This page explains how SkyCiv Foundation designs a combined footing to ACI 318-19: 土壤承载力, 单向剪切, punching shear and flexure, with the equations used and the results shown in the software and the calculation report, followed by the other design checks (提升, 倾覆, 滑行, 负载转移, development length and detailing). Flexure is described with the default Strip average method, 和 巅峰木臂法 is summarized for comparison.
一个 组合基础 is a single footing supporting two columns. It is commonly used when the columns are too close to each other, or a column is too close to a property line, for two separate isolated footings. SkyCiv Foundation meshes the footing into plate elements supported on the soil (modeled with the subgrade modulus) and analyzes it with finite element analysis (丑陋). The soil pressures, shears and moments used in the design checks below come from these FEA results. To design to the 2019 版, 选择 美国混凝土协会 作为设计规范和 ACI 318 (2019) 作为启动新文件时的版本, 然后选择 联合立足. The same checks to the 2014 edition are described in 根据ACI的组合基础设计 318-14.

The example shown on this page is a 3000 × 1500 × 500 mm combined footing with two 300 × 300 mm columns placed 250 mm from the ends of the footing (X-edge Distance), #5 bars at 200 mm in both directions at the top and bottom, 和一个 75 mm cover. 柱 1 carries a dead load of 200 kN and a live load of 100 千牛, 和列 2 a dead load of 250 kN and a live load of 120 千牛. The x-direction is the direction joining the two columns.
Design Settings for ACI 318-19
The methods used for the checks are set in Edit Design Settings (Details tab). 对于ACI 318-19, 的 力矩需求计算 提供 Strip average method (默认) 和 巅峰木臂法. The settings also hold the 执行单向剪切检查 toggle and the 冲剪边缘系数 (0.5 默认), as well as the switches of the load transfer and development length checks.

Combined Footing Design Checks to ACI 318-19
Dimension Requirements and Soil Bearing
To size a combined footing, 服务 (未分解的) loads such as Dead (d), 生活 (大号), 风 (w ^) and Seismic (Ë) are combined with the service load combinations. The governing combination is the design load, and the base area is proportioned so that the allowable soil pressure is not exceeded (ACI 318-19, 截面 13.3.1.1):
[math] q_{a} = \frac{P1_{n} + P2_{n}}{A} \quad \text{(Eq. 1)} [math]
q一个 = 允许土壤压力
P1ñ, P2ñ = Unfactored loads at Column 1 (剩下) 和列 2 (对)
设计独立基础所需计算的示例演练
Solving Equation 1 for the area gives a first estimate of the footing dimensions:
[math] A = \frac{P1_{n} + P2_{n}}{q_{a}} \quad \text{(Eq. 1a)} [math]
SkyCiv Foundation does not size the footing from Equation 1a: the dimensions are inputs (几何选项卡), and the software checks them. 该 土壤承载力 ratio is the maximum soil pressure from the FEA results of the service load combinations (信封), which includes the effect of the column moments and of the eccentricity of the loads, divided by the allowable soil bearing capacity entered in the Soil tab:
[math] \text{Utility Ratio} = \frac{q_{sls,max}}{q_{a}} \quad \text{(Eq. 2)} [math]
In the example, the maximum service soil pressure is 224.1 千帕, under Column 2, which carries the larger load, and the Soil Bearing ratio is 0.448. The soil pressure contour and the ratio of every check are shown in the 结果 标签:

单向剪切
单向剪切极限状态, 也称为梁剪, treats the footing like a wide beam that may fail in shear along a critical section located at a distance "d" 从柱子的表面. It is checked when 执行单向剪切检查 is enabled in the design settings (默认开启).
该 单向剪切需求 要么 \( V_{u} \) is taken from the strip average shear diagrams of the FEA (ultimate load combinations): the shear forces of the plate elements are summed across the width of the footing, and the diagram is read at the critical sections, located at the effective depth of the bottom bars in that direction from each column face (or at the edge of the footing when that distance falls outside it). The largest absolute shear at these sections is the demand.
- Along x (the direction joining the columns), one diagram covers the whole footing, with the critical sections on both sides of both columns.
- Along z, each column has its own diagram, through that column.
The diagrams can be viewed in the 结果 tab by opening 图表 and choosing 单向剪切 在里面 图表 列表. In the example, the critical sections along x are 417 毫米 (the effective depth of the bottom x-bars) from the inner faces of the columns, and the demand is 158.70 千牛, next to Column 2:

