Plant Structure

AISC360 Design

Project Description

This 360-member steel structure is the wireframe of a industrial building mocked up for design. The structure, built out of mostly I Beam and HSS sections, passed AISC 360-10 requirements under a 10 load cominations, loaded from ASCE 7-10. On of the major challenges in this design was the lack of lateral bracing on the South faces of the roof truss, which would deflect excessively under wind loadings.

Project Details

  • Date May 24, 2017
  • Tags Civil & Construction

Related Projects