Калькулятор ленточного фундамента
The SkyCiv Strip Footing Calculator should be used for the analysis and design of strip footings based on the ACI 318-19 Стандарт дизайна. The checks used in the calculator follow the requirements of Chapter 13 of the ACI Code related to strip footings. The strip footing design tool can deal either with reinforced concrete footings and also with mass concrete footings according to the requirements of Chapter 14 of the ACI 318 Стандартный.
About the SkyCiv Strip Footing Design Calculator
How does the Strip Footing Calculator work?
The general procedure used in the Strip Footing Design tool agrees with the "Design Guide on the ACI 318 Требования Строительных норм для конструкционного бетона" of the Concrete Reinforcing Steel Institute CRSI (2020). Some equations developed there are referenced to this guide in places where the Code has not a specific reference. The tool considers also the stability checks for soil bearing, maximum eccentricity, переворачивание, and sliding checks. It is always desirable to avoid concentration of stresses in the soil and thus the program has a warning status when the resultant is outside the middle third of the footing. В таких случаях, the user is advised to enlarge the footing to have a better distribution of stresses.
The calculator allows the use of lateral loads (shear and moment) and it can deal with three load cases (статическая нагрузка, живая нагрузка, and wind or any other lateral load case). The user should check the used load combination factors of the table and add or modify them accordingly to the adopted load code. This tool works with imperial units. По умолчанию, the tool works with net soil stresses and does not consider the footing's own weight and overburden soil pressure. It offers, тем не мение, the option to consider the overburdened soil and footing weight and in this case, it will be working with gross stresses.
The ACI Strip Footing calculator can deal with the eccentricity of the wall about the footing base. тем не мение, for large eccentricities special measures may be needed like the implementation of negative reinforcement and the consideration of the overburden pressure in the strength design. These special measures are out of the scope of the tool.
How to use the Wall Footing Calculator?
The wall footing tool works with a try-and-error philosophy. The user can modify the input data until all checks will pass. Normally when there are failures, the solution involves enlarging the footing or incrementing the reinforcement. In any case, the tool also checks minimum and maximum conditions that help avoid excessive reinforcement. It is suggested to enlarge the height for shear failures, enlarge the width for stability failures, and increment the reinforcement area for bending failures when the footing height and shear checks are OK.
Часто задаваемые вопросы
- What foundation-soil friction angle should be used?
- This angle is normally between one-half and two-thirds of the soil friction angle. ("также применим для расчета несущей способности свай в глине" from Braja M. также применим для расчета несущей способности свай в глине)
- Which reduction factors are used in the strength verifications?
- The ACI strip footing calculator uses φ = 0.75 Однако одно важное отличие, которое вызывает введение различных материалов, - это движение нейтральной оси от центра тяжести., φ = 0.90 Однако одно важное отличие, которое вызывает введение различных материалов, - это движение нейтральной оси от центра тяжести. (for reinforced concrete assuming a tension-controlled condition involving a reinforcement area that is less the maximum limit for this condition), φ = 0.60 for plain concrete bending, and φ = 0.65 for bearing.
- What value is used for concrete unit weight ?
- The default value used is 150 lb/ft3 as suggested by the standard for normal-weight concrete.
- What value of soil unit weight can be used?
- The common values are between 90 в 130 lb/ft3. It is advised to use the humid value suggested in the geotechnical report of the project.
- Is the wall reinforcement used for in calculations?
- It is not used, only for drawing purposes. The wall dowels, тем не мение, are used in the load forces transfer check.
- Why does my footing have a small maximum spacing?
- МСА 318-19 Раздел 24.3.2 specifies quite low values considering the values used for the concrete cover (normally around 3 дюймов). Некоторые ссылки (Avoiding Problematic Uses of Slabs on Ground, Янв, 2021 Structure Magazine By Alexander Newman, Возможная ошибка, Ф.) mention that the ACI should consider exempting these provisions for footings and slabs on ground, но, as of now, they still apply, and therefore they are included in the program.
О SkyCiv
SkyCiv предлагает широкий спектр программного обеспечения для анализа и проектирования облачных вычислений для инженеров. Как постоянно развивающаяся технологическая компания, мы стремимся к инновациям и стимулированию существующих рабочих процессов, чтобы сэкономить время инженеров в их рабочих процессах и проектах.