Streifenfundament-Rechner

The SkyCiv Strip Footing Calculator should be used for the analysis and design of strip footings based on the ACI 318-19 Design Standard. The checks used in the calculator follow the requirements of Chapter 13 of the ACI Code related to strip footings. The strip footing design tool can deal either with reinforced concrete footings and also with mass concrete footings according to the requirements of Chapter 14 of the ACI 318 Standard.

Starting SkyCiv Strip Footing Capacity Calculator...

Entdecken Sie weitere Tools in unserer Quick-Design-Bibliothek

Durchsuchen Sie die vollständige Bibliothek

About the SkyCiv Strip Footing Design Calculator

How does the Strip Footing Calculator work?

The general procedure used in the Strip Footing Design tool agrees with the "Design Guide on the ACI 318 Bauvorschriften für Konstruktionsbeton" of the Concrete Reinforcing Steel Institute CRSI (2020). Some equations developed there are referenced to this guide in places where the Code has not a specific reference. The tool considers also the stability checks for soil bearing, maximum eccentricity, umkippen, and sliding checks. It is always desirable to avoid concentration of stresses in the soil and thus the program has a warning status when the resultant is outside the middle third of the footing. In solchen Fällen, the user is advised to enlarge the footing to have a better distribution of stresses.

The calculator allows the use of lateral loads (shear and moment) and it can deal with three load cases (Eigengewicht, Nutzlast, and wind or any other lateral load case). The user should check the used load combination factors of the table and add or modify them accordingly to the adopted load code. This tool works with imperial units. Standardmäßig, the tool works with net soil stresses and does not consider the footing's own weight and overburden soil pressure. It offers, jedoch, the option to consider the overburdened soil and footing weight and in this case, it will be working with gross stresses.

The ACI Strip Footing calculator can deal with the eccentricity of the wall about the footing base. Jedoch, for large eccentricities special measures may be needed like the implementation of negative reinforcement and the consideration of the overburden pressure in the strength design. These special measures are out of the scope of the tool.

How to use the Wall Footing Calculator?

The wall footing tool works with a try-and-error philosophy. The user can modify the input data until all checks will pass. Normally when there are failures, the solution involves enlarging the footing or incrementing the reinforcement. In any case, the tool also checks minimum and maximum conditions that help avoid excessive reinforcement. It is suggested to enlarge the height for shear failures, enlarge the width for stability failures, and increment the reinforcement area for bending failures when the footing height and shear checks are OK.

Häufig gestellte Fragen

  • What foundation-soil friction angle should be used?
    • This angle is normally between one-half and two-thirds of the soil friction angle. ("Grundlagen des Grundbaus" from Braja M. Das)
  • Which reduction factors are used in the strength verifications?
    • The ACI strip footing calculator uses φ = 0.75 für Scherung, φ = 0.90 zum Biegen (for reinforced concrete assuming a tension-controlled condition involving a reinforcement area that is less the maximum limit for this condition), φ = 0.60 for plain concrete bending, and φ = 0.65 for bearing.
  • What value is used for concrete unit weight ?
    • The default value used is 150 lb/ft3 as suggested by the standard for normal-weight concrete.
  • What value of soil unit weight can be used?
    • The common values are between 90 zu 130 lb/ft3. It is advised to use the humid value suggested in the geotechnical report of the project.
  • Is the wall reinforcement used for in calculations?
    • It is not used, only for drawing purposes. The wall dowels, jedoch, are used in the load forces transfer check.
  • Why does my footing have a small maximum spacing?
    • Der ACI 318-19 Sektion 24.3.2 specifies quite low values considering the values used for the concrete cover (normally around 3 Zoll). Einige Referenzen (Avoiding Problematic Uses of Slabs on Ground, Jan., 2021 Structure Magazine By Alexander Newman, SPORT., F.) mention that the ACI should consider exempting these provisions for footings and slabs on ground, aber, as of now, they still apply, and therefore they are included in the program.
Jetzt kostenlos starten

Über SkyCiv

SkyCiv bietet eine breite Palette an Cloud-Strukturanalyse- und Entwurfssoftware für Ingenieure. Als ein sich ständig weiterentwickelndes Technologieunternehmen sind wir bestrebt, bestehende Arbeitsabläufe zu erneuern und zu hinterfragen, um Ingenieuren bei ihren Arbeitsprozessen und Entwürfen Zeit zu sparen.

SkyCiv-Schnelldesign

Fire resistance calculator

Ihr ultimativer Werkzeugkasten für technisches Design. Erhalten Sie sofortigen Zugriff auf eine Bibliothek mit 70+
Taschenrechner aus Stahl, Holz, Beton, bis hin zu Aluminium und mehr.

Erhalten Sie noch heute Zugang