数字 1. Critical sections and shear diagram of one-way shear along x (结果, 图表按钮)
该 设计独立基础所需计算的示例演练 要么 \( \phi V_{c} \) is calculated with Equation 3 (桌子 22.5.5.1(C), for members without shear reinforcement). The size effect factor \( \lambda_{s} \) is neglected for footings, as permitted by 截面 13.2.6.2.
[math] \phi V_{c} = \phi_{\text{shear}} \times 8 \lambda \left( \rho_{w} \right)^{1/3} \sqrt{f’_{c}} \times b_{w} \times d \quad \text{(Eq. 3, Table 22.5.5.1(c), Imperial)} [math]
要么
[math] \phi V_{c} = \phi_{\text{shear}} \times 0.66 \lambda \left( \rho_{w} \right)^{1/3} \sqrt{f’_{c}} \times b_{w} \times d \quad \text{(Eq. 3, Table 22.5.5.1(c), Metric)} [math]
[math] \rho_{w} = \frac{n \times A_{b}}{L \times d} [math]
ϕ剪力 = 剪切强度折减系数, 0.75 (桌子 21.2.1)
λ = 轻质混凝土的改性系数
rw = Ratio of the bottom bars in the direction checked
ñ, 一个b = Number and area of these bars, across the footing dimension L perpendicular to them
F’C = 指定混凝土强度 (压力, 兆帕)
bw = Width resisting the shear (在, 毫米)
d = Effective depth of the bottom bars in the direction checked (在, 毫米)
Along x, \( b_{w} \) is the full width of the footing (its dimension along z). Along z, the footing is divided into two design strips at the midpoint between the two column centres, and each column’s shear is checked against the capacity of its own strip, 与 \( b_{w} \) equal to the strip width. In the example, both strips are 1500 毫米宽.
The calculation report shows the shear diagram of each direction, followed by the demand, the capacity and the ratio. Along x, \( \phi V_{c} \) = 192.9 kN and the ratio is 158.7/192.9 = 0.823:

设计独立基础所需计算的示例演练 318-19:
[math] V_{u} \leq \phi V_{c} \quad \text{(Eq. 4, Section 7.5.1.1(b))} [math]
SkyCiv Foundation, 符合方程 4, calculates the one-way shear utility ratio by taking Shear Demand over Shear Capacity, along x and for each column along z. The largest ratio is listed as 这些比率表示每个单独的极限状态的经验/能力 在设计检查摘要中.
[math] \text{Utility Ratio} = \frac{\text{Shear Demand}}{\text{Shear Capacity}} \quad \text{(Eq. 5)} [math]
双向剪切 (冲剪)
The two-way shear limit state, 也称为冲剪, has its critical section at a distance "d/2" 从柱子的表面, 围绕柱的周边 (截面 22.6.4.1). 它的长度就是临界周长 \( b_{o} \). The check is done for each column. The critical perimeters can be viewed in the 结果 tab by opening 图表 and choosing 冲剪 在里面 图表 列表:

