθητική διασύνδεση
Μας είναι εύκολο να μάθουμε, ισχυρό στη χρήση, Η διαισθητική διεπαφή σάς επιτρέπει να έχετε γρήγορη πρόσβαση σε όλες τις λειτουργίες που χρειάζεστε. Γεμάτο με έξυπνες λειτουργίες όπως το εργαλείο στυλό, Επανάληψη / Καθρέφτης, και Μαζική επεξεργασία. Το περιεχόμενό σας πηγαίνει εδώ
Ολοκληρωμένη Υποστήριξη Κώδικα Σχεδιασμού
Το λογισμικό μας υποστηρίζει μια ολοκληρωμένη σειρά από χάλυβα, ξύλο, και συγκεκριμένοι κώδικες σχεδιασμού συμπεριλαμβανομένου του AISC, ΣΕ, AISI, NDS, ΟΠΩΣ ΚΑΙ, και CSA.
Τεχνολογία API
Το SkyCiv είναι μια προσαρμοσμένη λύση που διαθέτει απρόσκοπτες ενσωματώσεις, εύκολες υλοποιήσεις, αυτοματοποιημένες αναφορές και επεκτάσιμη σχεδίαση και αρχιτεκτονική.
24/7 Υποστήριξη πελατών
Το SkyCiv είναι μια προσαρμοσμένη λύση που διαθέτει απρόσκοπτες ενσωματώσεις, εύκολες υλοποιήσεις, αυτοματοποιημένες αναφορές και επεκτάσιμη σχεδίαση και αρχιτεκτονική.