FREE MOMENT CONNECTION CALCULATOR
SkyCiv Moment Connection Calculator
This moment connection calculator checks flange plate, extended end plate and flush end plate details against AISC 360-16, είτε σε ASD είτε σε LRFD.
These joints transfer bending between members rather than shear alone. The aim is to behave as closely as possible to a fixed joint, rigid in every direction, which is why these are also called rigid connections.
Περιεχόμενα
Τι είναι μια σύνδεση στιγμής?
A joint that transfers bending moment between a column and a beam, or between any two members. If the beam carries internal moment, the connection has to be able to transmit the load that moment produces.
The objective is to get as close as possible to a fixed joint, ο κωδικός σταθερότητας FFFFFF, meaning rigid in all translational and rotational directions. That is where the alternative name comes from: rigid connections.
How Does It Differ From a Shear Connection?
Διατμητικές συνδέσεις depend mostly on the web of a section. A rigid joint adds to that by strengthening the connectivity of the flanges, using plate stiffeners, welds or other fixtures that increase rigidity between the members.
The result is a joint that can carry far more moment. The cost is material, and it is not a small difference: the same members cost significantly more to join this way than with a shear connection.
That economics is worth stating plainly, because it drives real design decisions. A typical structure has only one or two unique moment connections, precisely to keep that cost contained. They are used where the frame needs them, not by default.
Types of Moment Connection
Three arrangements cover most of what gets built, and the calculator handles all three.
Πλάκα φλάντζας
Plates join the beam to the column, bolted or welded or both, to form a rigid fixture. In the arrangement below, two plates are bolted to the flanges of the beam to connect it to the column. As the beam bends, that action passes into the connected member.

Extended End Plate
A rigid plate welded to the end of the beam, running past one or both flanges. That extension is doing something specific: it creates leverage, so extra rows of high-strength bolts can sit outside the beam profile.
The larger moment arm is what raises stiffness and capacity, by resisting the tension and compression forces more efficiently. It suits high-stress seismic work and heavy structural frames.

Flush End Plate
A rigid plate welded to the beam end and bolted to the face of the column, but stopping at the flanges rather than running past them.
Tension and compression go into the column mainly through the high-strength bolts packed between the beam’s flanges. Less capacity than an extended plate, and in exchange a compact profile that lines up with the beam’s outer edges.

Πώς να χρησιμοποιήσετε την αριθμομηχανή σύνδεσης στιγμής
- Choose the connection type: πλάκα φλάντζας, extended end plate or flush end plate.
- Set the members: the beam and column sections being joined.
- Define the plate and bolt details: μεγέθη πλάκας, and the bolt grade and arrangement.
- Enter the design actions: the bending moment and the shear at the joint.
- Επιλέξτε τη μέθοδο σχεδιασμού: ASD ή LRFD, στην AISC 360-16.
Υπολογίζω, and the capacities come back with utility ratios so you can see which component is closest to its limit.
Γιατί να επιλέξετε το SkyCiv's Moment Connection Calculator?
Because these joints are expensive, the useful question is rarely whether one arrangement works. It is which of the three is the cheapest that still works, and that means checking all of them.
Running the checks to AISC 360-16 in ASD or LRFD without setting up the calculation by hand makes that comparison practical rather than theoretical, and the result comes with the working attached.
- Υπολογιστής σύνδεσης Beam Splice
- Αριθμομηχανή μπουλονιών
- Σχεδιασμός Βιδωμένης Σύνδεσης
- Υπολογιστής σύνδεσης Chevron Brace
- Υπολογιστής σύνδεσης διπλής γωνίας
- Υπολογιστής σύνδεσης τελικής πλάκας
- Υπολογιστής σύνδεσης φλάντζας
- Υπολογιστής σύνδεσης γονάτου
- Υπολογιστής μονής γωνίας σύνδεσης
- Υπολογιστής σύνδεσης μονής πλάκας
- SkyCiv Connection Design Vs. Στατική ιδέα
- SkyCiv Connection Design Vs. Σύνδεση Ram
- Υπολογιστής συγκόλλησης
- Σχεδιασμός Συγκολλημένης Σύνδεσης
Common questions about moment connections and how they are checked.
Απαντήθηκαν οι ερωτήσεις σας
Διαισθητική διασύνδεση
Μας είναι εύκολο να μάθουμε, ισχυρό στη χρήση, Η διαισθητική διεπαφή σάς επιτρέπει να έχετε γρήγορη πρόσβαση σε όλες τις λειτουργίες που χρειάζεστε. Γεμάτο με έξυπνες λειτουργίες όπως το εργαλείο στυλό, Επανάληψη / Καθρέφτης, και Μαζική επεξεργασία. Το περιεχόμενό σας πηγαίνει εδώ
Ολοκληρωμένη Υποστήριξη Κώδικα Σχεδιασμού
Το λογισμικό μας υποστηρίζει μια ολοκληρωμένη σειρά από χάλυβα, ξύλο, και συγκεκριμένοι κώδικες σχεδιασμού συμπεριλαμβανομένου του AISC, ΣΕ, AISI, NDS, ΟΠΩΣ ΚΑΙ, και CSA.
Τεχνολογία API
Το SkyCiv είναι μια προσαρμοσμένη λύση που διαθέτει απρόσκοπτες ενσωματώσεις, εύκολες υλοποιήσεις, αυτοματοποιημένες αναφορές και επεκτάσιμη σχεδίαση και αρχιτεκτονική.
24/7 Υποστήριξη πελατών
Το SkyCiv είναι μια προσαρμοσμένη λύση που διαθέτει απρόσκοπτες ενσωματώσεις, εύκολες υλοποιήσεις, αυτοματοποιημένες αναφορές και επεκτάσιμη σχεδίαση και αρχιτεκτονική.