数字 2. Critical perimeters of two-way shear (结果, 图表按钮)
The effective depth d is the average of the effective depths of the bottom bars in both directions (409 mm in the example). 当柱面比基脚边缘更靠近基脚边缘时 冲剪边缘系数 由使用公式计算的最小值控制, 该侧的周长延伸至基础边缘,不计入在内 \( b_{o} \). 然后该柱被分类为室内, 边柱或角柱, 其中设置 \( \alpha_{s} \) = 40, 30 要么 20 (截面 22.6.5.3). 如果柱子靠近两个相对的边缘, the punching shear check is skipped for that column, 当单向剪切力控制时. A round column is taken as an equivalent square column with sides equal to its diameter. In the example, both columns are interior columns, 与 \( b_{o} \) = 4 × 709 = 2836 毫米.
该 双向剪切需求 使用基于网格的方法在临界周长处计算, 从基础的有限元分析. 临界周长内土压力产生的向上力, \( F_{q} \), 是该区域中网格元素的力的总和 (the average pressure on each element times its area inside the perimeter, listed in a table of the report), 并从因子列载荷中减去它. 最大剪应力 \( v_{u} \) 临界周长还包括由偏心剪力传递的不平衡力矩 (ACI 421.1R-20):
[math] v_{u} = \frac{P_{u} – F_{q}}{b_{o} \times d} + \frac{\gamma_{v,x} \times M_{u,x} \times c_{x}}{J_{c,x}} – \frac{\gamma_{v,z} \times M_{u,z} \times c_{z}}{J_{c,z}} \quad \text{(Eq. 6)} [math]
[math] \gamma_{v} = 1 – \frac{1}{1 + \frac{2}{3}\sqrt{b_{1}/b_{2}}} \quad \text{(Eq. 7)} [math]
Pü = 因式分解的柱负载
Fq = Resultant of the factored soil pressure inside the critical perimeter, summed over the FEA mesh elements
Cv = 偏心剪切传递的不平衡力矩的分数
mü = 不平衡力矩: 柱矩, 加上柱剪力乘以柱高和基础厚度, minus the column load times the offset of the centroid of the critical section (edge and corner columns)
b1, b2 = Dimensions of the critical section perpendicular and parallel to the direction considered
C, ĴC = 到考虑点的距离和临界截面的极惯性矩
For edge and corner columns, \( \gamma_{v} \) and the stresses are calculated following ACI 421.1R-20. The maximum stress around the critical section is taken as the demand.
该 剪切能力 是冲切剪切应力 \( \phi v_{c} \), 由方程的最小值控制 8, 9 和 10 每 截面 22.6.5.2. Unlike ACI 318-14, 的 2019 edition includes the size effect factor \( \lambda_{s} \) (截面 22.5.5.1.3), which reduces the capacity of footings with an effective depth over 10 在 (250 毫米). In the example, \( \lambda_{s} \) = 0.871 for d = 409 毫米.
[math] \lambda_{s} = \min \left( 1, \sqrt{\frac{2}{1 + d/10}} \right) \quad \text{(Imperial)} \qquad \lambda_{s} = \min \left( 1, \sqrt{\frac{2}{1 + 0.004\,d}} \right) \quad \text{(Metric)} [math]
[math] v_{c,a} = 4 \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 8, Section 22.6.5.2(a), Imperial)} [math]
[math] v_{c,b} = \left( 2 + \frac{4}{\beta} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 9, Section 22.6.5.2(b), Imperial)} [math]
[math] v_{c,c} = \left( 2 + \frac{\alpha_{s} \times d}{b_{o}} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 10, Section 22.6.5.2(c), Imperial)} [math]
要么
[math] v_{c,a} = 0.33 \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 8, Section 22.6.5.2(a), Metric)} [math]
[math] v_{c,b} = \left( 0.17 + \frac{0.33}{\beta} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 9, Section 22.6.5.2(b), Metric)} [math]
[math] v_{c,c} = \left( 0.17 + \frac{0.083 \times \alpha_{s} \times d}{b_{o}} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 10, Section 22.6.5.2(c), Metric)} [math]
[math] \phi v_{c} = \phi_{\text{shear}} \times \min \left( v_{c,a}, v_{c,b}, v_{c,c} \right) [math]
注意: β为柱长边与短边之比 (1.0 对于圆柱), 和 \( \alpha_{s} \) 由部分给出 22.6.5.3. ϕ剪力 = 0.75 (桌子 21.2.1).
λs = Size effect modification factor
λ = 轻质混凝土的改性系数
F’C = 指定混凝土强度 (压力, 兆帕)
D =有效的深度, 两个方向底部钢筋有效深度的平均值 (在, 毫米)
b的 = 临界周长 (在, 毫米)
The calculation report shows, for each column, the plan of the critical shear area, the soil pressure force \( F_{q} \), the stresses around the perimeter, and the capacity. p = p 1 of the example, \( v_{u} \) = 0.261 MPa and \( \phi v_{c} \) = 0.980 兆帕:

设计独立基础所需计算的示例演练 318-19:
[math] v_{u} \leq \phi v_{c} \quad \text{(Eq. 11, Section 7.5.1.1(b))} [math]
SkyCiv Foundation, 符合方程 11, calculates the two-way shear utility ratio of each column by taking Shear Demand over Shear Capacity, 两者都是压力. The larger ratio of the two columns is listed as 冲剪 在设计检查摘要中 (0.318 in the example, from Column 2).
[math] \text{Utility Ratio} = \frac{\text{Shear Demand}}{\text{Shear Capacity}} \quad \text{(Eq. 12)} [math]
受弯
SkyCiv Foundation checks the top and bottom reinforcement in both directions against the moments of the whole footing from the FEA, rather than at a single critical section. In a combined footing, the top bars along x resist the hogging moment between the columns, and the bottom bars resist the sagging moments under the columns and in the transverse direction.
Moment Demand with the Strip Average Method
随着 Strip average method (默认值 力矩需求计算), the footing is treated like a wide beam in each direction: the Wood-Armer moments of the plate elements are summed across the width of the footing, which gives the total moment carried by that width at each section. This is done for the top and bottom layers, 沿 x 和沿 z, 在极限荷载组合下 (信封).
- Along x, the strip covers the full width of the footing, and one moment diagram covers both columns.
- Along z, the footing is divided into two design strips at the midpoint between the column centres, and each column has its own diagram.
- Bottom layer: \( M_{u} \) is the largest strip moment at the column faces.
- Top layer: \( M_{u} \) is the largest hogging (消极的) strip moment anywhere along the strip.
The moment diagrams can be viewed in the 结果 tab by opening 图表, choosing 时刻 在里面 图表 列表, and picking the 层 和 方向. In the example, the top layer along x has a maximum hogging moment of 154.65 千牛·米, near midway between the columns:

数字 3. Strip average moment diagram, top layer along x (结果, 图表按钮)
The calculation report shows the same diagram for each layer and direction, with a table of the maximum moment, its coordinates and the governing load combination, followed by the utility ratio:

Peak Wood-Armer Method
随着 巅峰木臂法, \( M_{u} \) is instead the maximum Wood-Armer moment per unit width found anywhere over the footing, 用于两个方向的顶层和底层, and the capacity is calculated per unit width (12 在或 1000 毫米). Because it uses the peak moment rather than the moment spread over the width, it is usually more conservative. The Wood-Armer moments can be viewed in the 结果 tab with the Wood Armer 纽扣, by picking the 案件, 层 和 方向 在里面 View Options. In the example, the peak top moment along x is 105.17 千牛·米/米, while the strip average moment of 154.65 kN-m over the 1.5 m width of the footing is 103.1 千牛·米/米. This method is described in 根据ACI的组合基础设计 318-14.

抗弯能力
With the strip average method, 的 抗弯能力 要么 \( \phi M_{n} \) is calculated for the width of the strip, with the bars of the layer across that width (along z, the share of the bars in each strip, in proportion to its width), 使用方程式 13:
[math] \phi M_{n} = \phi_{\text{flexure}} \times A_{s} \times f_{y} \times \left( d – \frac{a}{2} \right) \quad \text{(Eq. 13)} [math]
[math] a = \frac{A_{s} \times f_{y}}{0.85 \times f’_{c} \times b} [math]
ϕ弯曲 = Flexural strength reduction factor (桌子 21.2.2)
一个s = Area of the tension bars of the layer across the strip width (在2, 毫米2)
F和 = Reinforcement strength (压力, 兆帕)
d = Distance from the extreme compression fiber to the centroid of the tension reinforcement (在, 毫米)
a = Depth of the equivalent rectangular stress block (在, 毫米)
b = Strip width: the full width of the footing along x, the strip of each column along z (在, 毫米)
The strength reduction factor depends on the net tensile strain \( \varepsilon_{t} \), found from the neutral axis depth \( c = a/\beta_{1} \) (b1 从表 22.2.2.4.3) and a concrete strain of 0.003. ACI 318-19 compares it with the yield strain of the reinforcement \( \varepsilon_{ty} = f_{y}/E_{s} \):
[math] \phi_{\text{flexure}} = 0.65 + 0.25 \times \frac{\varepsilon_{t} – \varepsilon_{ty}}{0.003} \quad \text{(Table 21.2.2)} [math]
with ϕ = 0.90 什么时候 \( \varepsilon_{t} \geq \varepsilon_{ty} + 0.003 \) (张力控制) and ϕ = 0.65 什么时候 \( \varepsilon_{t} \leq \varepsilon_{ty} \) (压缩控制). The report shows a warning when the section is not tension-controlled. When the tension steel ratio exceeds the balanced ratio, the section is checked as doubly reinforced, with the other layer as compression steel.
In the example, 的 8 top bars along x (1608.5 平方毫米) with d = 417 mm give \( \phi M_{n} \) = 163.25 千牛·米, and the top layer ratio along x is 154.65/163.25 = 0.947.
The provided reinforcement of each layer, 在每个方向, is also compared to the minimum area of 0.0018 一个G (截面 8.6.1.1), where AG is the gross area of the footing section perpendicular to the bars.
= 平行于 x 轴的基础尺寸 318-19:
[math] M_{u} \leq \phi M_{n} \quad \text{(Eq. 14, Section 7.5.1.1(a))} [math]
SkyCiv Foundation, 符合方程 14, calculates the flexural utility ratio by taking Flexural Demand over Flexural Capacity, for the top and bottom layers along x and for each strip along z. 该 受弯 ratio in the Design Checks Summary is the largest of the top, 底部配筋率和最小配筋率 (0.947 in the example).
[math] \text{Utility Ratio} = \frac{\text{Flexure Demand}}{\text{Flexure Capacity}} \quad \text{(Eq. 15)} [math]
Other Design Checks
Besides the checks above, the calculation report of a combined footing designed to ACI 318-19 includes the stability checks, the load transfer at the column bases, the development length of the bars and a detailing check. Each one gives a utilization ratio in the 设计检查摘要 的 结果 标签. The largest ratio governs the design, and the footing fails when it is greater than 1.0. A check that does not apply to the loads (for example sliding without horizontal loads) is shown with a dash.
上拔
The uplift check compares the upward forces with the forces holding the footing down, 仅考虑轴向载荷: the column loads, the self-weights of the columns, footing and soil, and the buoyant force. 当没有使用荷载组合产生抬升时, 不需要支票.
倾覆
Overturning is checked by summing the moments of all the forces about the toe and the heel of the footing, 在每个方向, for all the service load combinations. 执政者 (smallest) 安全系数, 稳定力矩大于倾覆力矩, 与 倾覆 的安全系数 设计因素 tab of the Loads. If the loads produce no overturning moment, 不需要支票.
滑移
Sliding is checked in each direction by dividing the horizontal resisting forces by the horizontal force applied to the footing, with both taken from the same service load combination (the one with the lowest factor of safety). The resisting forces are the friction between the footing base and the soil (没有净抬升), the passive soil pressure and the cohesion of the soil. The factor of safety is compared with the 滑移 的安全系数 设计因素 标签. If no horizontal force acts on the footing, 不需要支票.
负载转移
该 负载转移 check verifies the bearing of each column on the footing (截面 22.8.3.2). The factored axial load of the column is compared with the design bearing strength, with ϕ = 0.65:
[math] \phi B_{n} = \min \left( \phi \times 0.85 f’_{c} A_{1} \sqrt{\frac{A_{2}}{A_{1}}}, \; \phi \times 2 \times 0.85 f’_{c} A_{1} \right) \quad \text{(Eq. 16)} [math]
一个1 = Loaded area (the column area)
一个2 = Base of the frustum with 1 垂直于 2 horizontal side slopes under the column, wholly within the footing: its projection beyond the column is limited by the nearest footing edge and by 2 times the footing thickness
The larger ratio of the two columns is listed as 负载转移 (0.560 in the example). The report also compares the area of the dowel bars of each column with the minimum of 0.005 times the column area (截面 16.3.4.1).
开发长度
该 开发长度 check covers the column dowel bars and the flexural bars of the footing:
- Column dowel bars: the compression development length (截面 25.4.9), plus the bend of the dowel, must fit in the footing thickness.
- Flexural bars: at each column face, the force in the bars must be developed on each side of the section (截面 13.2.8.2). The tension development length of straight bars (截面 25.4.2) or hooked bars (截面 25.4.3, depending on the bar ends chosen in the Reinforcement tab) is compared with the anchorage length available from the column face to the end of the bar.
The checks can be turned on or off in the design settings (Perform dowel bars check, Perform top bars check 和 Perform bottom bars check). In the example, the Development Length ratio of 1.231 comes from the bottom bars along x at the outer face of Column 1: 只要 175 mm is available (的 250 mm X-edge Distance minus the 75 mm cover), while the hooked bars need 215.35 毫米. Increasing the X-edge Distance of the columns gives the bars the anchorage they need. The development length checks are explained in more detail in the ACI 318 (2019) 锚固长度验算指南, written for isolated footings.
细部
该 细部 check verifies that the footing thickness can hold the hooked ends of the top and bottom bars (90° or 180° hooks), with their bend and extension and the top and bottom covers.
产品开发人员
理学士 (民用), 理学硕士 (民用)
领英
参考资料
- 结构混凝土的建筑规范要求 (ACI 318-19) 及评论 (ACI 318R-19). 美国混凝土协会, 2019.
- ACI委员会 421. 板抗剪加固指南 (ACI 421.1R-20). 美国混凝土协会, 2020.